SOR-2016-311 Energy Efficiency Regulations, 2016

Current to 2026-04-28 · last amended 2025-10-09

Contents

Whereas, pursuant to section 26 of the Energy Efficiency Act a, a copy of the proposed Energy Efficiency Regulations, 2016, substantially in the annexed form, was published in the Canada Gazette, Part I, on April 30, 2016; S.C. 1992, c. 36

Therefore, His Excellency the Governor General in Council, on the recommendation of the Minister of Natural Resources, pursuant to sections 20 b and 25 of the Energy Efficiency Act a, makes the annexed Energy Efficiency Regulations, 2016. S.C. 2009, c. 8, s. 5

Interpretation

s. 1 — Definitions

The following definitions apply in these Regulations.

Act means the Energy Efficiency Act. (Loi)

adhesive tag means a label that is attached to an energy-using product by at least two strips of adhesive that are located on opposite edges of the label. (étiquette adhésive)

AHRI means the Air-Conditioning, Heating and Refrigeration Institute. (AHRI)

ANSI means the American National Standards Institute. (ANSI)

ASHRAE means the American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc. (ASHRAE)

CGA means the Canadian Gas Association. (ACG)

CIE means the International Commission on Illumination. (CIE)

CSA means the Canadian Standards Association. (CSA)

flap tag means a label whose top edge is attached to an energy-using product by one strip of adhesive. (vignette)

hang tag means a label that is attached to an energy-using product by material that is looped around a section of the product so that the label hangs freely from the product. (étiquette volante)

household means manufactured or sold primarily for use in a dwelling. (domestique)

IEC means the International Electrotechnical Commission. (CEI)

IEEE means the Institute of Electrical and Electronics Engineers. (IEEE)

IES means the Illuminating Engineering Society of North America. (IES)

mains power means an alternating current electric power source that is in a building and is less than or equal to a nominal 240-volt single-phase supply. (alimentation principale)

model number means, in respect of any model of an energy-using product, the designator that is assigned to that model for the purposes of these Regulations and that distinguishes it from similar models. (numéro de modèle)

NEMA means the National Electrical Manufacturers Association. (NEMA)

new Regulations[Repealed, SOR/2025-110, s. 1]

unique motor identifier means an identifier consisting of the information set out below, in the following sequence:

the name of the manufacturer, in abbreviated form;

the nominal power of the motor, expressed in kilowatts for an IEC design motor or in horsepower for a NEMA design motor;

the number of poles; and

a statement as to whether the motor is of open or enclosed construction. (identificateur unique du moteur)

s. 1(2) — Reference to energy-using product

In these Regulations, a reference to an energy-using product is a reference to that product as defined in the Division or Subdivision associated with it.

s. 1(3) — Incorporated standards

In these Regulations, a reference to an AHRI, ANSI, ASHRAE, CGA, CIE, CSA, IEC, IEEE, IES or NEMA standard or to a technical standards document is to be read as a reference to the standard or technical standards document as amended from time to time.

s. 1(4) — Exception — test procedure waivers

In these Regulations, a reference to a testing standard that is incorporated by reference does not include any test procedure waiver that may be set out in that standard.

s. 1.1 — Standards and procedures of other jurisdiction incorporated by reference

Despite these Regulations, if an energy efficiency standard or test procedure that is incorporated by reference in these Regulations as amended from time to time is a reference to a standard or test procedure set out in the laws of another jurisdiction and that standard or procedure is subsequently repealed or revoked in that other jurisdiction, the reference to the standard or procedure in these Regulations is deemed to be a reference to that standard or procedure as it read on the day before the day on which it was repealed or revoked and it continues to apply for the purposes of these Regulations.

General

Interpretation

s. 2 — Definitions

The following definitions apply in this Part.

certification body means, in respect of an energy-using product, a body that is accredited by the Standards Council of Canada to operate a certification program in respect of the energy efficiency of the product. (organisme de certification)

verification mark means, in respect of an energy-using product, a mark that is

issued by a certification body to signify that the body has

determined that the product complies with the applicable energy efficiency standard, and

if the product is one for which information must be provided to the Minister for the purpose of subsection 5(1) of the Act, verified the information that is related to the product’s energy performance; or

issued by a province to signify that the product complies with the province’s energy efficiency standard. (marque de vérification)

s. 3 — Incorporated products

Unless otherwise specified by these Regulations, an energy-using product that is incorporated into another product remains an energy-using product for the purposes of these Regulations even if the other product is not an energy-using product.

Verification Mark

s. 4 — Verification mark

Subject to subsection (4), every energy-using product that, for the purpose of sale or lease, is shipped from one province to another or imported into Canada must be labelled with a verification mark that is issued by

a certification body; or

a province whose energy efficiency standard for the product is equivalent to or exceeds the energy efficiency standard prescribed for the product in these Regulations.

s. 4(2) — Location and visibility

The verification mark must be readily visible on the surface of the energy-using product. However, in respect of the following energy-using products, the verification mark may be on the exterior of the product’s package:

[Repealed]

a general service lamp;

[Repealed]

a general service fluorescent lamp;

[Repealed]

a battery charger;

an external power supply; and

a faucet that is a replacement aerator.

[Repealed]

s. 4(4) — Exception — external power supplies

An external power supply is not required to be labelled with a verification mark if

it is labelled with a mark in accordance with the U.S. Department of Energy publication entitled “International Efficiency Marking Protocol for External Power Supplies”, as amended from time to time;

a certification body has verified the information related to the product’s energy performance that is provided to the Minister for the purpose of subsection 5(1) of the Act; and

it is labelled with the same model number as that used when the information was verified.

[Repealed]

Provision of Information

s. 5 — Prescribed information

A dealer who, for the purpose of sale or lease, ships an energy-using product from one province to another or imports an energy-using product into Canada must, for the purpose of subsection 5(1) of the Act, provide the following information to the Minister:

the name of the product as prescribed in these Regulations;

the brand name of the product, if any;

the product’s model number or, in the case of a motor, the product’s model number or unique motor identifier;

the name of the product’s manufacturer;

one of the following, namely,

the name of the certification body or province whose verification mark will be on the product or its package, or

[Repealed]

in the case of an external power supply, the name of the certification body referred to in paragraph 4(4)(b);

[Repealed]

any other information that is prescribed in these Regulations to be provided to the Minister for the purpose of subsection 5(1) of the Act; and

information that indicates whether a mathematical model described in subsection (3) was used to generate any of the information provided under paragraph (f).

s. 5(2) — Manner and time

The information must be provided electronically or by fax, hand delivery, courier or mail before the product is imported into Canada or shipped from one province to another.

s. 5(3) — Mathematical model

Despite any provision in these Regulations requiring that the information referred to in this section be collected in accordance with an identified standard, a dealer may instead provide the information as generated by a mathematical model that, by means of an engineering or statistical analysis or a computer simulation or model, emulates the manner in which the information is collected under the identified standard.

[Repealed]

Information Pertaining to Imports

s. 7 — Prescribed information

A dealer who, for the purpose of sale or lease, imports an energy-using product into Canada must, for the purpose of subsection 5(1) of the Act, provide the following information to the Minister:

the name of the product as prescribed in these Regulations;

the brand name of the product, if any;

the product’s model number or, in the case of a motor, the product’s model number or unique motor identifier;

the dealer’s address; and

a statement as to whether the product is being imported

for sale or lease in Canada without modification,

for sale or lease in Canada after being modified to comply with the applicable energy efficiency standard, or

for incorporation into any other product that is to be exported from Canada.

s. 7(1.1) — Exception

However, the following energy-using products are not energy-using products for the purpose of subsection (1) if, at the time of their importation, they are incorporated into another product:

a battery charger;

an external power supply;

a fluorescent lamp ballast;

an electric motor; and

a small electric motor.

s. 7(2) — Manner and time

The information must be provided by including it in any customs invoice or commercial invoice that is required to be provided in respect of the energy-using product under subsection 6(1) of the Accounting for Imported Goods and Payment of Duties Regulations and must be provided before the product is released under the Customs Act.

Exemptions from Certain Provisions of the Act

s. 8 — Exemption — product to be modified

A dealer is exempt from the application of paragraph 4(1)(a) of the Act if the dealer, for the purpose of modifying an energy-using product to comply with the applicable energy efficiency standard, ships the product from the province in which it was manufactured to another province or imports the product into Canada.

s. 8(2) — Requirements

The dealer must

ensure that the product is brought into compliance with the applicable energy efficiency standard within 90 days after the day on which the product is shipped or imported;

despite subsection 5(2), provide the information referred to in subsection 5(1) within 120 days after the day on which the product is shipped or imported; and

if requested by the Minister, provide the Minister with any other information that is necessary to establish that the product has been brought into compliance with the applicable energy efficiency standard.

s. 9 — Exemption — incorporation into product for export

A dealer is exempt from the application of sections 4 and 5 of the Act with respect to the shipment or importation of an energy-using product that is to be incorporated into any other product that is to be exported from Canada.

s. 10 — Exemption — product to be exported

A dealer is exempt from the application of sections 4 and 5 of the Act if the dealer, for the purpose of exporting the energy-using product from Canada, ships the product from the province in which it was manufactured to another province or imports the product into Canada.

s. 11 — Exemption — motors with same unique motor identifier

A dealer is exempt from the application of section 5 of the Act in respect of a motor if

the information has been provided in respect of a motor that has the same unique motor identifier; and

the motor is at least as energy efficient as the motor for which the information was provided.

Specified Energy-Using Products

s. 11.1 — Subsection 20.1(2) of Act

The following energy-using products are specified for the purpose of subsection 20.1(2) of the Act:

clothes dryers;

clothes washers;

integrated clothes washer-dryers;

dishwashers;

refrigerators and combination refrigerator-freezers;

freezers;

gas ranges;

dehumidifiers;

microwave ovens;

miscellaneous refrigeration products;

ceiling fans;

room air conditioners;

large air conditioners;

packaged terminal air conditioners;

single package central air conditioners;

single package vertical air conditioners;

split system central air conditioners;

portable air conditioners;

large heat pumps;

packaged terminal heat pumps;

single package central heat pumps;

single package vertical heat pumps;

split system central heat pumps;

gas furnaces;

oil-fired furnaces;

electric furnaces;

gas boilers;

oil-fired boilers;

electric boilers;

gas-fired storage water heaters;

oil-fired water heaters;

electric water heaters;

gas-fired instantaneous water heaters;

general service lamps;

[Repealed]

[Repealed]

general service fluorescent lamps;

fluorescent lamp ballasts;

metal halide lamp ballasts;

torchieres;

ceiling fan light kits;

exit signs;

traffic signal modules;

pedestrian modules;

external power supplies;

battery chargers;

line voltage thermostats;

commercial refrigerators;

commercial refrigerator-freezers;

commercial freezers;

refrigerated beverage vending machines;

snack and refrigerated beverage vending machines;

ice-makers;

walk-in door assemblies;

walk-in panels;

walk-in refrigeration systems;

dry-type transformers;

electric motors;

small electric motors;

faucets;

showerheads;

commercial pre-rinse spray valves;

clean water pumps;

pool pumps; and

air compressors.

Energy-Using Products

Household Appliances

Interpretation

s. 12 — Definitions

The following definitions apply in this Division.

10 C.F.R. Appendix D2 means Appendix D2 to Subpart B, Part 430 of Title 10 to the United States Code of Federal Regulations, entitled Uniform Test Method for Measuring the Energy Consumption of Clothes Dryers, as amended from time to time. (appendice D2 10 C.F.R.)

CSA C300-00[Repealed, SOR/2019-163, s. 1]

CSA C300-12 means the CSA standard CAN/CSA-C300-12 entitled Energy Performance and Capacity of Household Refrigerators, Refrigerator-Freezers, Freezers and Wine Chillers. (CSA C300-12)

CSA C300-15 means the CSA standard CAN/CSA-C300-15 entitled Energy Performance and Capacity of Household Refrigerators, Refrigerator-Freezers, Freezers and Wine Chillers. (CSA C300-15)

CSA C358-03 means the CSA standard CAN/CSA-C358-03 entitled Energy Consumption Test Methods for Household Electric Ranges. (CSA C358-03)

CSA C360-03 means the CSA standard CAN/CSA-C360-03 entitled Energy Performance, Water Consumption and Capacity of Household Clothes Washers. (CSA C360-03)

CSA C360-13 means the CSA standard CAN/CSA-C360-13 entitled Energy Performance, Water Consumption and Capacity of Household Clothes Washers. (CSA C360-13)

CSA C361-12[Repealed, SOR/2018-201, s. 5]

CSA C361-16 means the CSA standard CAN/CSA-C361-16 entitled Energy performance and drum volume of household electric clothes dryers. (CSA C361-16)

CSA C361-92 means the CSA standard CAN/CSA-C361-92 entitled Test Method for Measuring Energy Consumption and Drum Volume of Electrically Heated Household Tumble-Type Clothes Dryers. (CSA C361-92)

Labelling

s. 13 — EnerGuide label

An energy-using product prescribed in any of Subdivisions A to G or K of this Division must be labelled in the form set out in Schedule 1.

s. 13(2) — Manner of labelling

The label must be an adhesive tag, flap tag or hang tag that is attached to the product so that the tag is readily visible when the product is viewed from the front.

s. 14 — Paper — adhesive and flap tags

The paper that is used for adhesive tags or flap tags must weigh, exclusive of the release liner and adhesive, not less than the equivalent of 26.31 kg (58 pounds) per 500 sheets measuring 63.5 cm (25 inches) by 96.52 cm (38 inches).

s. 14(2) — Adhesive — adhesive and flap tags

The adhesive that is used to attach an adhesive tag or a flap tag to an energy-using product must

render the tag easily removable from the product without the use of a tool or any liquid other than water; and

have an adhesion capacity that is sufficient to prevent the tag from being dislodged from the product under normal handling conditions.

s. 15 — Paper — hang tags

The paper that is used for hang tags must weigh not less than the equivalent of 49.9 kg (110 pounds) per 500 sheets measuring 64.77 cm (25.5 inches) by 77.47 cm (30.5 inches).

s. 15(2) — Attachment material — hang tags

The material that is used to attach a hang tag to an energy-using product must be of sufficient strength to ensure that when gradual pressure is applied to the tag by pulling it away from the product, the tag will tear before the material breaks.

Clothes Dryers

s. 16 — Definition of clothes dryer

In this Subdivision, clothes dryer means a household tumble-type clothes dryer that is electrically operated.

s. 17 — Size category

For the purposes of these Regulations, the size category of a clothes dryer is

compact, if it has a drum capacity of less than 125 L (4.4 cubic feet); or

standard, if it has a drum capacity of 125 L (4.4 cubic feet) or more.

s. 18 — Energy-using product

A clothes dryer is prescribed as an energy-using product.

s. 18(2) — Limit

However, for the purposes of sections 4, 5, 13 to 15 and 19, a clothes dryer is not considered to be an energy-using product unless it is manufactured on or after February 3, 1995.

s. 19 — Energy efficiency standards

The energy efficiency standards set out in column 2 of the table to this section apply to clothes dryers that are manufactured during the periods set out in column 3.

s. 19(2) — Testing standard

A clothes dryer complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by the standard set out in column 1 that are applicable to a clothes dryer as defined in section 16. TABLE Column 1 Column 2 Column 3 Item Testing Standard Energy Efficiency Standard Period of Manufacture 1 CSA C361-92 CSA C361-92, Table 8.1 On or after February 3, 1995 and before January 1, 2015 2 CSA C361-16 or 10 C.F.R. Appendix D2 CSA C361-16, Table 1 On or after January 1, 2015

s. 20 — Information

For the purpose of subsection 5(1) of the Act, the information set out in column 3 of the table to this section must be collected in accordance with the standard set out in column 2 and provided to the Minister in respect of a clothes dryer described in column 1. TABLE Column 1 Column 2 Column 3 Item Energy-using Product Testing Standard Information 1 Clothes dryers manufactured on or after February 3, 1995 and before January 1, 2015 CSA C361-92 2 Clothes dryers manufactured on or after January 1, 2015 CSA C361-16 or 10 C.F.R. Appendix D2

Clothes Washers

s. 21 — Definition of clothes washer

In this Subdivision, clothes washer means an electrically operated clothes washer that does not require mechanical fastening to a floor or wall, is top- or front-loaded and has an internal control system that regulates the water temperature without the need for user intervention after the machine is set in operation.

s. 22 — Size category

For the purposes of these Regulations, the size category of a clothes washer is

compact, if it has a container capacity of less than 45 L (1.6 cubic feet); or

standard, if it has a container capacity of 45 L (1.6 cubic feet) or more.

s. 23 — Energy-using product

A clothes washer is prescribed as an energy-using product.

s. 23(2) — Limits

However, a clothes washer is not considered to be an energy-using product

for the purposes of sections 4, 5 and 24, unless it is manufactured on or after February 3, 1995; and

for the purposes of sections 13 to 15, unless it is a household clothes washer and it is manufactured on or after February 3, 1995.

s. 24 — Energy efficiency standards

The energy efficiency standards set out in column 3 of the table to this section apply to clothes washers described in column 1 that are manufactured during the periods set out in column 4.

s. 24(2) — Testing standard

A clothes washer complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by the standard set out in column 2 that are applicable to a clothes washer as defined in section 21. TABLE Column 1 Column 2 Column 3 Column 4 Item Energy-using Product Testing Standard Energy Efficiency Standard Period of Manufacture 1 Clothes washers CSA C360-03 CSA C360-03, Table 9 On or after February 3, 1995 and before January 1, 2007 2 Clothes washers, other than household clothes washers CSA C360-03 CSA C360-03, Table 10 On or after January 1, 2007 and before January 8, 2013 3 Clothes washers, other than household clothes washers CSA C360-03 CSA C360-13, Table 11 On or after January 8, 2013 and before January 1, 2018 4 Clothes washers that are top-loaded, other than household clothes washers CSA C360-13 On or after January 1, 2018 5 Clothes washers that are front-loaded, other than household clothes washers CSA C360-13 On or after January 1, 2018 6 Household clothes washers CSA C360-03 CSA C360-03, Table 10 On or after January 1, 2007 and before March 7, 2015 7 Household clothes washers CSA C360-13 CSA C360-13, Table 9 On or after March 7, 2015 and before January 1, 2018 8 Household clothes washers CSA C360-13 CSA C360-13, Table 10 On or after January 1, 2018

s. 25 — Information

For the purpose of subsection 5(1) of the Act, the information set out in column 3 of the table to this section must be collected in accordance with the standard set out in column 2 and provided to the Minister in respect of a clothes washer described in column 1. TABLE Column 1 Column 2 Column 3 Item Energy-using Product Testing Standard Information 1 Clothes washers manufactured on or after February 3, 1995 and before March 7, 2015 CSA C360-03 2 Household clothes washers manufactured on or after March 7, 2015 CSA C360-13 3 Clothes washers, other than household clothes washers, manufactured on or after March 7, 2015 and before January 1, 2018 CSA C360-03 4 Clothes washers, other than household clothes washers, manufactured on or after January 1, 2018 CSA C360-13

Integrated Clothes Washer-Dryers

s. 26 — Definitions

The following definitions apply in this Subdivision.

combination clothes washer-dryer means a household appliance that has

a clothes washer function and clothes dryer function that utilize the same drum;

a common control panel for both functions; and

one power source. (laveuse-sécheuse combinée)

integrated clothes washer-dryer means

a household appliance that consists of a clothes washer component and a clothes dryer component located above, below or beside it, that is powered by one power source and that has its control panel located on one of the components; or

a combination clothes washer-dryer. (laveuse-sécheuse)

V means

in the case of an integrated clothes washer-dryer that is not a combination clothes washer-dryer, the volumes, expressed in litres, of the basket for the clothes washer component and of the drum for the clothes dryer component; or

in the case of an integrated clothes washer-dryer that is a combination clothes washer-dryer, the volume, expressed in litres, of the drum. (V)

s. 27 — Size category — other than combination clothes washer-dryer

For the purposes of these Regulations, the size category of an integrated clothes washer-dryer that is not a combination clothes washer-dryer is

compact, if it has a clothes dryer component with a drum capacity of less than 125 L (4.4 cubic feet) and a clothes washer component with a basket capacity of less than 45 L (1.6 cubic feet); or

standard, if it has a clothes dryer component with a drum capacity of 125 L (4.4 cubic feet) or more and a clothes washer component with a basket capacity of 45 L (1.6 cubic feet) or more.

s. 27(2) — Size category — combination clothes washer-dryer

For the purposes of these Regulations, the size category of an integrated clothes washer-dryer that is a combination clothes washer is

compact, if it has a drum capacity of less than 45 L (1.6 cubic feet); or

standard, if it has a drum capacity of 45 L (1.6 cubic feet) or more.

s. 28 — Type

For the purposes of these Regulations, an integrated clothes washer-dryer is one of the following types, namely, combination, over/under or side-by-side.

s. 29 — Energy-using product

An integrated clothes washer-dryer is prescribed as an energy-using product.

s. 29(2) — Limit

However, for the purposes of sections 4, 5, 13 to 15 and 30, an integrated clothes washer-dryer is not considered to be an energy-using product unless it is manufactured on or after February 3, 1995.

s. 30 — Energy efficiency standards

The energy efficiency standards set out in column 2 of the table to this section apply to integrated clothes washer-dryers that are manufactured during the periods set out in column 3.

s. 30(2) — Testing standard

An integrated clothes washer-dryer complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by the standard set out in column 1 that are applicable to an integrated clothes washer-dryer as defined in section 26. TABLE Column 1 Column 2 Column 3 Item Testing Standard Energy Efficiency Standard Period of Manufacture 1 On or after February 3, 1995 and before January 1, 2007 2 On or after January 1, 2007 and before March 7, 2015 3 On or after March 7, 2015 and before January 1, 2018 4 On or after January 1, 2018

s. 31 — Information

For the purpose of subsection 5(1) of the Act, the information set out in column 3 of the table to this section must be collected in accordance with the standard set out in column 2 and provided to the Minister in respect of an integrated clothes washer-dryer described in column 1. TABLE Column 1 Column 2 Column 3 Item Energy-using Product Testing Standard Information 1 Integrated clothes washer-dryers manufactured on or after February 3, 1995 and before March 7, 2015 2 Integrated clothes washer-dryers manufactured on or after March 7, 2015

Dishwashers

s. 32 — Definitions

The following definitions apply in this Subdivision.

CSA C373-04 means the CSA standard CAN/CSA-C373-04 entitled Energy Consumption Test Methods and Limits for Household Dishwashers. (CSA C373-04)

CSA C373-14 means the CSA standard CAN/CSA-C373-14 entitled Energy Performance and Water Consumption of Household Dishwashers. (CSA C373-14)

dishwasher means an electrically operated automatic household dishwasher. (lave-vaisselle)

s. 33 — Size category

For the purposes of these Regulations, the size category of a dishwasher is

compact, if it has a capacity of less than eight place settings and six serving pieces; or

standard, if it has a capacity that is equal to or greater than eight place settings and six serving pieces.

s. 34 — Type

For the purposes of these Regulations, a dishwasher is one of the following types:

built-in, if it is designed to be permanently connected to a water and electric supply in a dwelling; or

portable, if it is designed not to be permanently connected to a water and electric supply in a dwelling.

s. 35 — Labelling — total annual energy consumption

In respect of a dishwasher that is manufactured on or after January 1, 2010, a reference to “annual energy consumption” in Schedule 1 is to be read as a reference to “total annual energy consumption”.

s. 36 — Energy-using product

A dishwasher is prescribed as an energy-using product.

s. 36(2) — Limit

However, for the purposes of sections 4, 5, 13 to 15 and 37, a dishwasher is not considered to be an energy-using product unless it is manufactured on or after February 3, 1995.

s. 37 — Energy efficiency standards

The energy efficiency standards set out in column 3 of the table to this section apply to dishwashers described in column 1 that are manufactured during the periods set out in column 4.

s. 37(2) — Testing standard

A dishwasher complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by the standard set out in column 2 that are applicable to a dishwasher as defined in section 32. TABLE Column 1 Column 2 Column 3 Column 4 Item Energy-using Product Testing Standard Energy Efficiency Standard Period of Manufacture 1 Dishwashers CSA C373-04 CSA C373-04, Table 2 On or after February 3, 1995 and before January 1, 2010 2 Dishwashers that are standard CSA C373-04 Total annual energy consumption ≤ 355 kWh On or after January 1, 2010 and before May 30, 2013 3[Repealed, SOR/2018-201, s. 11] 4 Dishwashers that are compact CSA C373-04 Total annual energy consumption ≤ 260 kWh On or after January 1, 2010 and before May 30, 2013 5 Dishwashers CSA C373-14 CSA C373-14, Table 2 On or after May 30, 2013

s. 38 — Information

For the purpose of subsection 5(1) of the Act, the information set out in column 3 of the table to this section must be collected and provided to the Minister in respect of a dishwasher described in column 1 and, if applicable, the information must be collected in accordance with the standard set out in column 2. TABLE Column 1 Column 2 Column 3 Item Energy-using Product Testing Standard Information 1 Dishwashers manufactured on or after February 3, 1995 and before January 1, 2010 CSA C373-04, for information set out in paragraphs (b) to (d) 2 Dishwashers manufactured on or after January 1, 2010 and before May 30, 2013 CSA C373-04, for information set out in paragraphs (b) to (e) 3 Dishwashers manufactured on or after May 30, 2013 CSA C373-14, for information set out in paragraphs (b) to (d) and (f)

Refrigerators and Combination Refrigerator-Freezers

s. 39 — Definitions

The following definitions apply in this Subdivision.

combination refrigerator-freezer means a household combination refrigerator-freezer that has a defrost system, including a compressor-cycled automatic defrost system and a capacity of 1 105 L (39 cubic feet) or less. (réfrigérateur-congélateur)

compressor-cycled automatic defrost system means a defrost system in which the defrosting action for the refrigerated spaces occurs using the natural warming of the evaporator and that is automatically initiated when the compressor is cycled on and automatically terminated when the compressor is cycled off. (dispositif de dégivrage automatique à cycle du compresseur)

refrigerator means a household refrigerator that has a capacity of 1 105 L (39 cubic feet) or less and that has a defrost system, including a compressor-cycled automatic defrost system. It does not include

a household refrigerator that uses an absorption refrigeration system; or

a miscellaneous refrigeration product. (réfrigérateur)

Type 5A combination refrigerator-freezer[Repealed, SOR/2019-163, s. 3]

s. 40 — Size category

For the purposes of these Regulations, the size category of a refrigerator or combination refrigerator-freezer is the capacity range set out below within which the actual size of the product falls or that is closest to the actual size of the product:

less than 70 L (2.5 cubic feet);

70 to 126 L (2.5 to 4.4 cubic feet);

127 to 182 L (4.5 to 6.4 cubic feet);

183 to 239 L (6.5 to 8.4 cubic feet);

240 to 295 L (8.5 to 10.4 cubic feet);

296 to 352 L (10.5 to 12.4 cubic feet);

353 to 409 L (12.5 to 14.4 cubic feet);

410 to 465 L (14.5 to 16.4 cubic feet);

466 to 522 L (16.5 to 18.4 cubic feet);

523 to 579 L (18.5 to 20.4 cubic feet);

580 to 635 L (20.5 to 22.4 cubic feet);

636 to 692 L (22.5 to 24.4 cubic feet);

693 to 748 L (24.5 to 26.4 cubic feet);

749 to 805 L (26.5 to 28.4 cubic feet);

806 to 862 L (28.5 to 30.4 cubic feet); or

863 to 1 105 L (30.5 to 39.0 cubic feet).

s. 41 — Type

For the purposes of these Regulations, a refrigerator or combination refrigerator-freezer is one of the product types (1) to (7-BI) and (11) to (15I) of Table 1 to CSA C300-15.

s. 42 — Energy-using products

Refrigerators and combination refrigerator-freezers are prescribed as energy-using products.

s. 42(2) — Limit

However, for the purposes of sections 4, 5, 13 to 15 and 43, a refrigerator or combination refrigerator-freezer is not considered to be an energy-using product unless it is manufactured on or after February 3, 1995.

s. 43 — Energy efficiency standards

The energy efficiency standards set out in column 3 of the table to this section apply to refrigerators and combination refrigerator-freezers described in column 1 that are manufactured during the periods set out in column 4.

s. 43(2) — Testing standard — refrigerators

A refrigerator complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by the standard set out in column 2 that are applicable to a refrigerator as defined in section 39.

s. 43(3) — Testing standard — combination-refrigerator freezers

A combination refrigerator-freezer complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by the standard set out in column 2 that are applicable to a combination-refrigerator freezer as defined in section 39. TABLE Item Column 1 Column 2 Column 3 Column 4 Energy-using Product Testing Standard Energy Efficiency Standard Period of Manufacture 1 Refrigerators and combination refrigerator-freezers CSA C300-12 CSA C300-12, Table 1 On or after February 3, 1995 and before September 15, 2014 2 Refrigerators and combination refrigerator-freezers CSA C300-15 CSA C300-15, Table 1 On or after September 15, 2014

s. 44 — Information

For the purpose of subsection 5(1) of the Act, the following information must be provided to the Minister in respect of a refrigerator or combination refrigerator-freezer:

its type;

the volume of its fresh food compartment;

the volume of its freezer compartment, if any;

its adjusted volume; and

its annual energy consumption, expressed in kilowatt hours.

s. 44(2) — Standard

The information must be collected in accordance with one of the following standards:

CSA C300-12, if the product was manufactured on or after February 3, 1995 and before September 15, 2014; or

CSA C300-15, if the product is manufactured on or after September 15, 2014.

[Repealed]

Freezers

s. 45 — Definition of freezer

In this Subdivision, freezer means a household freezer that has a capacity of 850 L (30 cubic feet) or less.

s. 46 — Size category

For the purposes of these Regulations, the size category of a freezer is the capacity range set out below within which the actual size of the product falls or that is closest to the actual size of the product:

less than 155 L (5.5 cubic feet);

155 to 210 L (5.5 to 7.4 cubic feet);

211 to 267 L (7.5 to 9.4 cubic feet);

268 to 324 L (9.5 to 11.4 cubic feet);

325 to 380 L (11.5 to 13.4 cubic feet);

381 to 437 L (13.5 to 15.4 cubic feet);

438 to 494 L (15.5 to 17.4 cubic feet);

495 to 550 L (17.5 to 19.4 cubic feet);

551 to 607 L (19.5 to 21.4 cubic feet);

608 to 664 L (21.5 to 23.4 cubic feet);

665 to 720 L (23.5 to 25.4 cubic feet);

721 to 777 L (25.5 to 27.4 cubic feet);

778 to 833 L (27.5 to 29.4 cubic feet); or

834 to 850 L (29.5 to 30.0 cubic feet).

s. 47 — Type

For the purposes of these Regulations, a freezer is one of the types described in the product types (8) to (10A) and (16) to (18) of Table 1 to CSA C300-15.

s. 48 — Energy-using product

A freezer is prescribed as an energy-using product.

s. 48(2) — Limit

However, for the purposes of sections 4, 5, 13 to 15 and 49, a freezer is not considered to be an energy-using product unless it is manufactured on or after February 3, 1995.

s. 49 — Energy efficiency standards

The energy efficiency standards set out in column 3 of the table to this section apply to freezers described in column 1 that are manufactured during the periods set out in column 4.

s. 49(2) — Testing standard

A freezer complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by the standard set out in column 2 that are applicable to a freezer as defined in section 45. TABLE Item Column 1 Column 2 Column 3 Column 4 Energy-using Product Testing Standard Energy Efficiency Standard Period of Manufacture 1 Freezers CSA C300-12 CSA C300-12, Table 1 On or after February 3, 1995 and before September 15, 2014 2 Freezers CSA C300-15 CSA C300-15, Table 1 On or after September 15, 2014

s. 50 — Information

For the purpose of subsection 5(1) of the Act, the following information must be provided to the Minister in respect of a freezer:

its type;

its total refrigerated volume;

its adjusted volume;

its annual energy consumption, expressed in kilowatt hours; and

its ice freezing capacity, expressed in kilograms per 24 hours.

s. 50(2) — Standard

The information must be collected in accordance with one of the following standards:

CSA C300-12, if the product was manufactured on or after February 3, 1995 and before September 15, 2014; or

CSA C300-15, if the product is manufactured on or after September 15, 2014.

[Repealed]

Electric Ranges

s. 51 — Definitions

The following definitions apply in this Subdivision.

conventional cooking top means a cooking top that is not a modular cooking top. (table de cuisson traditionnelle)

E means energy consumption, expressed in kilowatt hours per month. (E)

electric range means a household electric range. It does not include a portable range that is designed for an electrical supply of 120 V or a microwave oven. (cuisinière électrique)

modular cooking top means a cartridge that consists of at least one surface element and that can be plugged into a receptacle on the surface of an electric range. (table de cuisson modulaire)

s. 52 — Size category

For the purposes of these Regulations, the size category of an electric range that has at least one surface element and at least one oven is one of the following, based on the product’s exterior width:

60.96 cm (24 inches);

76.2 cm (30 inches);

91.44 cm (36 inches); or

121.92 cm (48 inches).

s. 53 — Type

For the purposes of these Regulations, an electric range is one of the following types:

if it has at least one oven, either self-cleaning or non-self-cleaning; and

if it has no oven, all models.

s. 54 — Energy-using product

An electric range is prescribed as an energy-using product.

s. 54(2) — Limit

However, for the purposes of sections 4, 5, 13 to 15 and 55, an electric range is not considered to be an energy-using product unless it is manufactured on or after February 3, 1995.

s. 55 — Energy efficiency standards

The energy efficiency standards set out in column 2 of the table to this section apply to electric ranges described in column 1 that are manufactured during the periods set out in column 3.

s. 55(2) — Testing standard

An electric range complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by CSA C358-03 that are applicable to an electric range as defined in section 51. TABLE Column 1 Column 2 Column 3 Item Energy-using Product Energy Efficiency Standard Period of Manufacture 1 Electric ranges that have at least one surface element and at least one oven E ≤ 0.93 V + 14.3 On or after February 3, 1995 and before August 1, 2003 2 Electric ranges that have at least one surface element and at least one oven CSA C358-03, clause 8(a) On or after August 1, 2003 3 Electric ranges that have at least one oven but no surface elements E ≤ 38 On or after February 3, 1995 and before August 1, 2003 4 Electric ranges that have at least one oven but no surface elements CSA C358-03, clause 8(c) On or after August 1, 2003 5 Electric ranges that are counter-mounted and have at least one surface element on a conventional cooking top but have no oven E ≤ 34 On or after February 3, 1995 and before August 1, 2003 6 Electric ranges that are counter-mounted and have at least one surface element on a modular cooking top but have no oven E ≤ 43 On or after February 3, 1995 and before August 1, 2003 7 Electric ranges that are counter-mounted and have at least one surface element but have no oven CSA C358-03, clause 8(b) On or after August 1, 2003

s. 56 — Information

For the purpose of subsection 5(1) of the Act, the information set out in column 2 of the table to this section must be collected in accordance with CSA C358-03 and provided to the Minister in respect of an electric range described in column 1. TABLE Column 1 Column 2 Item Energy-using Product Information 1 Electric ranges that have at least one surface element and at least one oven and that were manufactured on or after February 3, 1995 and before August 1, 2003 2 Electric ranges that have at least one surface element and at least one oven and that are manufactured on or after August 1, 2003 3 Electric ranges that have at least one oven but no surface element and that were manufactured on or after February 3, 1995 and before August 1, 2003 4 Electric ranges that have at least one oven but no surface element and that are manufactured on or after August 1, 2003 5 Electric ranges that are counter-mounted, have at least one surface element but no oven and were manufactured on or after February 3, 1995 and before August 1, 2003 6 Electric ranges that are counter-mounted, have at least one surface element but no oven and are manufactured on or after August 1, 2003

Gas Ranges

s. 57 — Definition of gas range

In this Subdivision, gas range means a household propane or natural gas range that has an electrical power source, is used for food preparation and provides at least one of the following functions:

surface cooking;

oven cooking; and

broiling.

s. 58 — Energy-using product

A gas range is prescribed as an energy-using product.

s. 58(2) — Limit

However, for the purposes of sections 4, 5 and 59, a gas range is not considered to be an energy-using product unless it is manufactured on or after February 3, 1995.

s. 59 — Energy efficiency standard

The energy efficiency standard that applies to a gas range is that it must not have a continuously burning pilot light.

s. 60 — Information

For the purpose of subsection 5(1) of the Act, the following information must be collected in accordance with CSA C358-03 and provided to the Minister in respect of a gas range:

the volume of usable oven space, expressed in litres;

information that indicates whether the product is built-in or free-standing; and

the broiler configuration, namely, open or closed.

Dehumidifiers

s. 61 — Definitions

The following definitions apply in this Subdivision.

CSA C749-07 means the CSA standard CAN/CSA-C749-07 entitled Performance of Dehumidifiers. (CSA C749-07)

CSA C749-94 means the CSA standard CAN/CSA-C749-94 entitled Performance of Dehumidifiers. (CSA C749-94)

dehumidifier means a household appliance that is primarily designed to remove moisture from the air and is

self-contained and encased;

electrically operated; and

mechanically refrigerated. (déshumidificateur)

portable dehumidifier means a dehumidifier that is not a whole-home dehumidifier. (déshumidificateur portatif)

10 C.F.R. Appendix X1 means Appendix X1 to Subpart B of Part 430 of Title 10 to the United States Code of Federal Regulations, entitled Uniform Test Method for Measuring the Energy Consumption of Dehumidifiers, as amended from time to time. (appendice X1 10 C.F.R.)

10 C.F.R. §430.32(v)(2) means the table to paragraph 430.32(v)(2) of Subpart C, Part 430 of Title 10 to the United States Code of Federal Regulations, as amended from time to time. (10 C.F.R. §430.32(v)(2))

whole-home dehumidifier means a dehumidifier that is designed to be installed in an air duct. (déshumidificateur à conduit)

s. 62 — Energy-using product

A dehumidifier is prescribed as an energy-using product.

s. 62(2) — Limit

However, for the purposes of sections 4, 5 and 63, a dehumidifier is not considered to be an energy-using product unless

it is manufactured on or after December 31, 1998; and

in the case of a whole-home dehumidifier, it is manufactured on or after June 13, 2019.

s. 63 — Energy efficiency standards

The energy efficiency standards set out in column 3 of the table to this section apply to dehumidifiers described in column 1 that are manufactured during the periods set out in column 4.

s. 63(2) — Testing standard

A dehumidifier complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by the standard set out in column 2 that are applicable to a dehumidifier as defined in section 61. TABLE Column 1 Column 2 Column 3 Column 4 Item Energy-using Product Testing Standard Energy Efficiency Standard Period of Manufacture 1 Dehumidifiers CSA C749-94 CSA C749-94, clause 4.2 On or after December 31, 1998 and before October 1, 2007 2 Dehumidifiers CSA C749-07 CSA C749-07, Table 1 On or after October 1, 2007 and before October 1, 2012 3 Dehumidifiers CSA C749-07 CSA C749-07, Table 1B On or after October 1, 2012 and before June 13, 2019 4 Portable dehumidifiers 10 C.F.R. Appendix X1 Minimum integrated energy factor applicable, based on product’s capacity, as set out in 10 C.F.R. §430.32(v)(2) On or after June 13, 2019 5 Whole-home dehumidifiers 10 C.F.R. Appendix X1 Minimum integrated energy factor applicable, based on product’s case volume, as set out in 10 C.F.R. §430.32(v)(2) On or after June 13, 2019

s. 64 — Information

For the purpose of subsection 5(1) of the Act, the information set out in column 3 of the table to this section must be collected in accordance with the standard set out in column 2 and provided to the Minister in respect of a dehumidifier described in column 1. TABLE Column 1 Column 2 Column 3 Item Energy-using Product Testing Standard Information 1 Dehumidifiers manufactured before October 1, 2007 CSA C749-94 2 Dehumidifiers manufactured on or after October 1, 2007 and before June 13, 2019 CSA C749-07 3 Dehumidifiers manufactured on or after June 13, 2019 10 C.F.R. Appendix X1

Microwave Ovens

s. 65 — Definitions

The following definitions apply in this Subdivision.

CSA C388-15 means the CSA standard CAN/CSA-C388-15 entitled Energy performance and capacity measurement of household microwave ovens. (CSA C388-15)

microwave oven means a household cooking appliance that is designed to cook or heat food in a compartment by means of microwave energy and includes one that has a thermal element that is designed for the surface browning of food. (four à micro-ondes)

10 C.F.R. Appendix I means Appendix I to Subpart B, Part 430 of Title 10 to the United States Code of Federal Regulations, entitled Uniform Test Method for Measuring the Energy Consumption of Microwave Ovens, as amended from time to time. (appendice I 10 C.F.R.)

10 C.F.R. §430.32(j)(3) means paragraph 430.32(j)(3) of Subpart C, Part 430 of Title 10 to the United States Code of Federal Regulations, as amended from time to time. (10 C.F.R. §430.32(j)(3))

s. 66 — Type

For the purposes of these Regulations, a microwave oven is one of the following types:

microwave-only oven;

countertop convection microwave oven;

built-in convection microwave oven; or

over-the-range convection microwave oven.

s. 67 — Energy-using product

A microwave oven is prescribed as an energy-using product.

s. 67(2) — Limit

However, for the purposes of sections 4, 5 and 68, a microwave oven is not considered to be an energy-using product unless it is manufactured on or after March 31, 2019.

s. 68 — Energy efficiency standard

The energy efficiency standard for a microwave oven is the standard set out for that type of microwave oven in 10 C.F.R. §430.32(j)(3).

s. 68(2) — Testing standard

A microwave oven complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by CSA C388-15 or 10 C.F.R. Appendix I that are applicable to a microwave oven as defined in section 65.

s. 69 — Information

For the purpose of subsection 5(1) of the Act, the following information must be provided to the Minister in respect of a microwave oven:

its type;

its volume, expressed in litres (cubic feet); and

its standby power, expressed in watts, as collected in accordance with CSA C388-15 or 10 C.F.R. Appendix I.

Miscellaneous Refrigeration Products

s. 70 — Definitions

The following definitions apply in this Subdivision.

10 C.F.R. Appendix A means Appendix A to Subpart B, Part 430 of Title 10 to the United States Code of Federal Regulations, entitled Uniform Test Method for Measuring the Energy Consumption of Refrigerators, Refrigerator-Freezers, and Miscellaneous Refrigeration Products, as amended from time to time. (appendice A 10 C.F.R.)

10 C.F.R. §430.32(aa)(1) means the table to paragraph 430.32(aa)(1) of Subpart C, Part 430 of Title 10 to the United States Code of Federal Regulations, as amended from time to time. (10 C.F.R. §430.32(aa)(1))

10 C.F.R. §430.32(aa)(2) means the table to paragraph 430.32(aa)(2) of Subpart C, Part 430 of Title 10 to the United States Code of Federal Regulations, as amended from time to time. (10 C.F.R. §430.32(aa)(2))

miscellaneous refrigeration product means a household refrigeration product, which includes a cooler and combination cooler refrigeration product, but does not include a refrigerator, refrigerator-freezer or freezer. (appareil de réfrigération divers)

s. 71 — Type

For the purposes of these Regulations, a miscellaneous refrigeration product is one of the following types:

if it was manufactured on or after January 1, 2008 and before October 28, 2019, a type described in any of the product types (19) or (20) of Table 1 to CSA C300-15; or

if it is manufactured on or after October 28, 2019, a cooler of a product class described in 10 C.F.R. §430.32(aa)(1) or a combination cooler refrigeration product of a product class described in 10 C.F.R. §430.32(aa)(2).

s. 72 — Energy-using product

A miscellaneous refrigeration product is prescribed as an energy-using product.

s. 72(2) — Limits

However, for the purposes of sections 4, 5, 13 to 15 and 73, a miscellaneous refrigeration product is not considered to be an energy-using product unless

it is manufactured on or after January 1, 2008 and before October 28, 2019, and is a type (19) or (20) as described in Table 1 to CSA C300-15; or

it is manufactured on or after October 28, 2019.

s. 73 — Energy efficiency standard

The energy efficiency standards set out in column 3 of the table to this section apply to miscellaneous refrigeration products described in column 1 that are manufactured during the periods set out in column 4.

s. 73(2) — Testing standard

A miscellaneous refrigeration product complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by the standard set out in column 2 that are applicable to a miscellaneous refrigeration product as defined in section 70. TABLE Item Column 1 Column 2 Column 3 Column 4 Energy-using Product Testing Standard Energy Efficiency Standard Period of Manufacture 1 Miscellaneous refrigeration products CSA C300-12 CSA C300-12, Table 1 On or after January 1, 2008 and before September 15, 2014 2 Miscellaneous refrigeration products CSA C300-15 CSA C300-15, Table 1 On or after September 15, 2014 and before October 28, 2019 3 Miscellaneous refrigeration products – coolers 10 C.F.R. Appendix A 10 C.F.R. §430.32(aa)(1) On or after October 28, 2019 4 Miscellaneous refrigeration products – combination cooler refrigeration products 10 C.F.R. Appendix A 10 C.F.R. §430.32(aa)(2) On or after October 28, 2019

s. 74 — Information

For the purpose of subsection 5(1) of the Act, the following information must be provided to the Minister in respect of a miscellaneous refrigeration product:

its type;

its adjusted volume; and

its annual energy consumption expressed in kilowatt-hours.

s. 74(2) — Standard

The information must be collected in accordance with one of the following standards:

CSA C300-12 if the product was manufactured on or after January 1, 2008 and before September 15, 2014;

CSA C300-15 if the product was manufactured on or after September 15, 2014 and before October 28, 2019; or

10 C.F.R. Appendix A if the product is manufactured on or after October 28, 2019.

Ceiling Fans

s. 75 — Definitions

The following definitions apply in this Subdivision.

10 C.F.R. Appendix U means Appendix U to Subpart B, Part 430 of Title 10 to the United States Code of Federal Regulations, entitled Uniform Test Method for Measuring the Energy Consumption of Ceiling Fans, as amended from time to time. (appendice U 10 C.F.R.)

10 C.F.R. §430.32(s)(2)(i) means the table to subparagraph 430.32(s)(2)(i) of Subpart C, Part 430 of Title 10 to the United States Code of Federal Regulations, as amended from time to time. (10 C.F.R. §430.32(s)(2)(i))

ceiling fan means a non-portable device that is suspended from a ceiling for circulating air via the rotation of fan blades. It does not include

a ceiling fan if the plane of rotation of the fan blades is greater than 45 degrees from horizontal;

a centrifugal ceiling fan;

a belt-driven ceiling fan;

an oscillating ceiling fan; and

a ceiling fan with a maximum rotational speed of 90 RPM and a maximum airflow of 52.1 cubic metres/minute (1840 cubic feet/minute). (ventilateur de plafond)

s. 76 — Type

For the purposes of these Regulations, a ceiling fan is one of the following types:

very small diameter;

standard;

hugger;

high-speed small-diameter; or

large-diameter.

s. 77 — Energy-using product

A ceiling fan is prescribed as an energy-using product.

s. 77(2) — Limits

However, for the purposes of sections 4, 5 and 78, a ceiling fan is not considered to be an energy-using product unless it is manufactured on or after January 21, 2020.

s. 78 — Energy efficiency standard

The energy efficiency standard for a ceiling fan is the standard as set out in 10 C.F.R. §430.32(s)(2)(i).

s. 78(2) — Testing standard

A ceiling fan complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by 10 C.F.R. Appendix U that are applicable to a ceiling fan as defined in section 75.

s. 79 — Information

For the purpose of subsection 5(1) of the Act, the following information must be collected in accordance with 10 C.F.R. Appendix U and provided to the Minister in respect of a ceiling fan:

its type;

its blade span;

its air flow at high speed;

its ceiling fan efficiency; and

its standby power consumption expressed in watts.

Air Conditioners, Condensing Units and Chillers

Interpretation

s. 107 — Definitions

The following definitions apply in this Division.

CEER means the combined energy efficiency ratio of the product, expressed in British thermal units per watt hour, that constitutes a single measure of its energy efficiency and that integrates standby mode and off mode energy use with on mode energy use. (CEER)

CSA C656-05 means the CSA standard CAN/CSA-C656-05 entitled Performance Standard for Split-System and Single-Package Central Air Conditioners and Heat Pumps. (CSA C656-05)

CSA C656-14 means the CSA standard CSA-C656-14 entitled Performance Standard for Split-System and Single-Package Central Air Conditioners and Heat Pumps. (CSA C656-14)

CSA C746-06 means the CSA standard CAN/CSA-C746-06 entitled Performance Standard for Rating Large and Single Packaged Vertical Air Conditioners and Heat Pumps. (CSA C746-06)

CSA C746-98 means the CSA standard CAN/CSA-C746-98 entitled Performance Standard for Rating Large Air Conditioners and Heat Pumps. (CSA C746-98)

small-duct and high-velocity, with respect to a single package central air conditioner or a split-system central air conditioner, means one that has an indoor blower and coil combination that

produces at least 300 Pa (1.2 inches of water) external static pressure when operated at an air volume rate of 104 to 165 L/s (220 to 350 cubic feet/minute) per nominal ton of cooling; and

uses room outlets that produce velocities greater than 5 m/s (1,000 feet/minute) and that each have an area less than 39 cm 2 (6 square inches). (à grand débit et à petits conduits)

space-constrained, with respect to a single package central air conditioner or a split system central air conditioner, means one that

has a cooling capacity that is less than or equal to 8.79 kW (30,000 Btu/h); and

has an outdoor or indoor unit

that has an overall displacement that is — or two or more overall exterior dimensions that are — substantially smaller than those of other units of a similar cooling capacity that are usually installed in single-family homes, and

with respect to which an increase in the overall displacement or two or more overall exterior dimensions would result in a considerable increase in the usual cost of installation or in a significant loss in the utility of the product to the consumer. (à espace restreint)

10 C.F.R. Appendix F1 means Appendix F1 to Subpart F, Part 431 of Title 10 to the United States Code of Federal Regulations, entitled Uniform Test Method for the Measurement of Energy Consumption of Air-Cooled, Three-Phase, Small Commercial Package Air Conditioning and Heating Equipment With a Cooling Capacity of Less Than 65,000 Btu/h and Air-Cooled, Three-Phase, Variable Refrigerant Flow Multi-Split Air Conditioners and Heat Pumps With a Cooling Capacity of Less Than 65,000 Btu/h, as amended from time to time. (appendice F1 10 C.F.R.)

10 C.F.R. Appendix M means Appendix M to Subpart B, Part 430 of Title 10 to the United States Code of Federal Regulations, entitled Uniform Test Method for Measuring the Energy Consumption of Central Air Conditioners and Heat Pumps, as amended from time to time. (appendice M 10 C.F.R)

10 C.F.R. Appendix M1 means Appendix M1 to Subpart B, Part 430 of Title 10 to the United States Code of Federal Regulations, entitled Uniform Test Method for Measuring the Energy Consumption of Central Air Conditioners and Heat Pumps, as amended from time to time. (appendice M1 10 C.F.R.)

s. 107.1 — Type

For the purposes of these Regulations, a central air conditioner manufactured on or after January 1, 2023 is one of the following types:

single package, other than space-constrained;

space-constrained single package;

split system, other than space-constrained or small-duct and high-velocity;

small-duct and high-velocity split-system; or

space-constrained split-system.

Room Air Conditioners

s. 108 — Definitions

The following definitions apply in this Subdivision.

CEER[Repealed, SOR/2025-110, s. 8]

CSA C368.1 means the CSA standard CAN/CSA-C368.1-M90 entitled Performance Standard for Room Air Conditioners. (CSA C368.1)

CSA C368.1-14[Repealed, SOR/2025-110, s. 8]

CSA C370[Repealed, SOR/2019-163, s. 15]

CSA C62301[Repealed, SOR/2025-110, s. 8]

off mode[Repealed, SOR/2018-201, s. 18]

on mode[Repealed, SOR/2018-201, s. 18]

portable air conditioner[Repealed, SOR/2019-163, s. 15]

room air conditioner means a single-phase electric air conditioner that has a cooling capacity of 10.55 kW (36,000 Btu/h) or less. It does not include a packaged terminal air conditioner, a portable air conditioner or a single package vertical air conditioner. (climatiseur individuel)

standby mode[Repealed, SOR/2018-201, s. 18]

TSD D2SA001 means the technical standards document D2SA001 published by the Minister and entitled Testing Standard and Energy Efficiency Standards for Room Air Conditioners. (DNT D2SA001)

s. 109 — Type

For the purposes of these Regulations, a room air conditioner is one of the following types:

120 V louvred with reverse cycle;

120 V louvred without reverse cycle;

120 V non-louvred with reverse cycle;

120 V non-louvred without reverse cycle;

120 V casement-only;

120 V casement-slider;

240 V louvred with reverse cycle;

240 V louvred without reverse cycle;

240 V non-louvred with reverse cycle;

240 V non-louvred without reverse cycle;

240 V casement-only; or

240 V casement-slider.

s. 110 — Cooling capacity category

For the purposes of these Regulations, the cooling capacity category of a room air conditioner is the applicable cooling capacity range set out in

Table 2 of CSA C368.1, if the product was manufactured before June 1, 2014;

Table 2 to Part 2 of TSD D2SA001, if the product is manufactured on or after June 1, 2014 and before May 26, 2026; and

Table 3 to Part 2 of TSD D2SA001, if the product is manufactured on or after May 26, 2026.

s. 111 — Energy-using product

A room air conditioner is prescribed as an energy-using product.

s. 111(2) — Limit

However, for the purposes of sections 4, 5, 112, 114 and 115, a room air conditioner is not considered to be an energy-using product unless it is manufactured on or after February 3, 1995.

s. 112 — Energy efficiency standards

The energy efficiency standards set out in column 2 of the table to this section apply to room air conditioners that are manufactured during the periods set out in column 3.

s. 112(2) — Testing standard

A room air conditioner complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by the standard set out in column 1 that are applicable to a room air conditioner as defined in section 108. TABLE Column 1 Column 2 Column 3 Item Testing Standard Energy Efficiency Standard Period of Manufacture 1 CSA C368.1 CSA C368.1, Table 2, second column On or after February 3, 1995 and before June 1, 2014 2 Part 1 of TSD D2SA001 Part 2 of TSD D2SA001 On or after June 1, 2014

s. 113 — Information

For the purpose of subsection 5(1) of the Act, the information set out in column 3 of the table to this section must be collected in accordance with the standard or provision set out in column 2 and provided to the Minister in respect of a room air conditioner described in column 1. TABLE Column 1 Column 2 Column 3 Item Energy-using Product Testing Standard Information 1 Room air conditioners manufactured before June 1, 2014 CSA C368.1, for information set out in paragraphs (b) to (d) 2 Room air conditioners manufactured on or after June 1, 2014

s. 114 — Form of labelling

A room air conditioner must be labelled

if it was manufactured before June 1, 2014, in the form set out in Schedule 2; or

if it is manufactured on or after June 1, 2014, in the form set out in Schedule 3.

s. 115 — Manner of labelling

The label must be displayed on the principal display panel of the product’s package

by printing it on that panel; or

by affixing to the panel an adhesive tag that is printed on paper that meets the requirements of subsection 14(1) and that has an adhesion capacity that is sufficient to prevent the tag from being dislodged from the packaging under normal handling conditions.

Large Air Conditioners

s. 116 — Definitions

The following definitions apply in this Subdivision.

AHRI 340/360 means the AHRI standard ANSI/AHRI 340/360-2007 entitled Performance Rating of Commercial and Industrial Unitary Air-Conditioning and Heat Pump Equipment. (AHRI 340/360)

CSA C746-17 means the CSA standard CAN/CSA-C746-17 entitled Energy performance rating for large and single packaged vertical air conditioners and heat pumps. (CSA C746-17)

IEER means the integrated energy efficiency ratio, expressed in British thermal units per watt hour, that constitutes a single number cooling part-load efficiency metric of a large air conditioner. (IEER)

large air conditioner means a commercial or industrial unitary air conditioner with a cooling capacity of at least 19 kW (65,000 Btu/h) but less than 223 kW (760,000 Btu/h). It does not include a single package vertical air conditioner. (climatiseur de grande puissance)

10 C.F.R. Appendix A means Appendix A to Subpart F, Part 431 of Title 10 to the United States Code of Federal Regulations, entitled Uniform Test Method for the Measurement of Energy Consumption of Air-Cooled Small (≥65,000 Btu/h), Large, and Very Large Commercial Package Air Conditioning and Heating Equipment, as amended from time to time. (appendice A 10 C.F.R.)

s. 117 — Energy-using product

A large air conditioner is prescribed as an energy-using product.

s. 117(2) — Limits

However, for the purposes of sections 4, 5 and 118, a large air conditioner is not considered to be an energy-using product unless

in the case of a large air conditioner with a cooling capacity of less than 70 kW, it is manufactured on or after December 31, 1998; and

in the case of a large air conditioner with a cooling capacity of 70 kW or more, it is manufactured on or after January 1, 2010.

s. 118 — Energy efficiency standards — cooled by air

The energy efficiency standards set out in column 3 of Table 1 to this section apply to large air conditioners that are cooled by air and described in column 1 and that are manufactured during the period set out in column 4.

s. 118(2) — Energy efficiency standards — cooled by water

The energy efficiency standards set out in column 3 of Table 2 to this section apply to large air conditioners that are cooled by water and described in column 1 and that are manufactured during the period set out in column 4.

s. 118(2.1) — Energy efficiency standards — cooled by evaporation

The energy efficiency standards set out in column 3 of Table 3 to this section apply to large air conditioners that are cooled by evaporation and described in column 1 and that are manufactured during the period set out in column 4.

s. 118(3) — Testing standard

A large air conditioner complies with the energy efficiency standard set out in column 3 if it meets that standard when tested in accordance with testing procedures established by the standard set out in column 2 that are applicable to a large air conditioner as defined in section 116. TABLE 1 Column 1 Column 2 Column 3 Column 4 Item Energy-using Product Testing Standard Energy Efficiency Standard Period of Manufacture 1 Large air conditioners that have a cooling capacity of ≥ 19 kW and < 40 kW and either without a heating section or with an electric heating section CSA C746-98 Energy efficiency ratio ≥ 10.3 On or after December 31, 1998 and before January 1, 2010 2 Large air conditioners that have a cooling capacity of ≥ 19 kW and < 40 kW and either without a heating section or with an electric heating section On or after January 1, 2010 and before January 1, 2018 3 Large air conditioners that have a cooling capacity of ≥ 19 kW and < 40 kW and either without a heating section or with an electric heating section CSA C746-17 On or after January 1, 2018 and before January 1, 2026 4 Large air conditioners that have a cooling capacity of ≥ 19 kW and < 40 kW and either without a heating section or with an electric heating section CSA C746-17 or 10 C.F.R. Appendix A On or after January 1, 2026 5 Large air conditioners that have a cooling capacity of ≥ 40 kW and < 70 kW and either without a heating section or with an electric heating section CSA C746-98 Energy efficiency ratio ≥ 9.7 On or after December 31, 1998 and before January 1, 2010 6 Large air conditioners that have a cooling capacity of ≥ 40 kW and < 70 kW and either without a heating section or with an electric heating section On or after January 1, 2010 and before January 1, 2018 7 Large air conditioners that have a cooling capacity of ≥ 40 kW and < 70 kW and either without a heating section or with an electric heating section CSA C746-17 On or after January 1, 2018 and before January 1, 2026 8 Large air conditioners that have a cooling capacity of ≥ 40 kW and < 70 kW and either without a heating section or with an electric heating section CSA C746-17 or 10 C.F.R. Appendix A On or after January 1, 2026 9 Large air conditioners that have a cooling capacity of ≥ 70 kW and < 223 kW and either without a heating section or with an electric heating section On or after January 1, 2010 and before January 1, 2018 10 Large air conditioners that have a cooling capacity of ≥ 70 kW and < 223 kW and either without a heating section or with an electric heating section CSA C746-17 On or after January 1, 2018 and before January 1, 2026 11 Large air conditioners that have a cooling capacity of ≥ 70 kW and < 223 kW and either without a heating section or with an electric heating section CSA C746-17 or 10 C.F.R. Appendix A On or after January 1, 2026 12 Large air conditioners that have a cooling capacity of ≥ 19 kW and < 40 kW and a heating section other than an electric heating section CSA C746-98 Energy efficiency ratio ≥ 10.1 On or after December 31, 1998 and before January 1, 2010 13 Large air conditioners that have a cooling capacity of ≥ 19 kW and < 40 kW and a heating section other than an electric heating section On or after January 1, 2010 and before January 1, 2018 14 Large air conditioners that have a cooling capacity of ≥ 19 kW and < 40 kW and a heating section other than an electric heating section CSA C746-17 On or after January 1, 2018 and before January 1, 2026 15 Large air conditioners that have a cooling capacity of ≥ 19 kW and < 40 kW and a heating section other than an electric heating section CSA C746-17 or 10 C.F.R. Appendix A On or after January 1, 2026 16 Large air conditioners that have a cooling capacity of ≥ 40 kW and < 70 kW and a heating section other than an electric heating section CSA C746-98 Energy efficiency ratio ≥ 9.5 On or after December 31, 1998 and before January 1, 2010 17 Large air conditioners that have a cooling capacity of ≥ 40 kW and < 70 kW and a heating section other than an electric heating section On or after January 1, 2010 and before January 1, 2018 18 Large air conditioners that have a cooling capacity of ≥ 40 kW and < 70 kW and a heating section other than an electric heating section CSA C746-17 On or after January 1, 2018 and before January 1, 2026 19 Large air conditioners that have a cooling capacity of ≥ 40 kW and < 70 kW and a heating section other than an electric heating section CSA C746-17 or 10 C.F.R. Appendix A On or after January 1, 2026 20 Large air conditioners that have a cooling capacity of ≥ 70 kW and < 223 kW and a heating section other than an electric heating section On or after January 1, 2010 and before January 1, 2018 21 Large air conditioners that have a cooling capacity of ≥ 70 kW and < 223 kW and a heating section other than an electric heating section CSA C746-17 On or after January 1, 2018 and before January 1, 2026 22 Large air conditioners that have a cooling capacity of ≥ 70 kW and < 223 kW and a heating section other than an electric heating section CSA C746-17 or 10 C.F.R. Appendix A On or after January 1, 2026 TABLE 2 Column 1 Column 2 Column 3 Column 4 Item Energy-using Product Testing Standard Energy Efficiency Standard Period of Manufacture 1 Large air conditioners that have a cooling capacity of ≥ 19 kW and < 40 kW and either without a heating section or with an electric heating section CSA C746-98 Energy efficiency ratio ≥ 11.5 On or after December 31, 1998 and before January 1, 2010 2 Large air conditioners that have a cooling capacity of ≥ 19 kW and < 40 kW and either without a heating section or with an electric heating section On or after January 1, 2010 and before January 1, 2018 3 Large air conditioners that have a cooling capacity of ≥ 19 kW and < 40 kW and either without a heating section or with an electric heating section CSA C746-17 On or after January 1, 2018 4 Large air conditioners that have a cooling capacity of ≥ 40 kW and < 70 kW and either without a heating section or with an electric heating section CSA C746-98 Energy efficiency ratio ≥ 11.0 On or after December 31, 1998 and before January 1, 2010 5 Large air conditioners that have a cooling capacity of ≥ 40 kW and < 70 kW and either without a heating section or with an electric heating section On or after January 1, 2010 and before January 1, 2018 6 Large air conditioners that have a cooling capacity of ≥ 40 kW and < 70 kW and either without a heating section or with an electric heating section CSA C746-17 On or after January 1, 2018 7 Large air conditioners that have a cooling capacity of ≥ 19 kW and < 40 kW and a heating section other than an electric heating section CSA C746-98 Energy efficiency ratio ≥ 11.3 On or after December 31, 1998 and before January 1, 2010 8 Large air conditioners that have a cooling capacity of ≥ 19 kW and < 40 kW and a heating section other than an electric heating section On or after January 1, 2010 and before January 1, 2018 9 Large air conditioners that have a cooling capacity of ≥ 19 kW and < 40 kW and a heating section other than an electric heating section CSA C746-17 On or after January 1, 2018 10 Large air conditioners that have a cooling capacity of ≥ 40 kW and < 70 kW and a heating section other than an electric heating section CSA C746-98 Energy efficiency ratio ≥ 10.8 On or after December 31, 1998 and before January 1, 2010 11 Large air conditioners that have a cooling capacity of ≥ 40 kW and < 70 kW and a heating section other than an electric heating section On or after January 1, 2010 and before January 1, 2018 12 Large air conditioners that have a cooling capacity of ≥ 40 kW and < 70 kW and a heating section other than an electric heating section CSA C746-17 On or after January 1, 2018 13 Large air conditioners that have a cooling capacity of ≥ 70 kW and < 223 kW and either without a heating section or with an electric heating section On or after January 1, 2010 and before January 1, 2018 14 Large air conditioners that have a cooling capacity of ≥ 70 kW and < 223 kW and either without a heating section or with an electric heating section CSA C746-17 On or after January 1, 2018 15 Large air conditioners that have a cooling capacity of ≥ 70 kW and < 223 kW and a heating section other than an electric heating section On or after January 1, 2010 and before January 1, 2018 16 Large air conditioners that have a cooling capacity of ≥ 70 kW and < 223 kW and a heating section other than an electric heating section CSA C746-17 On or after January 1, 2018 TABLE 3 Column 1 Column 2 Column 3 Column 4 Item Energy-using Product Testing Standard Energy Efficiency Standard Period of Manufacture 1 Large air conditioners that have a cooling capacity of ≥ 19 kW and < 40 kW and either without a heating section or with an electric heating section CSA C746-98 Energy efficiency ratio ≥ 11.5 On or after December 31, 1998 and before January 1, 2010 2 Large air conditioners that have a cooling capacity of ≥ 19 kW and < 40 kW and either without a heating section or with an electric heating section On or after January 1, 2010 and before January 1, 2018 3 Large air conditioners that have a cooling capacity of ≥ 19 kW and < 40 kW and either without a heating section or with an electric heating section CSA C746-17 On or after January 1, 2018 4 Large air conditioners that have a cooling capacity of ≥ 40 kW and < 70 kW and either without a heating section or with an electric heating section CSA C746-98 Energy efficiency ratio ≥ 11.0 On or after December 31, 1998 and before January 1, 2010 5 Large air conditioners that have a cooling capacity of ≥ 40 kW and < 70 kW and either without a heating section or with an electric heating section On or after January 1, 2010 and before January 1, 2018 6 Large air conditioners that have a cooling capacity of ≥ 40 kW and < 70 kW and either without a heating section or with an electric heating section CSA C746-17 On or after January 1, 2018 7 Large air conditioners that have a cooling capacity of ≥ 19 kW and < 40 kW and a heating section other than an electric heating section CSA C746-98 Energy efficiency ratio ≥ 11.3 On or after December 31, 1998 and before January 1, 2010 8 Large air conditioners that have a cooling capacity of ≥ 19 kW and < 40 kW and a heating section other than an electric heating section On or after January 1, 2010 and before January 1, 2018 9 Large air conditioners that have a cooling capacity of ≥ 19 kW and < 40 kW and a heating section other than an electric heating section CSA C746-17 On or after January 1, 2018 10 Large air conditioners that have a cooling capacity of ≥ 40 kW and < 70 kW and a heating section other than an electric heating section CSA C746-98 Energy efficiency ratio ≥ 10.8 On or after December 31, 1998 and before January 1, 2010 11 Large air conditioners that have a cooling capacity of ≥ 40 kW and < 70 kW and a heating section other than an electric heating section On or after January 1, 2010 and before January 1, 2018 12 Large air conditioners that have a cooling capacity of ≥ 40 kW and < 70 kW and a heating section other than an electric heating section CSA C746-17 On or after January 1, 2018 13 Large air conditioners that have a cooling capacity of ≥ 70 kW and < 223 kW and either without a heating section or with an electric heating section On or after January 1, 2010 and before January 1, 2018 14 Large air conditioners that have a cooling capacity of ≥ 70 kW and < 223 kW and either without a heating section or with an electric heating section CSA C746-17 On or after January 1, 2018 15 Large air conditioners that have a cooling capacity of ≥ 70 kW and < 223 kW and a heating section other than an electric heating section On or after January 1, 2010 and before January 1, 2018 16 Large air conditioners that have a cooling capacity of ≥ 70 kW and < 223 kW and a heating section other than an electric heating section CSA C746-17 On or after January 1, 2018

s. 119 — Information

For the purpose of subsection 5(1) of the Act, the information set out in column 3 of the table to this section must be collected in accordance with the standard set out in column 2 and provided to the Minister in respect of a large air conditioner described in column 1. TABLE Column 1 Column 2 Column 3 Item Energy-using Product Testing Standard Information 1 Large air conditioners manufactured on or after December 31, 1998 and before January 1, 2010 CSA C746-98 2 Large air conditioners manufactured on or after January 1, 2010 and before January 1, 2018 3 Large air conditioners manufactured on or after January 1, 2018 and before January 1, 2026 CSA C746-17 4 Large air conditioners manufactured on or after January 1, 2026 CSA C746-17 or 10 C.F.R. Appendix A

Packaged Terminal Air Conditioners

s. 120 — Definitions

The following definitions apply in this Subdivision.

CSA C744-04 means the joint CSA and AHRI standard ANSI/AHRI 310/380-2004/CAN/CSA-C744-04 entitled Standard for Packaged Terminal Air Conditioners and Heat Pumps. (CSA C744-04)

CSA C744-14 means the joint CSA and AHRI standard ANSI/AHRI 310/380-2014/CAN/CSA-C744-14 entitled Standard for Packaged Terminal Air Conditioners and Heat Pumps. (CSA C744-14)

CSA C744-17 means the joint CSA and AHRI standard ANSI/AHRI 310/380-2017/CAN/CSA-C744-17 entitled Packaged terminal air-conditioners and heat pumps. (CSA C744-17 )

packaged terminal air conditioner means a factory-built packaged terminal air conditioner that

consists of a wall sleeve and a separate unencased cooling component and is intended to cool a single room or zone; or

consists of a wall sleeve and a separate unencased combination of heating and cooling components and is intended to heat and cool a single room or zone. (climatiseur terminal autonome)

s. 121 — Energy-using product

A packaged terminal air conditioner is prescribed as an energy-using product.

s. 121(2) — Limit

However, for the purposes of sections 4, 5 and 122, a packaged terminal air conditioner is not considered to be an energy-using product unless it is manufactured on or after December 31, 1998.

s. 122 — Energy efficiency standards

The energy efficiency standards set out in column 2 of the table to this section apply to packaged terminal air conditioners that are manufactured during the periods set out in column 3.

s. 122(2) — Testing standard

A packaged terminal air conditioner complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by the standard set out in column 1 that are applicable to a packaged terminal air conditioner as defined in section 120. TABLE Column 1 Column 2 Column 3 Item Testing Standard Energy Efficiency Standard Period of Manufacture 1 CSA C744-04 CSA C744-04, Table 2 On or after December 31, 1998 and before September 30, 2012 2 CSA C744-14 CSA C744-14, Table 2 On or after September 30, 2012 and before January 1, 2017 3 CSA C744-17 CSA C744-17, Table 2 On or after January 1, 2017

s. 123 — Information

For the purpose of subsection 5(1) of the Act, the following information must be provided to the Minister in respect of a packaged terminal air conditioner:

its cooling capacity, expressed in kilowatts (British thermal units per hour);

its energy efficiency ratio; and

if applicable, identification of the product as a replacement unit.

s. 123(2) — Standard

The information must be collected in accordance with

CSA C744-04, if the product was manufactured on or after December 31, 1998 and before September 30, 2012;

CSA C744-14, if the product was manufactured on or after September 30, 2012 and before January 1, 2017; or

CSA C744-17, if the product is manufactured on or after January 1, 2017.

Single Package Central Air Conditioners

s. 124 — Definitions

The following definitions apply in this Subdivision.

off mode power consumption means the power consumption when the unit is connected to mains power but is not providing cooling or heating. (consommation d’énergie en mode arrêt)

single package central air conditioner means a single-phase or three-phase central air conditioner that is a single package unit and that has a cooling capacity of less than 19 kW (65,000 Btu/h). It does not include a single package vertical air conditioner. (climatiseur central monobloc)

through-the-wall means, in respect of a single package central air conditioner, one that has a cooling capacity less than or equal to 8.79 kW (30,000 Btu/h), is designed to be installed through an exterior wall and is manufactured prior to January 1, 2023. (mural)

s. 125 — Energy-using product

A single package central air conditioner is prescribed as an energy-using product.

s. 125(2) — Limit

However, for the purposes of sections 4, 5 and 126, a single package central air conditioner is not considered to be an energy-using product unless it is manufactured on or after February 3, 1995.

s. 126 — Energy efficiency standards — single-phase

The energy efficiency standards set out in column 3 of Table 1 to this section apply to single-phase single package central air conditioners described in column 1 that are manufactured during the periods set out in column 4.

s. 126(1.1) — Energy efficiency standards — three-phase

The energy efficiency standards set out in column 3 of Table 2 to this section apply to three-phase single package central air conditioners described in column 1 that are manufactured during the periods set out in column 4.

s. 126(2) — Testing standard

A single package central air conditioner complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by the standard set out in column 2 that are applicable to a single package central air conditioner as defined in section 124. TABLE 1 Column 1 Column 2 Column 3 Column 4 Item Energy-using Product Testing Standard Energy Efficiency Standard Period of Manufacture 1 Single package central air conditioners, other than those that are through-the-wall or small-duct and high-velocity On or after February 3, 1995 and before January 1, 2023 2 Single package central air conditioners that are through-the-wall On or after February 3, 1995 and before January 1, 2023 3 Single package central air conditioners that are small-duct and high-velocity On or after February 3, 1995 and before January 1, 2023 4 Single package central air conditioners, other than those that are space-constrained 10 C.F.R. Appendix M1 On or after January 1, 2023 5 Single package central air conditioners that are space-constrained 10 C.F.R. Appendix M1 On or after January 1, 2023 TABLE 2 Column 1 Column 2 Column 3 Column 4 Item Energy-using Product Testing Standard Energy Efficiency Standard Period of Manufacture 1 Single package central air conditioners, other than those that are through-the-wall, or small-duct and high-velocity CSA C656-14 Seasonal energy efficiency ratio ≥ 14.0 On or after February 3, 1995 and before January 1, 2023 2 Single package central air conditioners, other than those that are space-constrained CSA C656-14 Seasonal energy efficiency ratio ≥ 14.0 On or after January 1, 2023 and before January 1, 2026 3 Single package central air conditioners, other than those that are space-constrained 10 C.F.R. Appendix F1 Seasonal energy efficiency ratio 2 ≥ 13.4 On or after January 1, 2026 4 Single package central air conditioners that are through-the-wall CSA C656-05 Seasonal energy efficiency ratio ≥ 12.0 On or after February 3, 1995 and before January 1, 2023 5 Single package central air conditioners that are space-constrained CSA C656-14 Seasonal energy efficiency ratio ≥ 12.0 On or after January 1, 2023 and before January 1, 2026 6 Single package central air conditioners that are space-constrained 10 C.F.R. Appendix F1 Seasonal energy efficiency ratio 2 ≥ 13.9 On or after January 1, 2026 7 Single package central air conditioners that are small-duct and high-velocity CSA C656-14 Seasonal energy efficiency ratio ≥ 12.0 On or after January 1, 2017 and before January 1, 2023

s. 127 — Information

For the purpose of subsection 5(1) of the Act, the information set out in column 3 of the table to this section must be collected and provided to the Minister in respect of a single package central air conditioner described in column 1 and, if applicable, the information must be collected in accordance with the standard set out in column 2. TABLE Column 1 Column 2 Column 3 Item Energy-using Product Testing Standard Information 1 Single package central air conditioners that are single-phase, other than those that are through-the-wall, manufactured on or after February 3, 1995 and before January 1, 2023 2 Single package central air conditioners that are three-phase, other than those that are through-the-wall, manufactured on or after February 3, 1995 and before January 1, 2023 CSA C656-14 for information set out in paragraphs (a) to (c) 3 Single package central air conditioners that are single-phase, through-the-wall and manufactured on or after February 3, 1995 and before January 1, 2023 4 Single package central air conditioners that are three-phase, through-the-wall and manufactured on or after February 3, 1995 and before January 1, 2023 CSA C656-05 for information set out in paragraphs (a) to (c) 5 Single package central air conditioners that are three-phase and manufactured on or after January 1, 2023 and before January 1, 2026 CSA C656-14 for information set out in paragraphs (a) to (c) 5.1 Single package central air conditioners that are three-phase and manufactured on or after January 1, 2026 10 C.F.R. Appendix F1 for information set out in paragraphs (b) and (c) 6 Single package central air conditioners that are single-phase and manufactured on or after January 1, 2023 10 C.F.R. Appendix M1 for information set out in paragraphs (b) to (d)

s. 127.1 — Early compliance

A single package central air conditioner that is manufactured on or after January 1, 2025 and before January 1, 2026 is deemed to satisfy the requirements of sections 126 and 127 if it satisfies the requirements of those sections that would have applied to the single package central air conditioner if it had been manufactured on or after January 1, 2026.

Single Package Vertical Air Conditioners

s. 128 — Definition of single package vertical air conditioner

In this Subdivision, single package vertical air conditioner means a single package commercial air conditioner, with or without heating capability, that has its major components arranged vertically, is air-cooled and encased and is intended for mounting through, or on either side of, an exterior wall. It does not include a single package commercial air conditioner that has reverse cycle refrigeration.

s. 129 — Energy-using product

A single package vertical air conditioner is prescribed as an energy-using product.

s. 129(2) — Limit

However, for the purposes of sections 4, 5 and 130, a single package vertical air conditioner is not considered to be an energy-using product unless it is manufactured on or after January 1, 2011 and has a cooling capacity of less than 70 kW (240,000 Btu/h).

s. 130 — Energy efficiency standards

The energy efficiency standards set out in column 2 of the table to this section apply to single package vertical air conditioners described in column 1 that are manufactured during the periods set out in column 3.

s. 130(2) — Testing standard

A single package vertical air conditioner complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by CSA C746-17 that are applicable to a single package vertical air conditioner as defined in section 128. TABLE Item Column 1 Column 2 Column 3 Energy-using Product Energy Efficiency Standard Period of Manufacture 1 Single package vertical air conditioners that have a cooling capacity of < 19 kW (65,000 Btu/h) Energy efficiency ratio ≥ 9.0 On or after January 1, 2011 and before September 23, 2019 2 Single package vertical air conditioners that have a cooling capacity of < 19 kW (65,000 Btu/h) Energy efficiency ratio ≥ 11.0 On or after September 23, 2019 3 Single package vertical air conditioners that have a cooling capacity of ≥ 19 kW (65,000 Btu/h) and < 39.5 kW (135,000 Btu/h) Energy efficiency ratio ≥ 8.9 On or after January 1, 2011 and before October 9, 2015 4 Single package vertical air conditioners that have a cooling capacity of ≥ 19 kW (65,000 Btu/h) and < 39.5 kW (135,000 Btu/h) Energy efficiency ratio ≥ 10.0 On or after October 9, 2015 5 Single package vertical air conditioners that have a cooling capacity of ≥ 39.5 kW (135,000 Btu/h) and < 70 kW (240,000 Btu/h) Energy efficiency ratio ≥ 8.6 On or after January 1, 2011 and before October 9, 2016 6 Single package vertical air conditioners that have a cooling capacity of ≥ 39.5 kW (135,000 Btu/h) and < 70 kW (240,000 Btu/h) Energy efficiency ratio ≥ 10.0 On or after October 9, 2016

s. 131 — Information

For the purpose of subsection 5(1) of the Act, the following information must be collected in accordance with CSA C746-17 and provided to the Minister in respect of a single package vertical air conditioner:

its classification as set out in column II of Table 1 to CSA C746-17;

its cooling capacity, expressed in kilowatts (British thermal units per hour); and

its energy efficiency ratio.

Split System Central Air Conditioners

s. 132 — Definitions

The following definitions apply in this Subdivision.

off mode power consumption means the power consumption when the unit is connected to mains power but is not providing cooling or heating. (consommation d’énergie en mode arrêt)

split system central air conditioner means a single-phase or three-phase central air conditioner that is a split system and that has a cooling capacity of less than 19 kW (65,000 Btu/h). (climatiseur central bibloc)

split-system central air conditioner[Repealed, SOR/2022-265, s. 9]

s. 133 — Energy-using product

A split system central air conditioner is prescribed as an energy-using product.

s. 133(2) — Limit

However, for the purposes of sections 4, 5 and 134, a split system central air conditioner is not considered to be an energy-using product unless it is manufactured on or after February 3, 1995.

s. 134 — Energy efficiency standards — single-phase

The energy efficiency standards set out in column 3 of Table 1 to this section apply to single-phase split system central air conditioners described in column 1 that are manufactured during the periods set out in column 4.

s. 134(1.1) — Energy efficiency standards — three-phase

The energy efficiency standards set out in column 3 of Table 2 to this section apply to three-phase split system central air conditioners described in column 1 that are manufactured during the periods set out in column 4.

s. 134(2) — Testing standard

A split system central air conditioner complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by the standard set out in column 2 that are applicable to a split system central air conditioner as defined in section 132. TABLE 1 Column 1 Column 2 Column 3 Column 4 Item Energy-using Product Testing Standard Energy Efficiency Standard Period of Manufacture 1 Split system central air conditioners, other than those that are small-duct and high-velocity On or after February 3, 1995 and before January 1, 2023 2 Split system central air conditioners that are small-duct and high-velocity On or after February 3, 1995 and before January 1, 2023 3 Split system central air conditioners, other than those that are space-constrained or small-duct and high-velocity 10 C.F.R. Appendix M1 On or after January 1, 2023 4 Split system central air conditioners that are small-duct and high-velocity 10 C.F.R. Appendix M1 On or after January 1, 2023 5 Split system central air conditioners that are space-constrained 10 C.F.R. Appendix M1 On or after January 1, 2023 TABLE 2 Column 1 Column 2 Column 3 Column 4 Item Energy-using Product Testing Standard Energy Efficiency Standard Period of Manufacture 1 Split system central air conditioners, other than those that are small-duct and high-velocity CSA C656-14 Seasonal energy efficiency ratio ≥ 13.0 On or after February 3, 1995 and before January 1, 2026 2 Split system central air conditioners, other than those that are space-constrained or small-duct and high-velocity 10 C.F.R. Appendix F1 Seasonal energy efficiency ratio 2 ≥ 13.4 On or after January 1, 2026 3 Split system central air conditioners that are small-duct and high-velocity CSA C656-14 Seasonal energy efficiency ratio ≥ 12.0 On or after February 3, 1995 and before January 1, 2026 4 Split system central air conditioners that are small-duct and high-velocity 10 C.F.R. Appendix F1 Seasonal energy efficiency ratio 2 ≥ 13.0 On or after January 1, 2026 5 Split system central air conditioners that are space-constrained 10 C.F.R. Appendix F1 Seasonal energy efficiency ratio 2 ≥ 12.7 On or after January 1, 2026

s. 135 — Information

For the purpose of subsection 5(1) of the Act, the information set out in column 3 of the table to this section must be collected and provided to the Minister in respect of a split system central air conditioner described in column 1 and, if applicable, the information must be collected in accordance with the standard set out in column 2. TABLE Column 1 Column 2 Column 3 Item Energy-using Product Testing Standard Information 1 Split system central air conditioners that are single-phase and manufactured on or after February 3, 1995 and before January 1, 2023 2 Split system central air conditioners that are three-phase and manufactured on or after February 3, 1995 and before January 1, 2026 CSA C656-14 for information set out in paragraphs (a) to (c) 2.1 Split system central air conditioners that are three-phase and manufactured on or after January 1, 2026 10 C.F.R. Appendix F1 for information set out in paragraphs (b) and (c) 3 Split system central air conditioners that are single-phase and manufactured on or after January 1, 2023 10 C.F.R. Appendix M1 for information set out in paragraphs (b) to (d)

s. 135.1 — Early compliance

A split system central air conditioner that is manufactured on or after January 1, 2025 and before January 1, 2026 is deemed to satisfy the requirements of sections 134 and 135 if it satisfies the requirements of those sections that would have applied to the split system central air conditioner if it had been manufactured on or after January 1, 2026.

Large Condensing Units

s. 136 — Definition of large condensing unit

In this Subdivision, large condensing unit means a commercial or industrial condensing unit that is intended for air conditioning applications and that has a cooling capacity of at least 40 kW (135,000 Btu/h) but not more than 70 kW (240,000 Btu/h).

s. 137 — Energy-using product

A large condensing unit is prescribed as an energy-using product.

s. 137(2) — Limit

However, for the purposes of sections 4, 5 and 138, a large condensing unit is not considered to be an energy-using product unless it is manufactured on or after December 31, 1998.

s. 138 — Energy efficiency standards

The energy efficiency standards set out in column 2 of the table to this section apply to large condensing units described in column 1.

s. 138(2) — Testing standard

A large condensing unit complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by CSA C746-98 that are applicable to a large condensing unit as defined in section 136. TABLE Column 1 Column 2 Item Energy-using Product Energy Efficiency Standard 1 Large condensing units that are cooled by air Energy efficiency ratio ≥ 10.1 2 Large condensing units that are cooled by water or evaporation Energy efficiency ratio ≥ 13.1

s. 139 — Information

For the purpose of subsection 5(1) of the Act, the following information must be collected in accordance with CSA C746-98 and provided to the Minister in respect of a large condensing unit:

its classification as set out in Column II of Table 1 of CSA C746-98;

its cooling capacity, expressed in kilowatts (British thermal units per hour); and

its energy efficiency ratio.

Chillers

s. 140 — Definitions

The following definitions apply in this Subdivision.

ASHRAE 90.1-16 means ANSI/ASHRAE/IES Standard 90.1-2016, entitled Energy Standard for Buildings Except Low-Rise Residential Buildings. (ASHRAE 90.1-16)

chiller means a machine, with or without an integral refrigerant condenser, that is designed to use a refrigerant cycle to remove heat from a liquid and to reject the heat to a cooling medium. (refroidisseur)

CSA C743-02 means the CSA standard CAN/CSA-C743-02 entitled Performance Standard for Rating Packaged Water Chillers. (CSA C743-02)

CSA C743-09 means the CSA standard CAN/CSA-C743-09 entitled Performance Standard for Rating Packaged Water Chillers. (CSA C743-09)

s. 141 — Energy-using product

A chiller is prescribed as an energy-using product.

s. 141(2) — Limit

However, for the purposes of sections 4, 5 and 142, a chiller is not considered to be an energy-using product unless it has an integral refrigerant condenser and is manufactured on or after October 28, 2004.

s. 142 — Energy efficiency standards

The energy efficiency standards set out in column 2 of the table to this section apply to chillers that are manufactured during the periods set out in column 3.

s. 142(2) — Testing standard

A chiller complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by the standard set out in column 1 that are applicable to a chiller as defined in section 140. TABLE Column 1 Column 2 Column 3 Item Testing Standard Energy Efficiency Standard Period of Manufacture 1 CSA C743-02 CSA C743-02, Tables 9 to 15 On or after October 28, 2004 and before January 1, 2017 2 CSA C743-09 Product’s coefficient of performance and integrated part-load value must meet those applicable to the product in CSA C743-09, Path A or Path B, Table 10 On or after January 1, 2017 and before December 31, 2019 3 ASHRAE 90.1-16, table 6.8.1-3, column 6 Product’s coefficient of performance and integrated part-load value must meet those applicable to the product in ASHRAE 90.1-16, Path A or Path B, Table 6.8.1-3 On or after December 31, 2019

s. 143 — Information

For the purpose of subsection 5(1) of the Act, the information set out in column 3 of the table to this section must be collected in accordance with the standard set out in column 2 and provided to the Minister in respect of a chiller described in column 1. TABLE Item Column 1 Column 2 Column 3 Energy-using Product Testing Standard Information 1 Chillers manufactured on or after October 28, 2004 and before January 1, 2017 CSA C743-02 2 Chillers manufactured on or after January 1, 2017 and before December 31, 2019 CSA C743-09 3 Chillers manufactured on or after December 31, 2019 ASHRAE 90.1-16, Table 6.8.1-3, column 6

Portable Air Conditioners

s. 144 — Definitions

The following definitions apply in this Subdivision.

10 C.F.R. Appendix CC means Appendix CC to Subpart B, Part 430 of Title 10 to the United States Code of Federal Regulations, entitled Uniform Test Method for Measuring the Energy Consumption of Portable Air Conditioners, as amended from time to time. (appendice CC 10 C.F.R.)

dual-duct portable air conditioner means a portable air conditioner that draws some or all of the condenser inlet air from outside the conditioned space through a duct attached to an adjustable window bracket and discharges the condenser outlet air outside the conditioned space by means of a separate duct attached to an adjustable window bracket. (climatiseur portative à deux conduits)

portable air conditioner means a single package air conditioner, other than a packaged terminal air conditioner, room air conditioner or dehumidifier, with or without mounted wheels, that is portable and that

is designed to deliver cooled and conditioned air to an enclosed space;

is powered by single-phase electric current; and

has a SACC of less than 19 kW (65,000 Btu/h). (climatiseur portatif)

SACC means the seasonally adjusted cooling capacity of the product, expressed in kilowatts (British thermal units per hour), that constitutes the amount of cooling provided to the conditioned space. (SACC)

single-duct portable air conditioner means a portable air conditioner that draws all of the condenser inlet air from the conditioned space without the means of a duct and discharges the condenser outlet air outside the conditioned space through a single duct attached to an adjustable window bracket. (climatiseur portatif à un conduit unique)

s. 145 — Energy-using product

A portable air conditioner is prescribed as an energy-using product.

s. 145(2) — Limit

However, a portable air conditioner is not considered to be an energy-using product

for the purposes of sections 4 and 5, unless it is manufactured on or after July 1, 2020; and

for the purposes of sections 145.1, 147 and 148, unless it is manufactured on or after January 10, 2025.

s. 145.1 — Energy efficiency standard

The energy efficiency standard applicable to a portable air conditioner is that it must have a CEER equal to or greater than the result determined by the formula 1.04 A ÷ (3.7117 A 0.6384) where A is its SACC, expressed in Btu/h.

s. 145.1(2) — Testing standard

A portable air conditioner complies with the energy efficiency standard if it meets that standard when tested in accordance with the applicable testing procedures established by 10 C.F.R. Appendix CC.

s. 146 — Information

For the purpose of subsection 5(1) of the Act, the following information must be collected in accordance with 10 C.F.R. Appendix CC and provided to the Minister in respect of a portable air conditioner:

its SACC;

its CEER; and

whether it is a single-duct portable air conditioner or a dual-duct portable air conditioner.

s. 146(2) — Additional information

For a product with multiple duct configuration options, the information required by paragraphs 1(a) and (b) must be provided for both applicable duct configurations.

s. 147 — Form of labelling

A portable air conditioner manufactured on or after January 10, 2025 must be labelled in the form set out in Schedule 4.

s. 148 — Manner of labelling

The label must be displayed on the principal display panel of the product’s package, either

by printing it on that panel; or

by affixing to the panel an adhesive tag that is printed on paper that meets the requirements of subsection 14(1) and that has an adhesion capacity that is sufficient to prevent the tag from being dislodged from the packaging under normal handling conditions.

Heat Pumps

Interpretation

s. 186 — Definitions

The following definitions apply in this Division.

CSA C656-05 means the CSA standard CAN/CSA-C656-05 entitled Performance Standard for Split-System and Single-Package Central Air Conditioners and Heat Pumps. (CSA C656-05)

CSA C656-14 means the CSA standard CAN/CSA-C656-14 entitled Performance Standard for Split-System and Single-Package Central Air Conditioners and Heat Pumps. (CSA C656-14)

CSA C746-06 means the CSA standard CAN/CSA-C746-06 entitled Performance Standard for Rating Large and Single Packaged Vertical Air Conditioners and Heat Pumps. (CSA C746-06)

CSA C13256-1 means the CSA standard CAN/CSA-C13256-1-01 entitled Water-Source Heat Pumps — Testing and Rating for Performance — Part 1: Water-to-Air and Brine-to-Air Heat Pumps. (CSA C13256-1)

small-duct and high-velocity means, with respect to a split system central heat pump or a single package central heat pump, one that has an indoor blower and coil combination that

produces at least 300 Pa (1.2 inches of water) external static pressure when operated at an air volume rate of 104 to 165 L/s (220 to 350 cubic feet/minute) per nominal ton of cooling; and

uses room outlets that produce velocities greater than 5 m/s (1,000 feet/minute) and that each have an area less than 39 cm 2 (6 square inches). (à grand débit et à petits conduits)

space-constrained, with respect to a single package central heat pump or a split system central heat pump, means one that

has a cooling capacity that is less than or equal to 8.79 kW (30,000 Btu/h); and

has an outdoor or indoor unit

that has an overall displacement that is — or two or more overall exterior dimensions that are — substantially smaller than those of other units of a similar cooling capacity that are usually installed in single-family homes, and

with respect to which an increase in the overall displacement or two or more overall exterior dimensions would result in a considerable increase in the usual cost of installation or in a significant loss in the utility of the product to the consumer. (à espace restreint)

10 C.F.R. Appendix F1 means Appendix F1 to Subpart F, Part 431 of Title 10 to the United States Code of Federal Regulations, entitled Uniform Test Method for the Measurement of Energy Consumption of Air-Cooled, Three-Phase, Small Commercial Package Air Conditioning and Heating Equipment With a Cooling Capacity of Less Than 65,000 Btu/h and Air-Cooled, Three-Phase, Variable Refrigerant Flow Multi-Split Air Conditioners and Heat Pumps With a Cooling Capacity of Less Than 65,000 Btu/h, as amended from time to time. (appendice F1 10 C.F.R.)

10 C.F.R. Appendix M means Appendix M to Subpart B, Part 430 of Title 10 to the United States Code of Federal Regulations, entitled Uniform Test Method for Measuring the Energy Consumption of Central Air Conditioners and Heat Pumps, as amended from time to time. (appendice M 10 C.F.R.)

10 C.F.R. Appendix M1 means Appendix M1 to Subpart B, Part 430 of Title 10 to the United States Code of Federal Regulations, entitled Uniform Test Method for Measuring the Energy Consumption of Central Air Conditioners and Heat Pumps, as amended from time to time. (appendice M1 10 C.F.R.)

s. 186.1 — Type

For the purposes of these Regulations, a central heat pump manufactured on or after January 1, 2023 is one of the following types:

single package, other than space-constrained;

space-constrained single package;

split system, other than space-constrained or small-duct and high-velocity;

small-duct and high-velocity split-system; or

space-constrained split-system.

Ground-Source Heat Pumps

s. 187 — Definitions

The following definitions apply in this Subdivision.

CSA C446-94 means the CSA standard CAN/CSA-C446-94 entitled Performance of Ground-Source Heat Pumps. (CSA C446-94)

ground-source heat pump means a single package or split-system heat pump that is factory-built, has a cooling or heating capacity of less than 40 kW (135,000 Btu/h) and is intended for application in an open- or closed-loop ground-source system. (thermopompe géothermique)

s. 188 — Energy-using product

A ground-source heat pump is prescribed as an energy-using product.

s. 188(2) — Limit

However, for the purposes of sections 4, 5 and 189, a ground-source heat pump is not considered to be an energy-using product unless it is manufactured on or after February 3, 1995.

s. 189 — Energy efficiency standards

The energy efficiency standards set out in column 2 of the table to this section apply to ground-source heat pumps that are manufactured during the periods set out in column 3.

s. 189(2) — Testing standard

A ground source heat pump complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by the standard set out in column 1 that are applicable to a ground source heat pump as defined in section 187. TABLE Column 1 Column 2 Column 3 Item Testing Standard Energy Efficiency Standard Period of Manufacture 1 CSA C446-94 CSA C446-94, Table 2 On or after February 3, 1995 and before June 1, 2006 2 CSA C13256-1 On or after June 1, 2006

s. 190 — Information

For the purpose of subsection 5(1) of the Act, the following information must be provided to the Minister in respect of a ground-source heat pump:

its AHRI type classification;

its cooling capacity, expressed in kilowatts (British thermal units per hour);

its cooling coefficient of performance;

its heating capacity, expressed in kilowatts (British thermal units per hour);

its heating coefficient of performance; and

the ground-source system for which the product is intended, namely, open-loop, closed-loop or both open-loop and closed-loop.

s. 190(2) — Standard

The information must be collected in accordance with

CSA C446-94, if the product was manufactured on or after February 3, 1995 and before June 1, 2006; or

CSA C13256-1, if the product is manufactured on or after June 1, 2006.

Internal Water Loop Heat Pumps

s. 191 — Definition of internal water loop heat pump

In this Subdivision, internal water loop heat pump means a water-source single package or split-system heat pump that is factory-built, is intended for installation in an internal water loop system and has a cooling or heating capacity of not more than 40 kW (135,000 Btu/h).

s. 192 — Energy-using product

An internal water loop heat pump is prescribed as an energy-using product.

s. 192(2) — Limit

However, for the purposes of sections 4, 5 and 193, an internal water loop heat pump is not considered to be an energy-using product unless it is manufactured on or after February 3, 1995.

s. 193 — Energy efficiency standards

The energy efficiency standards set out in column 2 of the table to this section apply to internal water loop heat pumps described in column 1.

s. 193(2) — Testing standard

An internal water loop heat pump complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by CSA C13256-1 that are applicable to an internal water loop heat pump as defined in section 191. TABLE Column 1 Column 2 Item Energy-using Product Energy Efficiency Standard 1 Internal water loop heat pumps that have a cooling capacity of < 5 kW 2 Internal water loop heat pumps that have a cooling capacity of ≥ 5 kW but ≤ 40 kW

s. 194 — Information

For the purpose of subsection 5(1) of the Act, the following information must be collected in accordance with CSA C13256-1 and provided to the Minister in respect of an internal water loop heat pump:

its AHRI type classification;

its voltage;

its cooling capacity, expressed in kilowatts (British thermal units per hour);

its cooling coefficient of performance with 30°C inlet water;

its heating capacity, expressed in kilowatts (British thermal units per hour); and

its heating coefficient of performance with 20°C inlet water.

Large Heat Pumps

s. 195 — Definitions

The following definitions apply in this Subdivision.

AHRI 340/360 means the AHRI standard ANSI/AHRI 340/360-2007 entitled Performance Rating of Commercial and Industrial Unitary Air-Conditioning and Heat Pump Equipment. (AHRI 340/360)

CSA C746-17 means the CSA standard CAN/CSA-C746-17 entitled Energy performance rating for large and single packaged vertical air conditioners and heat pumps. (CSA C746-17)

CSA C746-98 means the CSA standard CAN/CSA-C746-98 entitled Performance Standard for Rating Large Air Conditioners and Heat Pumps. (CSA C746-98)

IEER means the integrated energy efficiency ratio, expressed in British thermal units per watt hour, that constitutes a single number cooling part-load efficiency metric of a large heat pump. (IEER)

large heat pump means a commercial or industrial unitary heat pump that is intended for air-conditioning and space-heating applications and that has a cooling capacity of at least 19 kW (65,000 Btu/h) but less than 223 kW (760,000 Btu/h). It does not include a single package vertical heat pump. (thermopompe de grande puissance)

10 C.F.R. Appendix A means Appendix A to Subpart F, Part 431 of Title 10 to the United States Code of Federal Regulations, entitled Uniform Test Method for the Measurement of Energy Consumption of Air-Cooled Small (≥65,000 Btu/h), Large, and Very Large Commercial Package Air Conditioning and Heating Equipment, as amended from time to time. (appendice A 10 C.F.R.)

s. 196 — Energy-using product

A large heat pump is prescribed as an energy-using product.

s. 196(2) — Limits

However, for the purposes of sections 4, 5 and 197, a large heat pump is not considered to be an energy-using product unless

in the case of a large heat pump with a cooling capacity that is less than 70 kW, it is manufactured on or after December 31, 1998; and

in the case of a large heat pump with a cooling capacity that is greater than or equal to 70 kW, it is manufactured on or after January 1, 2010.

s. 197 — Energy efficiency standards

The energy efficiency standards set out in column 3 of Table 1 to this section apply to large heat pumps described in column 1 that are manufactured during the periods set out in column 4 and that have no heating section or have an electric heating section.

s. 197(2) — Energy efficiency standards

The energy efficiency standards set out in column 3 of Table 2 to this section apply to large heat pumps described in column 1 that are manufactured during the periods set out in column 4 and that have a heating section other than an electric heating section.

s. 197(3) — Testing standard

A large heat pump complies with the energy efficiency standard set out in column 3 if it meets that standard when tested in accordance with testing procedures established by the standard set out in column 2 that are applicable to a large heat pump as defined in section 195. TABLE 1 Column 1 Column 2 Column 3 Column 4 Item Energy-using Product Testing Standard Energy Efficiency Standard Period of Manufacture 1 Large heat pumps that have a cooling capacity of ≥ 19 kW and < 40 kW CSA C746-98 On or after December 31, 1998 and before January 1, 2010 2 Large heat pumps that have a cooling capacity of ≥ 19 kW and < 40 kW On or after January 1, 2010 and before January 1, 2018 3 Large heat pumps that have a cooling capacity of ≥ 19 kW and < 40 kW CSA C746-17 On or after January 1, 2018 and before January 1, 2026 4 Large heat pumps that have a cooling capacity of ≥ 19 kW and < 40 kW CSA C746-17 or 10 C.F.R. Appendix A On or after January 1, 2026 5 Large heat pumps that have a cooling capacity of ≥ 40 kW and < 70 kW CSA C746-98 On or after December 31, 1998 and before January 1, 2010 6 Large heat pumps that have a cooling capacity of ≥ 40 kW and < 70 kW On or after January 1, 2010 and before January 1, 2018 7 Large heat pumps that have a cooling capacity of ≥ 40 kW and < 70 kW CSA C746-17 On or after January 1, 2018 and before January 1, 2026 8 Large heat pumps that have a cooling capacity of ≥ 40 kW and < 70 kW CSA C746-17 or 10 C.F.R. Appendix A On or after January 1, 2026 9 Large heat pumps that have a cooling capacity of ≥ 70 kW and < 223 kW On or after January 1, 2010 and before January 1, 2018 10 Large heat pumps that have a cooling capacity of ≥ 70 kW and < 223 kW CSA C746-17 On or after January 1, 2018 and before January 1, 2026 11 Large heat pumps that have a cooling capacity of ≥ 70 kW and < 223 kW CSA C746-17 or 10 C.F.R. Appendix A On or after January 1, 2026 TABLE 2 Column 1 Column 2 Column 3 Column 4 Item Energy-using Product Testing Standard Energy Efficiency Standard Period of Manufacture 1 Large heat pumps that have a cooling capacity of ≥ 19 kW and < 40 kW CSA C746-98 On or after December 31, 1998 and before January 1, 2010 2 Large heat pumps that have a cooling capacity of ≥ 19 kW and < 40 kW On or after January 1, 2010 and before January 1, 2018 3 Large heat pumps that have a cooling capacity of ≥ 19 kW and < 40 kW CSA C746-17 On or after January 1, 2018 and before January 1, 2026 4 Large heat pumps that have a cooling capacity of ≥ 19 kW and < 40 kW CSA C746-17 or 10 C.F.R. Appendix A On or after January 1, 2026 5 Large heat pumps that have a cooling capacity of ≥ 40 kW and < 70 kW CSA C746-98 On or after December 31, 1998 and before January 1, 2010 6 Large heat pumps that have a cooling capacity of ≥ 40 kW and < 70 kW On or after January 1, 2010 and before January 1, 2018 7 Large heat pumps that have a cooling capacity of ≥ 40 kW and < 70 kW CSA C746-17 On or after January 1, 2018 and before January 1, 2026 8 Large heat pumps that have a cooling capacity of ≥ 40 kW and < 70 kW CSA C746-17 or 10 C.F.R. Appendix A On or after January 1, 2026 9 Large heat pumps that have a cooling capacity of ≥ 70 kW and < 223 kW On or after January 1, 2010 and before January 1, 2018 10 Large heat pumps that have a cooling capacity of ≥ 70 kW and < 223 kW CSA C746-17 On or after January 1, 2018 and before January 1, 2026 11 Large heat pumps that have a cooling capacity of ≥ 70 kW and < 223 kW CSA C746-17 or 10 C.F.R. Appendix A On or after January 1, 2026

s. 198 — Information

For the purpose of subsection 5(1) of the Act, the information set out in column 3 of the table to this section must be collected in accordance with the standard set out in column 2 and provided to the Minister in respect of a large heat pump described in column 1. TABLE Column 1 Column 2 Column 3 Item Energy-using Product Testing Standard Information 1 Large heat pumps manufactured on or after December 31, 1998 and before January 1, 2010 CSA C746-98 2 Large heat pumps manufactured on or after January 1, 2010 and before January 1, 2018 3 Large heat pumps manufactured on or after January 1, 2018 and before January 1, 2026 CSA C746-17 4 Large heat pumps manufactured on or after January 1, 2026 CSA C746-17 or 10 C.F.R. Appendix A

Packaged Terminal Heat Pumps

s. 199 — Definitions

The following definitions apply in this Subdivision.

CSA C744-04 means the joint CSA and AHRI standard ANSI/AHRI 310/380-2004/CAN/CSA-C744-04 entitled Standard for Packaged Terminal Air Conditioners and Heat Pumps. (CSA C744-04)

CSA C744-17 means the joint CSA and AHRI standard ANSI/AHRI 310/380-2017/CSA-C744-17 entitled Packaged terminal air conditioners and heat pumps. (CSA C744-17)

packaged terminal heat pump means a factory-built packaged heat pump that consists of a separate unencased refrigeration system and uses reverse cycle refrigeration as its primary heat source. (thermopompe terminale autonome)

s. 200 — Energy-using product

A packaged terminal heat pump is prescribed as an energy-using product.

s. 200(2) — Limit

However, for the purposes of sections 4, 5 and 201, a packaged terminal heat pump is not considered to be an energy-using product unless it is manufactured on or after December 31, 1998.

s. 201 — Energy efficiency standards

The energy efficiency standards set out in column 2 of the table to this section apply to packaged terminal heat pumps that are manufactured during the periods set out in column 3.

s. 201(2) — Testing standard

A packaged terminal heat pump complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by the standard set out in column 1 that are applicable to a packaged terminal heat pump as defined in section 199. TABLE Column 1 Column 2 Column 3 Item Testing Standard Energy Efficiency Standard Period of Manufacture 1 CSA C744-04 CSA C744-04, Table 2 On or after December 31, 1998 and before September 30, 2012 2 CSA C744-17 CSA C744-17, Table 2 On or after September 30, 2012

s. 202 — Information

For the purpose of subsection 5(1) of the Act, the following information must be provided to the Minister in respect of a packaged terminal heat pump:

its cooling capacity, expressed in kilowatts (British thermal units per hour);

its energy efficiency ratio;

its heating capacity, expressed in kilowatts (British thermal units per hour);

its heating coefficient of performance; and

if applicable, identification of the product as a replacement unit.

s. 202(2) — Standard

The information must be collected in accordance with

CSA C744-04, if the product was manufactured on or after December 31, 1998 and before September 30, 2012; or

CSA C744-17, if the product is manufactured on or after September 30, 2012.

Single Package Central Heat Pumps

s. 203 — Definitions

The following definitions apply in this Subdivision.

off mode power consumption means the power consumption when the unit is connected to mains power but is not providing cooling or heating. (consommation d’énergie en mode arrêt)

single package central heat pump means a single-phase or three-phase air-to-air central heat pump that is a single package unit and that has a cooling capacity of less than 19 kW (65,000 Btu/h), but does not include a single package vertical heat pump. (thermopompe centrale monobloc)

single package heat pump[Repealed, SOR/2022-265, s. 15]

through-the-wall means, in respect of a single package central heat pump, one that has a cooling capacity less than or equal to 8.79 kW (30,000 Btu/h), that is designed to be installed through an exterior wall and that is manufactured prior to January 1, 2023. (murale)

s. 204 — Energy-using product

A single package central heat pump is prescribed as an energy-using product.

s. 204(2) — Limit

However, for the purposes of sections 4, 5 and 205, a single package central heat pump is not considered to be an energy-using product unless it is manufactured on or after February 3, 1995.

s. 205 — Energy efficiency standards — single-phase

The energy efficiency standards set out in column 3 of Table 1 to this section apply to single-phase single package central heat pumps described in column 1 that are manufactured during the periods set out in column 4.

s. 205(1.1) — Energy efficiency standards — three-phase

The energy efficiency standards set out in column 3 of Table 2 to this section apply to three-phase single package central heat pumps described in column 1 that are manufactured during the periods set out in column 4.

s. 205(2) — Testing standard

A single package central heat pump complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by the standard set out in column 2 that are applicable to a single package central heat pump as defined in section 203. TABLE 1 Column 1 Column 2 Column 3 Column 4 Item Energy-using Product Testing Standard Energy Efficiency Standard Period of Manufacture 1 Single package central heat pumps, other than those that are through-the-wall or small-duct and high-velocity On or after February 3, 1995 and before January 1, 2023 2 Single package central heat pumps that are through-the-wall On or after February 3, 1995 and before January 1, 2023 3 Single package central heat pumps that are small-duct and high-velocity On or after February 3, 1995 and before January 1, 2023 4 Single package central heat pumps, other than those that are space-constrained 10 C.F.R. Appendix M1 On or after January 1, 2023 and before January 1, 2025 5 Single package central heat pumps that are space-constrained 10 C.F.R. Appendix M1 On or after January 1, 2023 and before January 1, 2025 6 Single package central heat pumps, other than those that are space-constrained 10 C.F.R. Appendix M1, except that the very low temperature heating test (H4) must be conducted On or after January 1, 2025 7 Single package central heat pumps that are space-constrained 10 C.F.R. Appendix M1, except that the very low temperature heating test (H4) must be conducted On or after January 1, 2025 TABLE 2 Column 1 Column 2 Column 3 Column 4 Item Energy-using Product Testing Standard Energy Efficiency Standard Period of Manufacture 1 Single package central heat pumps, other than those that are through-the-wall or small-duct and high-velocity CSA C656-14 On or after February 3, 1995 and before January 1, 2023 2 Single package central heat pumps that are through-the-wall CSA C656-05 On or after February 3, 1995 and before January 1, 2023 3 Single package central heat pumps that are small-duct and high-velocity CSA C656-14 On or after February 3, 1995 and before January 1, 2023 4 Single package central heat pumps, other than those that are space-constrained CSA C656-14 On or after January 1, 2023 and before January 1, 2026 5 Single package central heat pumps that are space-constrained CSA C656-14 On or after January 1, 2023 and before January 1, 2026 6 Single package central heat pumps, other than those that are space-constrained 10 C.F.R. Appendix F1, except that the very low temperature heating test (H4) must be conducted On or after January 1, 2026 7 Single package central heat pumps that are space-constrained 10 C.F.R. Appendix F1, except that the very low temperature heating test (H4) must be conducted On or after January 1, 2026

s. 206 — Information

For the purpose of subsection 5(1) of the Act, the information set out in column 3 of the table to this section must be collected and provided to the Minister in respect of a single package central heat pump described in column 1 and, if applicable, the information must be collected in accordance with the standard set out in column 2. TABLE Column 1 Column 2 Column 3 Item Energy-using Product Testing Standard Information 1 Single package central heat pumps that are single-phase, other than those that are through-the-wall, manufactured on or after February 3, 1995 and before January 1, 2023 2 Single package central heat pumps that are three-phase, other than those that are through-the-wall, manufactured on or after February 3, 1995 and before January 1, 2023 CSA C656-14 for information set out in paragraphs (a) to (e) 3 Single package central heat pumps that are single-phase, through-the-wall and manufactured on or after February 3, 1995 and before January 1, 2023 4 Single package central heat pumps that are three-phase, through-the-wall and manufactured on or after February 3, 1995 and before January 1, 2023 CSA C656-05 for information set out in paragraphs (a) to (e) 5 Single package central heat pumps that are single-phase and manufactured on or after January 1, 2023 and before January 1, 2025 10 C.F.R. Appendix M1 for information set out in paragraphs (b) to (i) 6 Single package central heat pumps that are single-phase and manufactured on or after January 1, 2025 10 C.F.R. Appendix M1, except that the very low temperature heating test (H4) must be conducted for information set out in paragraphs (b) to (h) 7 Single package central heat pumps that are three-phase and manufactured on or after January 1, 2023 and before January 1, 2026 CSA C656-14 for information set out in paragraphs (a) to (e) 8 Single package central heat pumps that are three-phase and manufactured on or after January 1, 2026 10 C.F.R. Appendix F1, except that the very low temperature heating test (H4) must be conducted for information set out in paragraphs (b) to (g)

s. 206.1 — Early compliance

A single package central heat pump that is manufactured on or after January 1, 2025 and before January 1, 2026 is deemed to satisfy the requirements of sections 205 and 206 if it satisfies the requirements of those sections that would have applied to the single package central heat pump if it had been manufactured on or after January 1, 2026.

Single Package Vertical Heat Pumps

s. 207 — Definition of single package vertical heat pump

In this Subdivision, single package vertical heat pump means a single package commercial heat pump that is encased, that has its major components arranged vertically and that

is air-cooled and uses reverse cycle refrigeration as its primary heat source; and

is intended for mounting through, or on either side of, an exterior wall.

s. 208 — Energy-using product

A single package vertical heat pump is prescribed as an energy-using product.

s. 208(2) — Limit

However, for the purposes of sections 4, 5 and 209, a single package vertical heat pump is not considered to be an energy-using product unless it is manufactured on or after January 1, 2011 and has a cooling capacity of less than 70 kW (240,000 Btu/h).

s. 209 — Energy efficiency standards

The energy efficiency standards set out in column 2 of the table to this section apply to single package vertical heat pumps described in column 1 that are manufactured during the periods set out in column 3.

s. 209(2) — Testing standard

A single package vertical heat pump complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by CSA C746-17 that are applicable to a single package vertical heat pump as defined in section 207. TABLE Item Column 1 Column 2 Column 3 Energy-using Product Energy Efficiency Standard Period of manufacture 1 Single package vertical heat pumps that have a cooling capacity of < 19 kW (65,000 Btu/h) On or after January 1, 2011 and before September 23, 2019 2 Single package vertical heat pumps that have a cooling capacity of < 19 kW (65,000 Btu/h) On or after September 23, 2019 3 Single package vertical heat pumps that have a cooling capacity of ≥ 19 kW (65,000 Btu/h) and < 39.5 kW (135,000 Btu/h) On or after January 1, 2011 and before October 9, 2015 4 Single package vertical heat pumps that have a cooling capacity of ≥ 19 kW (65,000 Btu/h) and < 39.5 kW (135,000 Btu/h On or after October 9, 2015 5 Single package vertical heat pumps that have a cooling capacity of ≥ 39.5 kW (135,000 Btu/h) and < 70 kW (240,000 Btu/h) On or after January 1, 2011 and before October 9, 2016 6 Single package vertical heat pumps that have a cooling capacity of ≥ 39.5 kW (135,000 Btu/h) and < 70 kW (240,000 Btu/h) On or after October 9, 2016

s. 210 — Information

For the purpose of subsection 5(1) of the Act, the following information must be collected in accordance with CSA C746-17 and provided to the Minister in respect of a single package vertical heat pump:

its classification set out in columns II and III of Table 2 to CSA C746-17;

its cooling capacity, expressed in kilowatts (British thermal units per hour);

its energy efficiency ratio;

its heating capacity, expressed in kilowatts (British thermal units per hour); and

its heating coefficient of performance.

Split System Central Heat Pumps

s. 211 — Definitions

The following definitions apply in this Subdivision.

off mode power consumption means the power consumption when the unit is connected to mains power but is not providing cooling or heating. (consommation d’énergie en mode arrêt)

split system central heat pump means a single-phase or three-phase air-to-air central heat pump that is a split system and that has a cooling capacity of less than 19 kW (65,000 Btu/h). (thermopompe centrale bibloc)

split-system heat pump[Repealed, SOR/2022-265, s. 19]

s. 212 — Energy-using product

A split system central heat pump is prescribed as an energy-using product.

s. 212(2) — Limit

However, for the purposes of sections 4, 5 and 213, a split system central heat pump is not considered to be an energy-using product unless it is manufactured on or after December 31, 1998.

s. 213 — Energy efficiency standards — single-phase

The energy efficiency standards set out in column 3 of Table 1 to this section apply to single-phase split system central heat pumps described in column 1 that are manufactured during the periods set out in column 4.

s. 213(1.1) — Energy efficiency standards — three-phase

The energy efficiency standards set out in column 3 of Table 2 to this section apply to three-phase split system central heat pumps described in column 1 that are manufactured during the periods set out in column 4.

s. 213(2) — Testing standard

A split system central heat pump complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by the standard set out in column 2 that are applicable to a split system central heat pump as defined in section 211. TABLE 1 Column 1 Column 2 Column 3 Column 4 Item Energy-using Product Testing Standard Energy Efficiency Standard Period of Manufacture 1 Split system central heat pumps, other than those that are small-duct and high-velocity On or after December 31, 1998 and before January 1, 2023 2 Split system central heat pumps that are small-duct and high-velocity On or after December 31, 1998 and before January 1, 2023 3 Split system central heat pumps, other than those that are small-duct and high-velocity or space-constrained 10 C.F.R. Appendix M1 On or after January 1, 2023 and before January 1, 2025 4 Split system central heat pumps that are small-duct and high-velocity 10 C.F.R. Appendix M1 On or after January 1, 2023 and before January 1, 2025 5 Split system central heat pumps that are space-constrained 10 C.F.R. Appendix M1 On or after January 1, 2023 and before January 1, 2025 6 Split system central heat pumps, other than those that are small-duct and high-velocity or space-constrained 10 C.F.R. Appendix M1 with the very low temperature heating test (H4) conducted at -15°C (5°F) On or after January 1, 2025 7 Split system central heat pumps that are small-duct and high-velocity 10 C.F.R. Appendix M1 with the very low temperature heating test (H4) conducted at -15°C (5°F) On or after January 1, 2025 8 Split system central heat pumps that are space-constrained 10 C.F.R. Appendix M1 with the very low temperature heating test (H4) conducted at -15°C (5°F) On or after January 1, 2025 TABLE 2 Column 1 Column 2 Column 3 Column 4 Item Energy-using Product Testing Standard Energy Efficiency Standard Period of Manufacture 1 Split system central heat pumps, other than those that are small-duct and high-velocity CSA C656-14 On or after December 31, 1998 and before January 1, 2026 2 Split system central heat pumps that are small-duct and high-velocity CSA C656-14 On or after December 31, 1998 and before January 1, 2026 3 Split system central heat pumps, other than those that are space-constrained or small-duct and high-velocity 10 C.F.R. Appendix F1, except that the very low temperature heating test (H4) must be conducted On or after January 1, 2026 4 Split system central heat pumps that are space-constrained 10 C.F.R. Appendix F1, except that the very low temperature heating test (H4) must be conducted On or after January 1, 2026 5 Split system central heat pumps that are small-duct and high-velocity 10 C.F.R. Appendix F1, except that the very low temperature heating test (H4) must be conducted On or after January 1, 2026

s. 214 — Information

For the purposes of subsection 5(1) of the Act, the information set out in column 3 of the table to this section must be collected and provided to the Minister in respect of a split system central heat pump described in column 1 and, if applicable, the information must be collected in accordance with the standard set out in column 2. TABLE Column 1 Column 2 Column 3 Item Energy-using Product Testing Standard Information 1 Split system central heat pumps that are single-phase and manufactured on or after December 31, 1998 and before January 1, 2023 2 Split system central heat pumps that are single-phase and manufactured on or after January 1, 2023 and before January 1, 2025 10 C.F.R. Appendix M1 for information set out in paragraphs (b) to (i) 3 Split system central heat pumps that are single-phase and manufactured on or after January 1, 2025 10 C.F.R. Appendix M1, except that the very low temperature heating test (H4) must be conducted for information set out in paragraphs (b) to (h) 4 Split system central heat pumps that are three-phase and manufactured on or after December 31, 1998 and before January 1, 2026 CSA C656-14 for information set out in paragraphs (a) to (e) 5 Split system central heat pumps that are three-phase and manufactured on or after January 1, 2026 10 C.F.R. Appendix F1, except that the very low temperature heating test (H4) must be conducted for information set out in paragraphs (b) to (g)

s. 214.1 — Early compliance

A split system central heat pump that is manufactured on or after January 1, 2025 and before January 1, 2026 is deemed to satisfy the requirements of sections 213 and 214 if it satisfies the requirements of those sections that would have applied to the split system central heat pump if it had been manufactured on or after January 1, 2026.

Furnaces, Fireplaces, Unit Heaters and Recovery Ventilators

Interpretation

s. 256.1 — Definitions

The following definitions apply in this Division.

CSA P.2 means the CSA standard CAN/CSA-P.2-13 entitled Testing method for measuring the annual fuel utilization efficiency of residential gas-fired or oil-fired furnaces and boilers. (CSA P.2)

FER means, in respect of a gas furnace, an oil-fired furnace or an electric furnace, the fan energy rating, which is the annual electrical energy consumption of the furnace fan normalized by annual fan operating hours and the product’s maximum airflow (Q max). (FER)

10 C.F.R. Appendix AA means Appendix AA to Subpart B of Part 430 of Title 10 to the United States Code of Federal Regulations, entitled Uniform Test Method for Measuring the Energy Consumption of Furnace Fans, as amended from time to time. (appendice AA 10 C.F.R.)

10 C.F.R. §430.32(y) means Table 1 to paragraph 430.32(y) of Subpart C, Part 430 of Title 10 to the United States Code of Federal Regulations, as amended from time to time. (10 C.F.R. §430.32(y))

Gas Furnaces

s. 257 — Definitions

The following definitions apply in this Subdivision.

CSA 2.3 means the CSA standard ANSI Z21.47-2016/CSA 2.3-2016 entitled Gas-Fired Central Furnaces. (CSA 2.3)

CSA P.2[Repealed, SOR/2018-201, s. 34]

gas furnace means an automatic operating gas-fired central forced air furnace that uses propane or natural gas and has an input rate of not more than 117.23 kW (400,000 Btu/h). It does not include a furnace for a park model trailer or a recreational vehicle. (générateur d’air chaud à gaz)

gas furnace for relocatable buildings means a gas furnace that is intended for use in a temporary modular building that can be relocated from one site to another and is marked for use in relocatable buildings. (générateur d’air chaud à gaz pour bâtiments relocalisables)

manufactured home means a factory-built, single- or multiple-section, one-storey dwelling that

is designed and constructed for year-round occupancy;

is designed to be transported to its installation site; and

is ready for occupancy when it is installed in accordance with the manufacturer’s installation instructions. (maison usinée)

replacement non-condensing gas furnace means a non-condensing gas furnace that is marked for use as a replacement for a non-condensing gas furnace in a manufactured home. (générateur d’air chaud à gaz sans condensation de remplacement)

space-constrained, with respect to a gas furnace, means one that

uses single-phase electric current; and

has an outdoor or indoor unit

that has an overall displacement that is — or two or more overall exterior dimensions that are — substantially smaller than those of other units of a similar heating capacity that are usually installed in single-family homes, and

with respect to which an increase in the overall displacement or two or more overall exterior dimensions would result in a considerable increase in the usual cost of installation or in a significant loss in the utility of the product to the consumer. (à espace restreint)

through-the-wall means, with respect to a gas furnace, one that is designed and marketed to be installed in an opening in an exterior wall that is fitted with a weatherized sleeve. (mural)

s. 258 — Energy-using product

A gas furnace is prescribed as an energy-using product.

s. 258(2) — Limits

However, for the purposes of sections 4, 5 and 259, a gas furnace is not considered to be an energy-using product if

it was manufactured before February 3, 1995;

it is a gas furnace for relocatable buildings that is manufactured before July 3, 2019; or

it is a replacement non-condensing gas furnace that is manufactured before July 3, 2019.

s. 259 — Energy efficiency standards

The energy efficiency standards set out in column 3 of the table to this section apply to gas furnaces described in column 1 that are manufactured during the periods set out in column 4.

s. 259(2) — Testing standard

A gas furnace complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by the standard set out in column 2 that are applicable to a gas furnace as defined in section 257. TABLE Column 1 Column 2 Column 3 Column 4 Item Energy-using Product Testing Standard Energy Efficiency Standard Period of Manufacture 1 Gas furnaces that have an input rate of ≤ 65.92 kW (225,000 Btu/h) and use single-phase electric current CSA 2.3 Annual fuel utilization efficiency ≥ 78%On or after February 3, 1995 and before December 31, 2009 2 Gas furnaces that have an input rate of ≤ 65.92 kW (225,000 Btu/h), use single-phase electric current and do not have an integrated cooling component CSA P.2 Annual fuel utilization efficiency ≥ 90%On or after December 31, 2009 and before July 3, 2019 2.1 Gas furnaces, other than gas furnaces for relocatable buildings or replacement non-condensing gas furnaces, that have an input rate of ≤ 65.92 kW (225,000 Btu/h), use single-phase electric current and do not have an integrated cooling component On or after July 3, 2019 3 Gas furnaces that are outdoor furnaces, have an input rate of ≤ 65.92 kW (225,000 Btu/h), use single-phase electric current and have an integrated cooling component CSA P.2 Annual fuel utilization efficiency ≥ 78%On or after December 31, 2009 and before July 3, 2019 3.1 Gas furnaces that are outdoor furnaces, have an input rate of ≤ 65.92 kW (225,000 Btu/h), use single-phase electric current and have an integrated cooling component On or after July 3, 2019 4 Gas furnaces that are through-the-wall, have an input rate of ≤ 65.92 kW (225,000 Btu/h), use single-phase electric current and have an integrated cooling component CSA P.2 Annual fuel utilization efficiency ≥ 78%On or after December 31, 2009 and before December 31, 2012 5 Gas furnaces, other than gas furnaces for relocatable buildings or replacement non-condensing gas furnaces, that are through-the-wall, have an input rate of ≤ 65.92 kW (225,000 Btu/h), use single-phase electric current and have an integrated cooling component CSA P.2 Annual fuel utilization efficiency ≥ 90%On or after December 31, 2012 and before January 1, 2024 5.1 Gas furnaces, other than gas furnaces for relocatable buildings or replacement non-condensing gas furnaces, that are space-constrained, have an input rate of ≤ 65.92 kW (225,000 Btu/h) and have an integrated cooling component CSA P.2 Annual fuel utilization efficiency ≥ 90%On or after January 1, 2024 6 Gas furnaces that have an input rate of ≤ 65.92 kW (225,000 Btu/h) and use three-phase electric current CSA 2.3 On or after February 3, 1995 7 Gas furnaces that have an input rate of > 65.92 kW (225,000 Btu/h) but ≤ 117.23 kW (400,000 Btu/h) CSA 2.3 Thermal efficiency ≥ 80%On or after February 3, 1995 8 Gas furnaces for relocatable buildings On or after July 3, 2019 9 Replacement non-condensing gas furnaces On or after July 3, 2019

s. 260 — Information

For the purpose of subsection 5(1) of the Act, the information set out in column 3 of the table to this section must be collected in accordance with the standard set out in column 2 and provided to the Minister in respect of a gas furnace described in column 1. TABLE Column 1 Column 2 Column 3 Item Energy-using Product Testing Standard Information 1 Gas furnaces that have an input rate of ≤ 65.92 kW (225,000 Btu/h), that use single-phase electric current and that are manufactured before December 31, 2009 CSA 2.3 2 Gas furnaces, other than those that are through-the-wall, that have an input rate of ≤ 65.92 kW (225,000 Btu/h), that use single-phase electric current and that are manufactured on or after December 31, 2009 and before July 3, 2019 CSA P.2 2.1 Gas furnaces that have an input rate of ≤ 65.92 kW (225,000 Btu/h), that use single-phase electric current and that are manufactured on or after July 3, 2019 2.2 Gas furnaces that are through-the-wall, that have an input rate of ≤ 65.92 kW (225,000 Btu/h), that use single-phase electric current, that have an integrated cooling component and that are manufactured on or after December 31, 2009 and before January 1, 2024 CSA P.2 for information set out in paragraphs (a) to (c) 2.3 Gas furnaces, other than gas furnaces for relocatable buildings or replacement non-condensing gas furnaces, that are space-constrained, that have an input rate of ≤ 65.92 kW (225,000 Btu/h), that have an integrated cooling component and that are manufactured on or after January 1, 2024 CSA P.2 for information set out in paragraphs (a) to (c) 3 Gas furnaces that have an input rate of ≤ 65.92 kW (225,000 Btu/h) and that use three-phase electric current CSA 2.3 4 Gas furnaces that have an input rate of > 65.92 kW (225,000 Btu/h) but ≤ 117.23 kW (400,000 Btu/h) CSA 2.3 5 Gas furnaces for relocatable buildings manufactured on or after January 1, 2024 6 Replacement non-condensing gas furnaces manufactured on or after January 1, 2024

[Repealed]

Oil-Fired Furnaces

s. 261 — Definitions

The following definitions apply in this Subdivision.

CSA B212 means the CSA standard CSA-B212-93 entitled Seasonal Energy Utilization Efficiencies of Oil-Fired Furnaces and Boilers. (CSA B212)

oil-fired furnace means a warm-air furnace, other than a furnace for a mobile home or for a recreational vehicle, that has an input rate of not more than 65.92 kW (225,000 Btu/h) and that is either

exclusively oil-fired; or

capable of being fired, at the choice of the user, by either oil or another fuel. (générateur d’air chaud à mazout)

s. 262 — Energy-using product

An oil-fired furnace is prescribed as an energy-using product.

s. 262(2) — Limit

However, for the purposes of sections 4, 5 and 263, an oil-fired furnace is not considered to be an energy-using product unless it is manufactured on or after December 31, 1998.

s. 263 — Energy efficiency standards

The energy efficiency standards set out in column 2 of the table to this section apply to oil-fired furnaces that are manufactured during the periods set out in column 3.

s. 263(2) — Testing standard

An oil-fired furnace complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by the standard set out in column 1 that are applicable to an oil-fired furnace as defined in section 261. TABLE Column 1 Column 2 Column 3 Item Testing Standard Energy Efficiency Standard Period of Manufacture 1 CSA B212 Seasonal energy utilization efficiency ≥ 78%On or after December 31, 1998 and before January 1, 2017 2 CSA P.2 Annual fuel utilization efficiency ≥ 83%On or after January 1, 2017 and before July 3, 2019 3 On or after July 3, 2019

s. 264 — Information

For the purpose of subsection 5(1) of the Act, the information set out in column 3 of the table to this section must be collected in accordance with the standard set out in column 2 and provided to the Minister in respect of an oil-fired furnace described in column 1. TABLE Column 1 Column 2 Column 3 Item Energy-using Product Testing Standard Information 1 Oil-fired furnaces that are manufactured on or after December 31, 1998 and before January 1, 2017 CSA B212 2 Oil-fired furnaces that are manufactured on or after January 1, 2017 and before July 3, 2019 CSA P.2 3 Oil-fired furnaces that are manufactured on or after July 3, 2019

Gas Fireplaces

s. 265 — Definitions

The following definitions apply in this Subdivision.

CSA P.4.1 means the CSA standard CAN/CSA P.4.1-02 entitled Testing Method for Measuring Annual Fireplace Efficiency. (CSA P.4.1)

CSA P.4.1-15 means the CSA standard CAN/CSA P.4.1-15 entitled Testing Method for Measuring Annual Fireplace Efficiency. (CSA P.4.1-15)

decorative gas fireplace means a vented fireplace that is fuelled by natural gas or propane, is marked for decorative use only and is not equipped with a thermostat or intended for use as a heater. (foyer à gaz décoratif)

gas fireplace means a decorative gas fireplace or a heating gas fireplace. (foyer à gaz)

heating gas fireplace means a vented fireplace that is fuelled by natural gas or propane and is not a decorative gas fireplace. (foyer à gaz de chauffage)

s. 266 — Energy-using product

A gas fireplace is prescribed as an energy-using product.

s. 266(2) — Limits

However, a gas fireplace is not considered to be an energy-using product

for the purposes of sections 4, 5 and 7, unless it is manufactured on or after June 1, 2003; or

for the purpose of section 266.1, unless it is manufactured on or after January 1, 2020.

s. 266.1 — Energy efficiency standards

The energy efficiency standards set out in column 3 of the table to this section apply to gas fireplaces described in column 1 that are manufactured during the periods set out in column 4.

s. 266.1(2) — Testing standard

A gas fireplace complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by the standard set out in column 2 that are applicable to a gas fireplace as defined in section 265. TABLE Item Column 1 Column 2 Column 3 Column 4 Energy-using Product Testing Standard Energy Efficiency Standard Period of Manufacture 1 Decorative gas fireplaces N\A On or after January 1, 2020 2 Heating gas fireplaces CSA P.4.1-15 for fireplace efficiency On or after January 1, 2020

s. 267 — Information

For the purpose of subsection 5(1) of the Act, the following information must be provided to the Minister in respect of a gas fireplace:

the type of fuel it uses;

its maximum and minimum input rates, expressed in kilowatts (British thermal units per hour);

the fireplace efficiency;

information that indicates whether it is freestanding, zero-clearance or an insert;

the type of ignition system it uses;

the venting configuration the product has, namely, natural venting, direct venting or powered venting;

information that indicates whether the product is a decorative gas fireplace or a heating gas fireplace; and

if the product is a decorative gas fireplace that is manufactured on or after January 1, 2020, information that indicates whether it is intended for use as a replacement unit.

s. 267(2) — Standard

The information must be collected in accordance with

CSA P.4.1, if the product was manufactured on or after June 1, 2003 and before January 1, 2017; or

CSA P.4.1-15, if the product is manufactured on or after January 1, 2017.

Gas-Fired Unit Heaters

s. 268 — Definitions

The following definitions apply in this Subdivision.

CSA P.11 means the CSA standard CAN/CSA-P.11-07 entitled Testing Method for Measuring Efficiency and Energy Consumption of Gas-fired Unit Heaters. (CSA P.11)

gas-fired unit heater means a self-contained, automatically controlled, vented, gas-burning appliance that distributes warmed air without the use of ducts and that has an input rate of not more than 2 931 kW (10,000,000 Btu/h). (aérotherme à gaz)

s. 269 — Energy-using product

A gas-fired unit heater is prescribed as an energy-using product.

s. 269(2) — Limit

However, for the purposes of sections 4, 5 and 270, a gas-fired unit-heater is not considered to be an energy-using product unless it is manufactured on or after August 8, 2008.

s. 270 — Energy efficiency standards

The following energy efficiency standards apply to a gas-fired unit heater:

its thermal efficiency must be at least 80% at the maximum heat input nominal capacity; and

it must be equipped with an intermittent ignition device and

a power-vented system,

an automatic vent damper, or

an automatic flue damper.

s. 270(2) — Testing standard

A gas-fired unit heater complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by CSA P.11 that are applicable to a gas-fired unit heater as defined in section 268.

s. 271 — Information

For the purpose of subsection 5(1) of the Act, the following information must be collected in accordance with CSA P.11 and provided to the Minister in respect of a gas-fired unit heater:

the type of fuel it uses;

the type of ignition system it has;

the venting configuration it has, namely, a power-vented system, an automatic vent damper or an automatic flue damper;

its maximum heat input and output nominal capacities, expressed in kilowatts;

its thermal efficiency when at the maximum heat input nominal capacity;

its electricity consumption, expressed in kilowatt hours, when at the maximum nominal heat input capacity; and

if it is a modulating or staged control gas-fired unit heater,

its reduced heat input and output nominal capacities, expressed in kilowatts, and

its electricity consumption, expressed in kilowatt hours, when at reduced heat input nominal capacity.

Electric Furnaces

s. 272 — Definition of electric furnace

In this Subdivision, electric furnace means an automatic operating central forced air furnace that uses single-phase electric current to heat one or more electrical resistance heating elements and has an input rate of not more than 65.92 kW (225,000 Btu/h). It does not include an electric furnace that

produces at least 300 Pa (1.2 inches of water) external static pressure when operated at an air volume rate of 104 to 165 L/s (220 to 350 ft 3/min) per nominal ton of cooling in the highest default cooling airflow-control setting; and

uses room outlets that produce velocities greater than 5 m/s (1,000 ft/min) and each have an area less than 39 cm 2 (6 square inches).

s. 273 — Energy-using product

An electric furnace is prescribed as an energy-using product.

s. 273(2) — Limit

However, for the purposes of sections 4, 5 and 274, an electric furnace is not considered to be an energy-using product unless it is manufactured on or after July 3, 2019.

s. 274 — Energy efficiency standard

The energy efficiency standard that applies to an electric furnace is that its FER must be less than or equal to the FER for product class “Non-Weatherized, Electric Furnace/Modular Blower Fan”, set out in 10 C.F.R. §430.32(y).

s. 274(2) — Testing standard

An electric furnace complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by 10 C.F.R. Appendix AA that are applicable to an electric furnace as defined in section 272.

s. 275 — Information

For the purpose of subsection 5(1) of the Act, the following information must be collected in accordance with 10 C.F.R. Appendix AA and provided to the Minister in respect of an electric furnace:

its maximum heat input nominal capacity, expressed in kilowatts (British thermal units per hour);

its FER, expressed in watts per 472 L/s (watts per 1000 ft 3/min); and

its maximum airflow (Q max), expressed in L/s (ft 3/min).

Recovery Ventilators

Interpretation

s. 276 — Definitions

The following definitions apply in this Subdivision.

CSA C439-18 means the CSA standard CAN/CSA-C439-18 entitled Laboratory methods of test for rating the performance of heat/energy-recovery ventilators. (CSA C439-18)

energy-recovery ventilator means a factory-built packaged unit that has fans or blowers, has a maximum rated airflow of not more than 142 L/s (300 ft 3/min) at 0°C and transfers heat and moisture between two isolated airstreams. (ventilateur-récupérateur d’énergie)

heat-recovery ventilator means a factory-built packaged unit that has fans or blowers, has a maximum rated airflow of not more than 142 L/s (300 ft 3/min) at 0°C and transfers heat between two isolated airstreams. (ventilateur-récupérateur de chaleur)

sensible heat recovery efficiency means, in respect of an energy-recovery ventilator or a heat-recovery ventilator, the ratio of the net sensible energy recovered by the unit’s supply airstream, as adjusted to account for the unit’s external and internal energy gains and losses, to the maximum sensible energy that would be recovered if the unit had an infinite transfer area. (efficacité de récupération de chaleur sensible)

Energy-recovery Ventilators

s. 277 — Energy-using product

An energy-recovery ventilator is prescribed as an energy-using product.

s. 277(2) — Limit

However, for the purposes of sections 4 and 5, an energy-recovery ventilator is not considered to be an energy-using product unless it is manufactured on or after January 1, 2020.

s. 278 — Information

For the purpose of subsection 5(1) of the Act, the following information must be collected in accordance with CSA C439-18 and be provided to the Minister in respect of an energy-recovery ventilator:

its maximum rated airflow at 0°C;

its sensible heat recovery efficiency at 0°C and the associated net supply airflow, expressed in L/s, and electrical power consumption, expressed in watts; and

unless the unit is marked for use only where the outdoor design temperature is greater than or equal to -10°C, its sensible heat recovery efficiency at -25°C and the associated net supply airflow, expressed in L/s.

Heat-recovery Ventilators

s. 279 — Energy-using product

A heat-recovery ventilator is prescribed as an energy-using product.

s. 279(2) — Limit

However, for the purposes of sections 4 and 5, a heat-recovery ventilator is not considered to be an energy-using product unless it is manufactured on or after January 1, 2020.

s. 280 — Information

For the purpose of subsection 5(1) of the Act, the following information must be collected in accordance with CSA C439-18 and be provided to the Minister in respect of a heat-recovery ventilator:

its maximum rated airflow at 0°C;

its sensible heat recovery efficiency at 0°C and the associated net supply airflow, expressed in L/s, and electrical power consumption, expressed in watts; and

unless the unit is marked for use only where the outdoor design temperature is greater than or equal to -10°C, its sensible heat recovery efficiency at -25°C and the associated net supply airflow, expressed in L/s.

Boilers

Interpretation

s. 314 — Definitions

The following definitions apply in this Division.

ASHRAE 103 means the ANSI/ASHRAE standard 103-2007 entitled Method of Testing for Annual Fuel Utilization Efficiency of Residential Central Furnaces and Boilers. (ASHRAE 103)

automatic water temperature adjustment device means a device that

adjusts the temperature of the water supplied by a boiler to ensure that an incremental change in inferred heat load produces a corresponding incremental change in the temperature of the water supplied or, if the boiler fires at a single input rate, automatically allows the burner or heating element to fire only when the device has determined that the inferred heat load cannot be met by the residual heat of the water in the system; and

when there is no inferred heat load, limits the water temperature in the boiler to not more than 60°C. (dispositif automatique de réglage de la température de l’eau)

CSA P.2 means the CSA standard CAN/CSA-P.2-13 entitled Testing Method for Measuring the Annual Fuel Utilization Efficiency of Residential Gas-Fired or Oil-Fired Furnaces and Boilers. (CSA P.2)

10 C.F.R. Appendix A means Appendix A to Subpart E, Part 431 of Title 10 to the United States Code of Federal Regulations, entitled Uniform Test Method for the Measurement of Thermal Efficiency and Combustion Efficiency of Commercial Packaged Boilers, as amended from time to time. (appendice A 10 C.F.R.)

Gas Boilers

s. 315 — Definitions

The following definitions apply in this Subdivision.

CGA P.2 means the CGA standard CGA P.2-1991 entitled Testing Method for Measuring Annual Fuel Utilization Efficiencies of Residential Furnaces and Boilers. (CGA P.2)

CSA P.2[Repealed, SOR/2019-164, s. 14]

gas boiler means a boiler that uses exclusively propane or natural gas, is intended for application in a low pressure steam, or hot water, central heating system and has an input rate of not more than 2 930.71 kW (10,000,000 Btu/h). (chaudière à gaz)

s. 315.1 — Type

For the purpose of these Regulations, a gas boiler is one of the following types:

household, if it has an input rate of less than 87.92 kW (300,000 Btu/h); or

commercial, if it is has an input rate of greater than or equal to 87.92 kW (300,000 Btu/h) but not more than 2 930.71 kW (10,000,000 Btu/h).

s. 316 — Energy-using product

A gas boiler is prescribed as an energy-using product.

s. 316(2) — Limits

However, a gas boiler is not considered to be an energy-using product

for the purpose of section 4 unless

it is a household gas boiler that is manufactured on or after June 30, 1999, or

it is a commercial gas boiler that is manufactured on or after January 1, 2025; and

for the purposes of sections 5 and 317 unless

it is a household gas boiler that is manufactured on or after December 31, 1998, or

it is a commercial gas boiler that is manufactured on or after January 1, 2025.

s. 317 — Energy efficiency standards — household

The energy efficiency standards set out in column 3 of Table 1 to this section apply to household gas boilers described in column 1 that are manufactured during the periods set out in column 4.

s. 317(2) — Testing standard — household

A household gas boiler complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by the standard set out in column 2 of Table 1 that are applicable to a gas boiler as defined in section 315.

s. 317(3) — Energy efficiency standards — commercial

The energy efficiency standards set out in column 2 of Table 2 to this section apply to commercial gas boilers described in column 1 that are manufactured on or after January 1, 2025.

s. 317(4) — Testing standard — commercial

A commercial gas boiler complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by 10 C.F.R. Appendix A that are applicable to a gas boiler as defined in section 315. TABLE 1 Item Column 1 Column 2 Column 3 Column 4 Energy-using Product Testing Standard Energy Efficiency Standard Period of Manufacture 1 Household gas boilers that are intended for low pressure steam systems CGA P.2 Annual fuel utilization efficiency ≥ 75%On or after December 31, 1998 and before September 1, 2010 2 Household gas boilers that are intended for low pressure steam systems CSA P.2 for annual fuel utilization efficiency On or after September 1, 2010 and before January 15, 2021 2.1 Household gas boilers that are intended for low pressure steam systems CSA P.2 for annual fuel utilization efficiency, standby power and off-mode power On or after January 15, 2021 3 Household gas boilers that are intended for hot water systems CGA P.2 Annual fuel utilization efficiency ≥ 80%On or after December 31, 1998 and before September 1, 2010 4 Household gas boilers that are intended for hot water systems CSA P.2 for annual fuel utilization efficiency On or after September 1, 2010 and before September 1, 2012 5 Household gas boilers that are intended for hot water systems and have tankless domestic water heating coils CSA P.2 for annual fuel utilization efficiency On or after September 1, 2012 and before July 1, 2023 5.1 Household gas boilers that are intended for hot water systems and have tankless domestic water heating coils CSA P.2 for annual fuel utilization efficiency, standby power and off-mode power On or after July 1, 2023 6 Household gas boilers that are intended for hot water systems and do not have tankless domestic water heating coils CSA P.2 for annual fuel utilization efficiency On or after September 1, 2012 and before July 1, 2023 7 Household gas boilers that are intended for hot water systems and do not have tankless domestic water heating coils CSA P.2 for annual fuel utilization efficiency, standby power and off-mode power On or after July 1, 2023 TABLE 2 Item Column 1 Column 2 Energy-using Product Energy Efficiency Standard 1 Commercial gas boilers that have an input rate of ≥ 87.92 kW (300,000 Btu/h) but ≤ 732.68 kW (2,500,000 Btu/h) and are intended for hot water systems Thermal efficiency ≥ 90%2 Commercial gas boilers that have an input rate of > 732.68 kW (2,500,000 Btu/h) but ≤ 2 930.71 kW (10,000,000 Btu/h) and are intended for hot water systems Combustion efficiency ≥ 90%3 Commercial gas boilers that have an input rate of ≥ 87.92 kW (300,000 Btu/h) but ≤ 732.68 kW (2,500,000 Btu/h) and are intended for low pressure steam systems Thermal efficiency ≥ 81%4 Commercial gas boilers that have an input rate of > 732.68 kW (2,500,000 Btu/h) but ≤ 2 930.71 kW (10,000,000 Btu/h) and are intended for low pressure steam systems Thermal efficiency ≥ 82%

s. 318 — Information

For the purpose of subsection 5(1) of the Act, the information set out in column 3 of the table to this section must be collected in accordance with the standard set out in column 2 and provided to the Minister in respect of a gas boiler described in column 1. TABLE Column 1 Column 2 Column 3 Item Energy-using Product Testing Standard Information 1 Household gas boilers manufactured on or after December 31, 1998 and before September 1, 2010 CGA P.2 2 Household gas boilers manufactured on or after September 1, 2010 and before January 15, 2021 and intended for low pressure steam systems CSA P.2 3 Household gas boilers manufactured on or after January 15, 2021 and intended for low pressure steam systems CSA P.2 4 Household gas boilers, other than those intended for low pressure steam systems, manufactured on or after September 1, 2010 and before July 1, 2023 CSA P.2 for information set out in paragraphs (a) to (c) 5 Household gas boilers, other than those intended for low pressure steam systems, manufactured on or after July 1, 2023 CSA P.2 for information set out in paragraphs (a) to (e) 6 Commercial gas boilers manufactured on or after January 1, 2025 10 C.F.R. Appendix A

Oil-Fired Boilers

s. 319 — Definitions

The following definitions apply in this Subdivision.

CSA B212 means the CSA standard CSA-B212-93 entitled Seasonal Energy Utilization Efficiencies of Oil-Fired Furnaces and Boilers. (CSA B212)

oil-fired boiler means a boiler that is intended for application in a low pressure steam, or hot water, central heating system, has an input rate of less than 2 930.71 kW (10,000,000 Btu/h) and is

exclusively oil-fired; or

capable of being fired, at the choice of the user, by either oil or another fuel. (chaudière à mazout)

s. 319.1 — Type

For the purpose of these Regulations, an oil-fired boiler is one of the following types:

household, if it has an input rate of less than 87.92 kW (300,000 Btu/h); or

commercial, if it is has an input rate of greater than or equal to 87.92 kW (300,000 Btu/h) but not more than 2 930.71 kW (10,000,000 Btu/h).

s. 320 — Energy-using product

An oil-fired boiler is prescribed as an energy-using product.

s. 320(2) — Limits

However, an oil-fired boiler is not considered to be an energy-using product

for the purpose of section 4, unless

it is a household oil-fired boiler that is manufactured on or after June 30, 1999, or

it is a commercial oil-fired boiler that is manufactured on or after January 1, 2025; and

for the purposes of sections 5 and 321, unless

it is a household oil-fired boiler that is manufactured on or after December 31, 1998, or

it is a commercial oil-fired boiler that is manufactured on or after January 1, 2025.

s. 321 — Energy efficiency standards — household

The energy efficiency standards set out in column 3 of Table 1 to this section apply to household oil-fired boilers described in column 1 that are manufactured during the periods set out in column 4.

s. 321(2) — Testing standard — household

A household oil-fired boiler complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by the standard set out in column 2 of Table 1 that are applicable to an oil-fired boiler as defined in section 319.

s. 321(3) — Energy-efficiency standards — commercial

The energy efficiency standards set out in column 2 of Table 2 to this section apply to commercial oil-fired boilers described in column 1 that are manufactured on or after January 1, 2025.

s. 321(4) — Testing Standard — commercial

A commercial oil-fired boiler complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by 10 C.F.R. Appendix A that are applicable to an oil-fired boiler as defined in section 319. TABLE 1 Item Column 1 Column 2 Column 3 Column 4 Energy-using Product Testing Standard Energy Efficiency Standard Period of Manufacture 1 Household oil-fired boilers CSA B212 Seasonal energy utilization efficiency ≥ 80%On or after December 31, 1998 and before September 1, 2010 2 Household oil-fired boilers that are intended for low pressure steam systems ASHRAE 103 Annual fuel utilization efficiency ≥ 82%On or after September 1, 2010 and before January 15, 2021 2.1 Household oil-fired boilers that are intended for low pressure steam systems CSA P.2 for annual fuel utilization efficiency, standby power and off-mode power On or after January 15, 2021 3 Household oil-fired boilers that are intended for hot water systems ASHRAE 103 Annual fuel utilization efficiency ≥ 84%On or after September 1, 2010 and before September 1, 2012 4 Household oil-fired boilers that are intended for hot water systems and have tankless domestic water heating coils ASHRAE 103 Annual fuel utilization efficiency ≥ 84%On or after September 1, 2012 and before January 15, 2021 4.1 Household oil-fired boilers that are intended for hot water systems and have tankless domestic water heating coils CSA P.2 for annual fuel utilization efficiency, standby power and off-mode power On or after January 15, 2021 5 Household oil-fired boilers that are intended for hot water systems and do not have tankless domestic water heating coils ASHRAE 103 for annual fuel utilization efficiency On or after September 1, 2012 and before January 15, 2021 6 Household oil-fired boilers that are intended for hot water systems and do not have tankless domestic water heating coils CSA P.2 for annual fuel utilization efficiency, standby power and off-mode power On or after January 15, 2021 TABLE 2 Item Column 1 Column 2 Energy-using Product Energy Efficiency Standard 1 Commercial oil-fired boilers that have an input rate of ≥ 87.92 kW (300,000 Btu/h) but ≤ 732.68 kW (2,500,000 Btu/h) and are intended for hot water systems Thermal efficiency ≥ 87%2 Commercial oil-fired boilers that have an input rate of > 732.68 kW (2,500,000 Btu/h) but ≤ 2 930.71 kW (10,000,000 Btu/h) and are intended for hot water systems Combustion efficiency ≥ 88%3 Commercial oil-fired boilers that have an input rate of ≥ 87.92 kW (300,000 Btu/h) but ≤ 732.68 kW (2,500,000 Btu/h) and are intended for low pressure steam systems Thermal efficiency ≥ 84%4 Commercial oil-fired boilers that have an input rate of > 732.68 kW (2,500,000 Btu/h) but ≤ 2 930.71 kW (10,000,000 Btu/h) and are intended for low pressure steam systems Thermal efficiency ≥ 85%

s. 322 — Information

For the purpose of subsection 5(1) of the Act, the information set out in column 3 of the table to this section must be collected in accordance with the standard set out in column 2 and provided to the Minister in respect of an oil-fired boiler described in column 1. TABLE Column 1 Column 2 Column 3 Item Energy-using Product Testing Standard Information 1 Household oil-fired boilers manufactured on or after December 31, 1998 and before September 1, 2010 CSA B212 2 Household oil-fired boilers manufactured on or after September 1, 2010 and before January 15, 2021 ASHRAE 103 for information set out in paragraphs (a) to (f) 3 Household oil-fired boilers manufactured on or after January 15, 2021 CSA P.2 for information set out in paragraphs (a) to (e) 4 Commercial oil-fired boilers manufactured on or after January 1, 2025 10 C.F.R. Appendix A

Electric Boilers

s. 323 — Definition of electric boiler

In this Subdivision, electric boiler means a boiler that uses electric energy as a source of heat, is intended for application in a hot water central heating system, has an input rate of less than 88 kW (300,000 Btu/h) and is not equipped with tankless domestic water heating coils.

s. 324 — Energy-using product

An electric boiler is prescribed as an energy-using product.

s. 324(2) — Limit

However, for the purposes of sections 4, 5 and 325, an electric boiler is not considered to be an energy-using product unless it is manufactured on or after September 1, 2012.

s. 325 — Energy efficiency standard

The energy efficiency standard that applies to an electric boiler is that it must be equipped with an automatic water temperature adjustment device without which the boiler is not operable.

s. 326 — Information

For the purpose of subsection 5(1) of the Act, the following information must be provided to the Minister in respect of an electric boiler:

its input rate, expressed in kilowatts, collected in accordance with ASHRAE 103; and

the type of automatic water temperature adjustment device that it has.

Water Heaters

Interpretation

s. 369 — Definitions

The following definitions apply in this Division.

CSA P.3-15 means the CSA standard CAN/CSA-P.3-15 entitled Testing method for measuring energy consumption and determining efficiencies of gas-fired and fuel oil-fired water heaters. (CSA P.3-15)

electric water heater means a stationary electric storage tank water heater that is intended for use on a pressurized water system and has a V r of at least 50 L (13.21 US gallons). (chauffe-eau électrique)

first-hour rating means, in respect of an electric water heater, gas-fired storage water heater or oil-fired water heater, the measure of the maximum volume of hot water that the water heater can supply within an hour that begins when the water in the water heater is fully heated. (capacité de première heure)

gas-fired instantaneous water heater means a flow-activated water heater that uses propane or natural gas for fuel, has a V r that is less than or equal to 38 L (10 US gallons) and has an input rate to V r ratio of at least 309 W/L (4,000 Btu/h/US gallon). (chauffe-eau instantané au gaz)

gas-fired storage water heater means a stationary gas-heated water container that uses propane or natural gas for fuel and has a V r of at least 76 L (20 US gallons). (chauffe-eau à réservoir alimenté au gaz)

oil-fired water heater means a water heater that uses oil for fuel and has a V r of at least 76 L (20 US gallons). (chauffe-eau à mazout)

10 C.F.R. Appendix A means Appendix A to Subpart G, Part 431 of Title 10 to the United States Code of Federal Regulations, entitled Uniform Test Method for the Measurement of Thermal Efficiency and Standby Loss of Gas-Fired and Oil-Fired Storage Water Heaters and Storage-Type Instantaneous Water Heaters, as amended from time to time. (appendice A 10 C.F.R.)

10 C.F.R. Appendix E means Appendix E to Subpart B, Part 430 of Title 10 to the United States Code of Federal Regulations, entitled Uniform Test Method for Measuring the Energy Consumption of Water Heaters, as amended from time to time, except for sections 5.1.1 and 5.1.2. (appendice E 10 C.F.R.)

V eff means the effective storage volume, expressed in litres, of a water heater’s storage tank, as determined in accordance with 10 C.F.R. Appendix E. (V eff)

V r means the nominal volume, expressed in litres, of a water heater’s storage tank. (V r)

V s means the measured storage volume, expressed in litres, of a water heater’s storage tank. (V s)

s. 369(2) — Interpretation — draw pattern

In this Division, a reference to

a “very-small-usage” draw pattern is to be read as a reference to the draw pattern set out in Table III.1 to section 5.5 of 10 C.F.R. Appendix E;

a “low-usage” draw pattern is to be read as a reference to the draw pattern set out in Table III.2 to section 5.5 of 10 C.F.R. Appendix E;

a “medium-usage” draw pattern is to be read as a reference to the draw pattern set out in Table III.3 to section 5.5 of 10 C.F.R. Appendix E; and

a “high-usage” draw pattern is to be read as a reference to the draw pattern set out in Table III.4 to section 5.5 of 10 C.F.R. Appendix E.

Electric Water Heaters

s. 370 — Definitions

The following definitions apply in this Subdivision.

bottom inlet means a cold water inlet, other than one with a dip tube, that enters near the bottom of the water heater’s storage tank. (entrée inférieure)

CSA C191-04 means the CSA standard CAN/CSA-C191-04 entitled Performance of Electric Storage Tank Water Heaters for Domestic Hot Water Service. (CSA C191-04)

electric water heater[Repealed, SOR/2025-110, s. 46]

10 C.F.R. Appendix B means Appendix B to Subpart G, Part 431 of Title 10 to the United States Code of Federal Regulations, entitled Uniform Test Method for the Measurement of Standby Loss of Electric Storage Water Heaters and Storage-Type Instantaneous Water Heaters, as amended from time to time. (appendice B 10 C.F.R.)

s. 370.1 — Type

For the purpose of these Regulations, an electric water heater is one of the following types:

household, if it has an input rate of less than or equal to 12 kW (40,982 Btu/h); or

commercial, if it is has an input rate of greater than 12 kW (40,982 Btu/h).

s. 371 — Energy-using product

An electric water heater is prescribed as an energy-using product.

s. 371(2) — Limits

However, an electric water heater is not considered to be an energy-using product

for the purposes of sections 4 and 5, unless it is

a household electric water heater that is manufactured on or after February 3, 1995, or

a commercial electric water heater that is manufactured on or after January 1, 2020; and

for the purposes of section 372, unless it is

a household electric water heater that is manufactured on or after February 3, 1995,

a commercial electric water heater that is manufactured on or after January 1, 2020, or

a commercial electric water heater with a V r that is less than or equal to 530 L (140 US gallons).

s. 372 — Energy efficiency standards

The energy efficiency standards set out in column 3 of the table to this section apply to an electric water heater described in column 1 that is manufactured during the periods set out in column 4.

s. 372(2) — Testing standard

An electric water heater described in column 1 complies with the energy efficiency standard set out in column 3 if it meets that standard when tested in accordance with testing procedures established by the standard set out in column 2 that are applicable to an electric water heater as defined in subsection 369(1). TABLE Item Column 1 Column 2 Column 3 Column 4 Energy-using Product Testing Standard Energy Efficiency Standard Period of Manufacture 1 Household electric water heaters that have a bottom inlet and a V r of ≥ 50 L (13.2 US gallons) but ≤ 270 L (71.3 US gallons) CSA C191-04 Standby loss, in W, ≤ 40 + 0.2 V r On or after February 3, 1995 and before May 6, 2029 2 Household electric water heaters that have a bottom inlet and a V r of ≥ 50 L (13.2 US gallons) but < 76 L (20 US gallons) CSA C191-04 Standby loss, in W, ≤ 40 + 0.2 V r On or after May 6, 2029 3 Household electric water heaters that have a bottom inlet and a V r of > 270 L (71.3 US gallons) but ≤ 454 L (120 US gallons) CSA C191-04 Standby loss, in W, ≤ 0.472 V r − 33.5 On or after February 3, 1995 and before May 6, 2029 4 Household electric water heaters that have a top inlet and a V r of ≥ 50 L (13.2 US gallons) but ≤ 270 L (71.3 US gallons) CSA C191-04 Standby loss, in W, ≤ 35 + 0.2 V r On or after February 3, 1995 and before May 6, 2029 5 Household electric water heaters that have a top inlet and a V r of ≥ 50 L (13.2 US gallons) but < 76 L (20 US gallons) CSA C191-04 Standby loss, in W, ≤ 35 + 0.2 V r On or after May 6, 2029 6 Household electric water heaters that have a top inlet and a V r of > 270 L (71.3 US gallons) but ≤ 454 L (120 US gallons) CSA C191-04 Standby loss, in W, ≤ 0.472 V r − 38.5 On or after February 3, 1995 and before May 6, 2029 7 Household electric water heaters that have a V eff of ≥ 76 L (20 US gallons) but ≤ 208 L (55 US gallons) 10 C.F.R. Appendix E On or after May 6, 2029 8 Household electric water heaters that have a V eff of ˃ 208 L (55 US gallons) but ≤ 454 L (120 US gallons) 10 C.F.R. Appendix E Uniform energy factor ≥ 0.9349 − 0.000026 V eff On or after May 6, 2029 9 Commercial electric water heaters 10 C.F.R. Appendix B Standby loss, in %/hr ≤ 0.3 + 102.2/V s On or after January 1, 2020

s. 373 — Information

For the purpose of subsection 5(1) of the Act, the information set out in column 3 of the table to this section must be collected in accordance with the standard set out in column 2 and provided to the Minister in respect of an electric water heater described in column 1. TABLE Column 1 Column 2 Column 3 Item Energy-using Product Testing Standard Information 1 Household electric water heaters manufactured on or after February 3, 1995 and before May 6, 2029 CSA C191-04 for information set out in paragraphs (a) to (c) 1.1 Household electric water heaters with a V r of ≥ 50 L (13.2 US gallons) but < 76 L (20 US gallons), manufactured on or after May 6, 2029 CSA C191-04 for information set out in paragraphs (a) to (c) 1.2 Household electric water heaters with a V r ≥ 76 L (20 US gallons) but ≤ 454 L (120 US gallons), manufactured on or after May 6, 2029 10 C.F.R. Appendix E 2 Commercial electric water heaters with a V r ≤ to 530 L (140 US gallons), manufactured on or after January 1, 2020 10 C.F.R. Appendix B 3 Commercial electric water heaters with a V r > 530 L (140 US gallons), manufactured on or after January 1, 2020 10 C.F.R. Appendix B

s. 373.1 — Early compliance

An electric water heater that is manufactured on or after May 6, 2028 and before May 6, 2029 is deemed to satisfy the requirements of sections 372 and 373 if it satisfies the requirements of those sections that would have applied to the electric water heater if it had been manufactured on or after May 6, 2029.

Gas-Fired Storage Water Heaters

s. 374 — Definitions

The following definitions apply in this Subdivision.

CSA P.3-04 means the CSA standard CAN/CSA-P.3-04 entitled Testing Method for Measuring Energy Consumption and Determining Efficiencies of Gas-Fired Storage Water Heaters. (CSA P.3-04)

gas-fired storage water heater[Repealed, SOR/2025-110, s. 50]

replacement unit means a commercial gas-fired storage water heater that is marked for replacement installations only. (unité de remplacement)

s. 374.1 — Type

For the purpose of these Regulations, a gas-fired storage water heater is one of the following types:

household, if it has an input rate of less than or equal to 21.97 kW (75,000 Btu/h); or

commercial, if it is has an input rate of greater than 21.97 kW (75,000 Btu/h).

s. 375 — Energy-using product

A gas-fired storage water heater is prescribed as an energy-using product.

s. 375(2) — Limits

However, for the purposes of sections 4, 5 and 376, a gas-fired storage water heater is not considered to be an energy-using product unless

it is a household gas-fired storage water heater that is manufactured on or after February 3, 1995; or

it is a commercial gas-fired storage water heater that is manufactured on or after July 1, 2023.

s. 376 — Energy-efficiency standards — household

The energy efficiency standards set out in column 3 of Table 1 to this section apply to household gas-fired storage water heaters described in column 1 that are manufactured during the periods set out in column 4.

s. 376(2) — Testing standard — household

A household gas-fired storage water heater complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by the standard set out in column 2 of Table 1 that are applicable to a gas-fired storage water heater as defined in subsection 369(1).

s. 376(3) — Energy efficiency standards — commercial

The energy efficiency standards set out in column 3 of Table 2 to this section apply to commercial gas-fired storage water heaters described in column 1 that are manufactured on or after July 1, 2023.

s. 376(4) — Testing standard — commercial

A commercial gas-fired storage water heater complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by the standard set out in column 2 of Table 2 that are applicable to a gas-fired storage water heater as defined in subsection 369(1). TABLE 1 Column 1 Column 2 Column 3 Column 4 Item Energy-using Product Testing Standard Energy Efficiency Standard Period of Manufacture 1 Household gas-fired storage water heaters CSA P.3-04 Energy factor of ≥ 0.67 – 0.0005 V r On or after February 3, 1995 and before December 31, 2016 2 Household gas-fired storage water heaters CSA P.3-04 Energy factor of ≥ 0.675 – 0.00039 V r On or after December 31, 2016 and before January 1, 2018 3 Household gas-fired storage water heaters that have a first-hour rating of < 68 L (18 US gallons) On or after January 1, 2018 and before May 6, 2029 4 Household gas-fired storage water heaters that have a first-hour rating of ≥ 68 L (18 US gallons) but < 193 L (51 US gallons) On or after January 1, 2018 and before May 6, 2029 5 Household gas-fired storage water heaters that have a first-hour rating of ≥ 193 L (51 US gallons) but < 284 L (75 US gallons) On or after January 1, 2018 and before May 6, 2029 6 Household gas-fired storage water heaters that have a first-hour rating of ≥ 284 L (75 US gallons) On or after January 1, 2018 and before May 6, 2029 7 Household gas-fired storage water heaters 10 C.F.R. Appendix E On or after May 6, 2029 TABLE 2 Column 1 Column 2 Column 3 Item Energy-using Product Testing Standard Energy Efficiency Standard 1 Commercial gas-fired storage water heaters, other than replacement units, that have an input rate of > 21.97 kW (75,000 Btu/h) but ≤ 30.5 kW (105,000 Btu/h), have a V r of ≤ 454 L (120 US gallons), use single-phase power and limit water temperatures to < 82°C (180°F) CSA P.3-15 Uniform energy factor ≥ 0.8107-0.00021 V s 2 Commercial gas-fired storage water heaters that are replacement units, have an input rate of > 21.97 kW (75,000 Btu/h) but ≤ 30.5 kW (105,000 Btu/h), have a V r of ≤ 454 L (120 US gallons), use single-phase power and limit water temperatures to < 82°C (180°F) CSA P.3-15 Uniform energy factor ≥ 0.6597-0.00024 V s 3 Commercial gas-fired storage water heaters, other than replacement units, that have a V r of > 530 L (140 US gallons) 10 C.F.R. Appendix A Thermal efficiency ≥ 90%4 Commercial gas-fired storage water heaters that are replacement units and that have a V r of > 530 L (140 US gallons) 10 C.F.R. Appendix A Thermal efficiency ≥ 80%5 Commercial gas-fired storage water heaters, other than those described in items 1 and 3, that are not replacement units 10 C.F.R. Appendix A 6 Commercial gas-fired storage water heaters, other than those described in items 2 and 4, that are replacement units 10 C.F.R. Appendix A

For the purpose of subsection 5(1) of the Act, the information set out in column 3 of the table to this section must be collected in accordance with the standard set out in column 2 and provided to the Minister in respect of a gas-fired storage water heater described in column 1. TABLE Column 1 Column 2 Column 3 Item Energy-using Product Testing Standard Information 1 Household gas-fired storage water heaters that are manufactured on or after February 3, 1995 and before January 1, 2018 CSA P.3-04 2 Household gas-fired storage water heaters that are manufactured on or after January 1, 2018 and before May 6, 2029 2.1 Household gas-fired storage water heaters that are manufactured on or after May 6, 2029 10 C.F.R. Appendix E 3 Commercial gas-fired storage water heaters that have an input rate of > 21.97 kW (75,000 Btu/h) but ≤ 30.5 kW (105,000 Btu/h), have a V r of ≤ 454 L (120 US gallons), use single-phase power, limit water temperatures to < 82°C (180°F) and are manufactured on or after July 1, 2023 CSA P.3-15 4 Commercial gas-fired storage water heaters with a V r of > 530 L (140 US gallons) that are manufactured on or after July 1, 2023 10 C.F.R. Appendix A 5 Commercial gas-fired storage water heaters, other than those described in items 3 and 4, that are manufactured on or after July 1, 2023 10 C.F.R. Appendix A

Oil-Fired Water Heaters

s. 378 — Definitions

The following definitions apply in this Subdivision.

CSA B211-00 means the CSA standard CAN/CSA-B211-00 entitled Energy Efficiency of Oil-Fired Storage Tank Water Heaters. (CSA B211-00)

oil-fired water heater[Repealed, SOR/2025-110, s. 53]

s. 378.1 — Type

For the purpose of these Regulations, an oil-fired water heater is one of the following types:

household, if it has an input rate of less than or equal to 30.5 kW (105,000 Btu/h); or

commercial, if it is has an input rate of greater than 30.5 kW (105,000 Btu/h).

s. 379 — Energy-using product

An oil-fired water heater is prescribed as an energy-using product.

s. 379(2) — Limits

However, for the purposes of sections 4, 5 and 380, an oil-fired water heater is not considered to be an energy-using product unless

it is a household oil-fired water heater that is manufactured on or after February 3, 1995; or

it is a commercial oil-fired water heater that is manufactured on or after January 1, 2020.

s. 380 — Energy efficiency standards — household

The energy efficiency standards set out in column 3 of Table 1 to this section apply to household oil-fired water heaters described in column 1 that are manufactured during the period set out in column 4.

s. 380(2) — Testing standard — household

A household oil-fired water heater complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by the standard set out in column 2 of Table 1 that are applicable to an oil-fired water heater as defined in subsection 369(1).

s. 380(3) — Energy efficiency standards — commercial

The energy efficiency standards set out in column 2 of Table 2 to this section apply to commercial oil-fired water heaters described in column 1 that are manufactured on or after January 1, 2020.

s. 380(4) — Testing standard — commercial

A commercial oil-fired water heater complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by the standard set out in column 2 of Table 2 that are applicable to an oil-fired water heater as defined in subsection 369(1). TABLE 1 Column 1 Column 2 Column 3 Column 4 Item Energy-using Product Testing Standard Energy Efficiency Standard Period of Manufacture 1 Household oil-fired water heaters CSA B211-00 Energy factor of ≥ 0.59 – 0.0005 V r On or after February 3, 1995 and before December 31, 2016 2 Household oil-fired water heaters CSA B211-00 Energy factor of ≥ 0.68 – 0.0005 V r On or after December 31, 2016 and before January 1, 2018 3 Household oil-fired water heaters that have a first-hour rating of < 68 L (18 US gallons) On or after January 1, 2018 and before May 6, 2029 4 Household oil-fired water heaters that have a first-hour rating of ≥ 68 L (18 US gallons) but < 193 L (51 US gallons) On or after January 1, 2018 and before May 6, 2029 5 Household oil-fired water heaters that have a first-hour rating of ≥ 193 L (51 US gallons) but < 284 L (75 US gallons) On or after January 1, 2018 and before May 6, 2029 6 Household oil-fired water heaters that have a first-hour rating of ≥ 284 L (75 US gallons) On or after January 1, 2018 and before May 6, 2029 7 Household oil-fired water heaters 10 C.F.R. Appendix E On or after May 6, 2029 TABLE 2 Column 1 Column 2 Column 3 Item Energy-using Product Testing Standard Energy Efficiency Standard 1 Commercial oil-fired water heaters that have an input rate of > 30.5 kW (105,000 Btu/h) but ≤ 40.99 kW (140,000 Btu/h), have a V r of ≤ 454 L (120 US gallons), use single-phase power, limit water temperatures to < 82°C (180°F) and are manufactured on or after January 1, 2020 CSA P.3-15 Uniform energy factor ≥ 0.6740 - 0.00035 V s 2 Commercial oil-fired water heaters with a V r of > 530 L (140 US gallons) that are manufactured on or after January 1, 2020 10 C.F.R. Appendix A Thermal efficiency ≥ 80%3 Commercial oil-fired water heaters, other than those described in items 1 and 2, that are manufactured on or after January 1, 2020 10 C.F.R. Appendix A

s. 381 — Information

For the purpose of subsection 5(1) of the Act, the information set out in column 3 of the table to this section must be collected in accordance with the standard set out in column 2 and provided to the Minister in respect of an oil-fired water heater described in column 1. TABLE Item Column 1 Column 2 Column 3 Energy-using Product Testing Standard Information 1 Household oil-fired water heaters that are manufactured on or after February 3, 1995 and before January 1, 2018 CSA B211-00 2 Household oil-fired water heaters that are manufactured on or after January 1, 2018 and before May 6, 2029 2.1 Household oil-fired water heaters that are manufactured on or after May 6, 2029 10 C.F.R. Appendix E 3 Commercial oil-fired water heaters that have an input rate of > 30.5 kW (105,000 Btu/h) but ≤ 40.99 kW (140,000 Btu/h), have a V r of ≤ 454 L (120 US gallons), use single-phase power, limit water temperatures to < 82°C (180°F) and are manufactured on or after January 1, 2020 CSA P.3-15 4 Commercial oil-fired water heaters with a V r of > 530 L (140 US gallons) that are manufactured on or after January 1, 2020 10 C.F.R. Appendix A 5 Commercial oil-fired water heaters, other than those described in items 3 and 4, that are manufactured on or after January 1, 2020 10 C.F.R. Appendix A

Gas-Fired Instantaneous Water Heaters

s. 382 — Definitions

The following definitions apply in this Subdivision.

gas-fired instantaneous water heater[Repealed, SOR/2025-110, s. 56]

maximum flow rate means, in respect of a gas-fired instantaneous water heater, the maximum litres per minute (gallons per minute) of hot water that can be supplied by the water heater while operating in a steady state and maintaining a nominal temperature rise of 37.3°C (67°F). (débit maximal)

10 C.F.R. Appendix C means Appendix C to the Subpart G, Part 431 of Title 10 to the United States Code of Federal Regulations, entitled Uniform Test Method for the Measurement of Thermal Efficiency and Standby Loss of Gas-Fired and Oil-Fired Instantaneous Water Heaters and Hot Water Supply Boilers (Other Than Storage-Type Instantaneous Water Heaters), as amended from time to time. (appendice C 10 C.F.R.)

s. 383 — Type

For the purpose of these Regulations, a gas-fired instantaneous water heater is one of the following types:

household, if it has an input rate of less than 58.56 kW (200,000 Btu/h), has a V r of no greater than 7.6 L (2 US gallons) and is designed to provide hot water at a temperature no greater than 82°C (180°F); or

commercial, if it is not described in paragraph (a).

s. 384 — Energy-using product

A gas-fired instantaneous water heater is prescribed as an energy-using product.

s. 384(2) — Limit

However, for the purposes of sections 4, 5 and 385, a gas-fired instantaneous water heater is not considered to be an energy-using product unless

it is a household gas-fired instantaneous water heater that is manufactured on or after January 1, 2020; or

it is a commercial gas-fired instantaneous water heater that is manufactured on or after July 1, 2023.

s. 385 — Energy efficiency standards

The energy efficiency standards set out in column 3 of the table to this section apply to gas-fired instantaneous water heaters described in column 1 that are manufactured during the period set out in column 4.

s. 385(2) — Testing standards

A gas-fired instantaneous water heater complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by the standard set out in column 2 that are applicable to a gas-fired instantaneous water heater as defined in subsection 369(1). TABLE Item Column 1 Column 2 Column 3 Column 4 Energy-using Product Testing Standard Energy Efficiency Standard Manufacturing Period 1 Household gas-fired instantaneous water heaters that have a maximum flow rate of < 6.4 L/min CSA P.3-15 Uniform energy factor ≥ 0.86 On or after January 1, 2020 and before May 6, 2029 2 Household gas-fired instantaneous water heaters that have a maximum flow rate of ≥ 6.4 L/min CSA P.3-15 Uniform energy factor ≥ 0.87 On or after January 1, 2020 and before May 6, 2029 3 Household gas-fired instantaneous water heaters that have a maximum flow rate of < 6.4 L/min 10 C.F.R. Appendix E Uniform energy factor ≥ 0.86 On or after May 6, 2029 4 Household gas-fired instantaneous water heaters that have a maximum flow rate of ≥ 6.4 L/min 10 C.F.R. Appendix E Uniform energy factor ≥ 0.87 On or after May 6, 2029 5 Commercial gas-fired instantaneous water heaters 10 C.F.R. Appendix C Thermal efficiency ≥ 94%On or after July 1, 2023

s. 386 — Information

For the purpose of subsection 5(1) of the Act, the information set out in column 3 of the table to this section must be collected in accordance with the standard set out in column 2 and provided to the Minister in respect of a gas-fired instantaneous water heater described in column 1. TABLE Item Column 1 Column 2 Column 3 Energy-using Product Testing Standard Information 1 Household gas-fired instantaneous water heaters manufactured on or after January 1, 2020 and before May 6, 2029 CSA P.3-15 1.1 Household gas-fired instantaneous water heaters manufactured on or after May 6, 2029 10 C.F.R. Appendix E 2 Commercial gas-fired instantaneous water heaters manufactured on or after July 1, 2023 10 C.F.R. Appendix C

Lamps and Lamp Ballasts

Interpretation

s. 424 — Definitions

The following definitions apply in this Division.

ANSI C78.20[Repealed, SOR/2025-110, s. 60]

ANSI C78.79 means the ANSI standard ANSI C78.79-2014 entitled American National Standard for Electric Lamps — Nomenclature for Envelope Shapes Intended for Use with Electric Lamps. (ANSI C78.79)

ANSI C79.1[Repealed, SOR/2018-201, s. 42]

ANSI C81.61 means the ANSI standard ANSI C81.61-2016 entitled American National Standard for Electrical Lamp Bases — Specifications for Bases (Caps) for Electric Lamps. (ANSI C81.61)

appliance lamp[Repealed, SOR/2025-110, s. 60]

CIE 13.3 means the CIE standard CIE 013.3-1995 entitled Method of Measuring and Specifying Colour Rendering Properties of Light Sources. (CIE 13.3)

CIE 15 means the CIE standard CIE 015:2004 entitled Colorimetry. (CIE 15)

coloured lamp[Repealed, SOR/2025-110, s. 60]

colour rendering index means the measured degree of colour shift that objects undergo when they are illuminated by a light source as compared with the colour of those same objects when they are illuminated by a reference source of comparable colour temperature. (indice de rendu des couleurs)

former Regulations means these Regulations as they read immediately before the day on which subsection 1(2) of the Regulations Amending the Energy Efficiency Regulations, 2016 (Amendment 18) comes into force. (règlement antérieur)

IES Handbook means the IES publication entitled Lighting Handbook, 9th edition. (Manuel IES)

IES LM16 means the IES standard IES LM-16-1993 entitled Practical Guide to Colorimetry of Light Sources. (IES LM16)

IES LM45[Repealed, SOR/2025-110, s. 60]

IES LM49[Repealed, SOR/2025-110, s. 60]

IES LM65[Repealed, SOR/2025-110, s. 60]

incandescent reflector lamp[Repealed, SOR/2025-110, s. 60]

infrared lamp[Repealed, SOR/2025-110, s. 60]

lamp efficacy means the number of lumens per watt determined by

dividing a lamp’s luminous flux by its power, measured under equilibrium conditions at the time of determining the luminous flux; and

in the case of a general service incandescent reflector lamp, rounding the number calculated under paragraph (a) to the nearest half number. (efficacité lumineuse)

modified spectrum lamp[Repealed, SOR/2025-110, s. 60]

plant lamp means a lamp that is designed and marketed for plant growing applications and that emits its highest radiant power peaks in the range of 440 to 490 nm, 620 to 740 nm or both of these ranges of the electromagnetic spectrum. (lampe pour horticulture)

rough service lamp[Repealed, SOR/2025-110, s. 60]

shatter-resistant lamp[Repealed, SOR/2025-110, s. 60]

silver bowl lamp[Repealed, SOR/2025-110, s. 60]

submersible lamp[Repealed, SOR/2025-110, s. 60]

vibration service lamp[Repealed, SOR/2025-110, s. 60]

Labelling

s. 425 — Label required

Every general service lamp that is manufactured on or after January 1, 2027 and that, for the purpose of sale or lease, is shipped from one province to another or imported into Canada must be labelled in accordance with sections 426 to 429.

s. 425(2) — Former Regulations

Sections 425 to 429 of the former Regulations continue to apply in respect of a lamp that is referred to in section 425 of the former Regulations that is manufactured before January 1, 2027.

s. 426 — Information on principal display panel

The principal display panel of the product’s package must display the following information in the following order:

the words “Light output” and “Flux lumineux”, followed by the numerical value of the product’s luminous flux and the word “lumens”;

the words “Efficacy” and “Efficacité”, followed by the numerical value of the product’s nominal efficacy and the words “lumens/watt”;

the words “Power” and “Puissance”, followed by the numerical value of the product’s nominal power consumption and the word “watts”;

the words “Life” and “Durée de vie”, followed by the numerical value of the product’s life and the words “hours” and “heures”, respectively; and

the words “Light appearance” and “Apparence de la lumière”, followed by the numerical value of the product’s correlated colour temperature and the upper case letter “K” or the word “Kelvin”.

s. 426(2) — Font and size

The words “Light output”, “Flux lumineux”, “Efficacy”, “Efficacité”, “Power”, “Puissance”, “Life”, “Durée de vie”, “Light appearance” and “Apparence de la lumière” must be in the same font and be equal in size.

s. 426(3) — Font and size — units

The words “lumens”, “lumens/watt”, “watts”, “hours”, “heures” and “Kelvin” and the upper case letter “K” must be in the same font and be equal in size, but they must not be more than 50% of the size of the words referred to in subsection (2).

s. 426(4) — Font and size — numerical values

The numerical values indicating the product’s luminous flux, efficacy, nominal power, life and correlated colour temperature must be in the same font and be equal in size.

s. 426(5) — Three-way lamps

If the product is a three-way lamp, the information required by paragraphs (1)(a) to (c) must be displayed for each level of the lamp’s operation.

s. 426(6) — Variable correlated colour temperature

If the product has a variable correlated colour temperature, the information required by paragraph (1)(e) must be displayed for the lamp’s range of operation or for each level of its operation.

s. 427 — Model number

The lamp model number must be indicated on both the product packaging and the lamp itself.

s. 428 — Design voltage other than 120 V

If the design voltage of the product is other than 120 V, the information required by section 426 may correspond to

a voltage of 120 V, followed by the words “at 120 volts” and “à 120 volts”; or

the design voltage, followed by the words, “at [design voltage] volts” and “à [tension spécifique]”.

s. 428(2) — Additional information

If the information corresponds to the design voltage,

the following statements must be displayed on the principal display panel:

“This product is designed for [design voltage] volts. When used on the normal line voltage of 120 volts, the light output and energy efficiency are noticeably reduced. See [appropriate panel] panel for 120-volt rating.”

« Ce produit a été conçu en fonction d’une tension de [tension spécifique] volts. S’il est employé à la tension normale de 120 volts, son flux lumineux et son efficacité énergétique s’en trouveront considérablement réduits. Voir le panneau [panneau en cause] pour les renseignements correspondant à une tension de 120 volts. »;

the information required by section 426 for the product corresponding to a voltage of 120 V, followed by the words “at 120 volts” and “à 120 volts”, must be displayed on a panel of the product’s package other than the principal display panel; and

the design voltage must be displayed on every panel that displays the information required by section 426, other than the panel on which the information required by paragraph (b) is displayed.

s. 429 — Multiple lamps in common package

If more than one type of lamp is included in a common package and their characteristics are not uniform, the principal display panel of the common package must display the following information for each type of lamp:

its design voltage; and

the information required by section 426, which must be in the size and font specified in that section.

[Repealed, SOR/2025-110, s. 64]

[Repealed]

[Repealed]

[Repealed]

General Service Lamps

s. 433 — Definitions

The following definitions apply in this Subdivision.

10 C.F.R. §430.23(gg) means paragraph 430.23(gg) of Subpart B, Part 430 of Title 10 to the United States Code of Federal Regulations, as amended from time to time. (10 C.F.R. §430.23(gg))

appliance lamp means a lamp that

is designed and marketed to operate in a household appliance such as a refrigerator, oven or vacuum cleaner; and

has a maximum wattage of 40 W. (lampe pour appareil domestique)

black light lamp means an ultraviolet lamp that has its highest radiant power peaks in the UV-A band (315 to 400 nm) of the electromagnetic spectrum. (lampe à lumière noire)

bug lamp means a lamp that has radiant power peaks above 550 nm on the electromagnetic spectrum and a visible yellow coating. (lampe anti-insectes)

CFL means a compact fluorescent lamp that has an integrated or non-integrated single base. It does not include circline or U-shaped lamps. (LFC)

coloured lamp means a lamp that is designed and marketed as a coloured lamp and that, in each of its modes of operation, has,

if it is an incandescent lamp,

a colour rendering index of less than 50, as determined in accordance with CIE 13.3, or

a correlated colour temperature of less than 2500 K or greater than 4600 K; and

if it is a lamp other than an incandescent lamp,

a colour rendering index of less than 40, as determined in accordance with CIE 13.3, or

a correlated colour temperature of less than 2500 K or greater than 7000 K. (lampe colorée)

fluorescent lamp means a low-pressure mercury, electric-discharge source in which a fluorescing coating transforms some of the ultraviolet energy generated by the mercury discharge into light. (lampe fluorescente)

general lighting application means lighting that provides an interior or exterior area with overall illumination. (source d’éclairage général)

general service incandescent lamp means a standard incandescent lamp, including a halogen type lamp, that is intended for general lighting applications and that

has a medium screw base;

has a lumen range of not less than 310 lm and not more than 2600 lm or, in the case of a modified spectrum incandescent lamp, not less than 232 lm and not more than 1950 lm; and

is capable of being operated at a voltage that is at least partially within the range from 110 V to 130 V.

It does not include an appliance lamp, black light lamp, bug lamp, coloured lamp, G-shape lamp — as described in ANSI C78.79 — with a diameter of 127 mm (5 in) or more, infrared lamp, left-hand thread lamp, marine lamp, marine signal service lamp, mine service lamp, plant lamp, R20 short lamp, sign service lamp, silver bowl lamp, showcase lamp or traffic signal lamp. (lampe à incandescence standard)

general service incandescent reflector lamp means a lamp in which light is produced by a filament heated to incandescence by an electric current and that

contains an inner reflective coating on the outer bulb to direct the light;

has an R, PAR, ER, BR, BPAR or similar bulb shape with an E26 medium screw base;

has a rated voltage or voltage range that lies at least partially in the range of 115 V to 130 V;

has a diameter exceeding 57 mm (2.25 inches); and

has a rated wattage of 40 W or higher.

It does not include a coloured lamp, rough service lamp, vibration service lamp or R20 short lamp. (lampe-réflecteur à incandescence standard)

general service lamp means, subject to subsection (2), an electrical device that is used in general lighting applications and that

has a base that complies with ANSI C81.61;

is able to operate, in the case of an integrated lamp, at

a voltage of 12 V or 24V,

a voltage ranging from 100 V to 130 V,

a voltage ranging from 220 V to 240 V, or

a voltage of 277 V or 347 V;

is able to operate at any voltage, in the case of a non-integrated lamp; and

has an initial lumen output of

at least 310 lm but no more than 3300 lm, or

in the case of a modified spectrum incandescent lamp, at least 232 lm but no more than 3300 lm.

It includes a CFL, general service incandescent lamp, general service incandescent reflector lamp, general service LED lamp and general service OLED lamp. (lampe standard)

general service LED lamp means an integrated or non-integrated lamp that is designed for use in general lighting applications and that uses light-emitting diodes as the primary source of light. (lampe à DEL standard)

general service OLED lamp means an integrated or non-integrated lamp that is designed for use in general lighting applications and that uses organic light-emitting diodes as the primary source of light. (lampe à DELO standard)

infrared lamp means a lamp that

has its highest radiant power peaks in the infrared region of the electromagnetic spectrum (770 nm to 1 mm);

has a rated wattage of 125 W or greater; and

provides heat as its primary purpose. (lampe infrarouge)

integrated, in relation to a lamp, means containing all of the components necessary for the starting and stable operation of the lamp, not including any replaceable or interchangeable parts, and being connected directly to a branch circuit through a base and corresponding socket that comply with ANSI standards. (intégrée)

LED downlight retrofit kit means a retrofit kit that is designed and marketed to install into an existing downlight for the purpose of replacing the existing light source and related electrical components with a light source that uses light-emitting diodes as the primary source of light. It includes a kit that employs an ANSI standard lamp base, either integrated or connected to the downlight retrofit by wire leads. (ensemble de conversion à DEL)

left-hand thread lamp means a lamp with the direction of threads on the lamp base oriented in the left-hand direction. (lampe à filetage à gauche)

light fixture means a complete lighting unit consisting of at least one light source and at least one ballast or driver, together with the parts designed to distribute the light, to position and protect the light sources and to connect the light sources to the power supply. (luminaire)

marine lamp means a lamp that is designed and marketed for use on boats and that can operate at a voltage ranging from 12 V to 13.5 V. (lampe marine)

modified spectrum incandescent lamp means an incandescent lamp that, when operated at the rated voltage and wattage of the lamp, has a colour point on the CIE 1931 chromaticity diagram, figure 2, page 3 of IES LM16 that lies

below the black-body locus; and

at least 4 MacAdam steps, as referenced in IES LM16, distant from the colour point of a clear lamp with the same filament and bulb shape, operated at the same rated voltage and wattage.

It does not include a coloured lamp. (lampe à incandescence à spectre modifié)

R20 short lamp means a lamp that is an R20 incandescent reflector lamp that is designed, labelled and marketed for pool and spa applications and that

has a rated wattage of 100 W; and

has a maximum overall length of 92 mm (3.625 inches). (lampe courte R20)

reflector lamp means a lamp that has an R, PAR, BPAR, BR, ER, MR or similar bulb shape, as described in ANSI C78.79, and that is used to provide directional light. (lampe-réflecteur)

rough service lamp means a lamp that is marketed as a rough service lamp and has any of the following filament constructions, as illustrated in figure 6.12 of the IES Handbook:

a C-7A or C-11 filament construction with at least five supports exclusive of lead wires;

a C-17 filament construction with eight supports exclusive of lead wires;

a C-22 filament construction with 16 supports exclusive of lead wires. (lampe à construction renforcée)

shatter-resistant lamp means a lamp that is designed and marketed as a shatter-resistant, shatter-proof or shatter-protected lamp and has an external silicone, polytetrafluoroethylene or similar coating applied to it for the purpose of resisting breakage and preventing glass from reaching its environment in the event of breakage. (lampe résistante à l’éclatement)

showcase lamp means a lamp that is designed and marketed for use in a showcase, has a T-shape, as described in ANSI C78.79, and has a maximum rated wattage of 75 W. (lampe de vitrine)

sign service lamp means a vacuum type or gas-filled lamp that is designed and marketed for use in a sign and that

has sufficiently low bulb temperature to permit exposed outdoor use on high-speed flashing circuits; and

has a maximum rated wattage of 15 W. (lampe d’enseigne)

silver bowl lamp means a lamp that is marketed as a silver bowl lamp and that has an opaque reflective coating that is applied directly to a part of the bulb surface so that the light is reflected toward the lamp base. (lampe à calotte argentée)

specialty MR lamp means a lamp that is designed and marketed for a specialty application and that has an MR shape, as described in ANSI C78.79, a diameter of less than or equal to 57 mm (2.25 inches) and a lifetime of 300 hours or less. (lampe MR spécialisée)

three-way incandescent lamp means an incandescent lamp that is marketed as a three-way lamp and that employs two filaments, operated separately and in combination, to provide three light levels. (lampe à incandescence à trois intensités)

traffic signal lamp means a lamp that is designed and marketed for use in a traffic signal module, as defined in section 523, and that has a lifetime of 8000 hours or greater. (lampe de signalisation routière)

TSD D7SB001 means the technical standards document D7SB001 published by the Minister and entitled General Service Lamps: Energy Efficiency Standards for General Service Lamps. (DNT D7SB001)

vibration service lamp means a lamp that is sold at retail in packages of one or two, is designed and marketed as a vibration service lamp and

has a maximum nominal power of 60 W; and

has a C-5, C-7A or C-9 filament construction, as illustrated in figure 6.12 of the IES Handbook, or a similar configuration. (lampe antivibrations)

s. 433(2) — Exclusion — definition of general service lamp

The definition general service lamp in subsection (1) does not include

a light fixture;

an LED downlight retrofit kit;

an appliance lamp;

a black light lamp;

a bug lamp;

a coloured lamp;

a G-shape lamp, as described in ANSI C78.79, with a diameter of 127 mm (5 inches) or more;

a high-intensity discharge lamp;

an infrared lamp;

a J-, JC-, JCD-, JCS-, JCV-, JCX-, JD-, JS- or JT-shape lamp that does not have an Edison screw base as defined in ANSI C81.61;

a lamp that has a wedge base or pre-focus base;

a left-hand thread lamp;

a marine lamp;

a marine signal service lamp;

a mine service lamp;

an MR-shape lamp that has a first number symbol equal to 16 (diameter equal to 51 mm (2 inches)), as described in ANSI C78.79, operates at 12 V and has a lumen output greater than or equal to 800 lm;

a fluorescent lamp other than a CFL;

a plant lamp;

an R20 short lamp;

a reflector lamp that

has a first number symbol less than 16 (diameter less than 51 mm (2 inches)), as described in ANSI C78.79, and

does not have an E26/E24, E26d, E26/50x39, E26/53x39, E29/28, E29/53x39, E39, E39d, EP39 or EX39 base;

an S-shape or G-shape lamp that has a first number symbol less than or equal to 12.5 (diameter less than or equal to 40 mm (1.5625 inches)), as described in ANSI C78.79;

a sign service lamp;

a silver bowl lamp;

a showcase lamp;

a specialty MR lamp;

a T-shape lamp, other than a CFL, that

has a first number symbol less than or equal to 8 (diameter less than or equal to 25 mm (1 inch)), as described in ANSI C78.79, and

has a nominal overall length less than 305 mm (12 inches); or

a traffic signal lamp.

s. 434 — Energy-using product

A general service lamp is prescribed as an energy-using product.

s. 434(2) — Limits

However, for the purposes of sections 4, 5, 435 and 436, a general service lamp is not considered to be an energy-using product if

in the case of a general service incandescent lamp or general service incandescent reflector lamp, it is manufactured before January 1, 2026; or

in any other case, it is manufactured before January 1, 2027.

s. 434.1 — Application of former Regulations

Sections 4, 5, 424 and 430 to 444 of the former Regulations continue to apply in respect of a lamp that is

a CFL, as defined in section 430 of the former Regulations, manufactured before January 1, 2027;

a general service lamp, as defined in subsection 433(1) of the former Regulations, manufactured before January 1, 2026;

a modified spectrum incandescent lamp, as defined in section 437 of the former Regulations, manufactured before January 1, 2026; or

a general service incandescent reflector lamp, as defined in section 441 of the former Regulations, manufactured before January 1, 2026.

s. 434.1(2) — Non-application — early compliance

Subsection (1) does not apply in respect of a lamp that is deemed, under section 436.1, to satisfy the requirements of sections 4, 5, 435 and 436.

s. 435 — Energy efficiency standards

The energy efficiency standards set out in TSD D7SB001 apply to general service lamps.

s. 435(2) — Testing standard

A general service lamp complies with the energy efficiency standard if it meets that standard when tested in accordance with the applicable testing procedures established by 10 C.F.R. §430.23(gg).

s. 436 — Information

For the purposes of subsection 5(1) of the Act, the following information must be provided to the Minister in respect of a general service lamp:

a description of the lamp, collected in accordance with ANSI C78.79; and

the following information, collected in accordance with 10 C.F.R. §430.23(gg):

the rated lumen output or, in the case of a three-way lamp, the three rated lumen outputs, in lumens,

the rated power or, in the case of a three-way lamp, the three values for rated power, in watts,

the rated lamp efficacy, in lm/W,

the rated life, in hours,

the rated correlated colour temperature or range of correlated colour temperatures, in degrees Kelvin, and

the rated colour rendering index.

s. 436.1 — Early compliance

A general service lamp is deemed to satisfy the requirements of sections 4, 5, 435 and 436 if

in the case of a general service incandescent lamp or general service incandescent reflector lamp, it was manufactured on or after January 1, 2024 and before January 1, 2026 and satisfies the requirements of sections 4, 5, 435 and 436 that would have applied to the lamp if it had been manufactured on or after January 1, 2026; and

in any other case, it was manufactured on or after January 1, 2025 and before January 1, 2027 and satisfies the requirements of sections 4, 5, 435 and 436 that would have applied to the lamp if it had been manufactured on or after January 1, 2027.

Modified Spectrum Incandescent Lamps

[Repealed]

[Repealed]

[Repealed]

[Repealed]

[Repealed, SOR/2025-110, s. 69]

[Repealed]

[Repealed]

[Repealed]

[Repealed]

General Service Fluorescent Lamps

s. 445 — Definitions

The following definitions apply in this Subdivision.

10 C.F.R. Appendix R means Appendix R to Subpart B, Part 430 of Title 10 to the United States Code of Federal Regulations, entitled Uniform Test Method for Measuring Average Lamp Efficacy (LE), Color Rendering Index (CRI), and Correlated Color Temperature (CCT) of Electric Lamps, as amended from time to time. (appendice R 10 C.F.R.)

10 C.F.R. §430.32(n)(4) means the table to paragraph 430.32(n)(4) of Subpart C, Part 430 of Title 10 to the United States Code of Federal Regulations, as amended from time to time. (10 C.F.R. §430.32(n)(4))

ANSI C78.81 means the ANSI standard ANSI C78.81-2010 entitled American National Standard for Electric Lamps Double-Capped Fluorescent Lamps — Dimensional and Electrical Characteristics. (ANSI C78.81)

ANSI C78.901 means the ANSI standard ANSI C78.901-2005 entitled American National Standard for Electric Lamps Single — Based Fluorescent Lamps — Dimensional and Electrical Characteristics. (ANSI C78.901)

CSA C819-11 means the CSA standard CAN/CSA-C819-11 entitled Performance of general service fluorescent lamps. (CSA C819-11)

CSA C819-16 means the CSA standard CAN/CSA-C819-16 entitled Performance of General Service Fluorescent Lamps. (CSA C819-16)

CSA C819-95[Repealed, SOR/2018-201, s. 44]

cold temperature fluorescent lamp means a fluorescent lamp that is marketed for outdoor or cold temperature use and that is designed to start at temperatures as low as –29°C (–20°F) when used with a ballast that conforms to the requirements of ANSI C78.81 and ANSI C78.901. (lampe fluorescente pour basses températures)

coloured fluorescent lamp means a fluorescent lamp that has

a colour rendering index of less than 40, as determined in accordance with CIE 13.3; or

a correlated colour temperature of less than 2 500 K or more than 7 000 K, as determined in accordance with the IES standard IES LM-9-09 entitled IES Approved Method for the Electrical and Photometric Measurement of Fluorescent Lamps. (lampe fluorescente colorée)

general service fluorescent lamp means a fluorescent lamp that

is straight-shaped and has a nominal overall length of 1 200 mm (48 inches), a medium bi-pin base and a nominal power of at least 25 W;

is U-shaped and has a nominal overall length of at least 560 mm (22 inches) but not more than 635 mm (25 inches), a medium bi-pin base and a nominal power of at least 25 W;

is rapid-start and straight-shaped and has a nominal overall length of 2 400 mm (96 inches) and a recessed double-contact base;

is instant-start and straight-shaped and has a nominal overall length of 2 400 mm (96 inches), a single-pin base and a nominal power of at least 49 W;

is straight-shaped and standard output and has a nominal overall length of at least 1 125 mm (45 inches) but not more than 1 200 mm (48 inches), a miniature bi-pin base and a nominal power of at least 25 W;

is straight-shaped and high output with a nominal overall length of at least 1 125 mm (45 inches) but not more than 1 200 mm (48 inches), a miniature bi-pin base and a nominal power of at least 44 W; or

is a physical and electrical equivalent of a lamp described in any of paragraphs (a) to (f).

It does not include any of the following:

a fluorescent lamp that is marketed as a plant lamp;

a cold temperature fluorescent lamp;

a coloured fluorescent lamp;

a fluorescent lamp that is designed to be impact-resistant;

a reflectorized or aperture fluorescent lamp;

a fluorescent lamp that is designed for use in reprographic equipment;

a fluorescent lamp that is primarily designed to produce ultraviolet radiation; or

a fluorescent lamp that has a colour rendering index of at least 87. (lampe fluorescente standard)

s. 446 — Energy-using product

A general service fluorescent lamp is prescribed as an energy-using product.

s. 446(2) — Limit

However, for the purpose of section 4, a general service fluorescent lamp is not considered to be an energy-using product unless it is manufactured on or after December 31, 1996.

s. 447 — Energy efficiency standards

The energy efficiency standards set out in column 2 of the table to this section apply to general service fluorescent lamps that are manufactured during the periods set out in column 3.

s. 447(2) — Testing standard

A general service fluorescent lamp complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by the standard set out in column 1 that are applicable to a general service fluorescent lamp as defined in section 445. TABLE Column 1 Column 2 Column 3 Item Testing Standard Energy Efficiency Standard Period of Manufacture 1 CSA C819-11 CSA C819-11, Table 1 On or after December 31, 1996 and before January 26, 2018 2 CSA C819-16 or 10 C.F.R. Appendix R CSA C819-16, Table 1 or average lamp efficacy × 1.011 > minimum average lamp efficacy for the product in 10 C.F.R. §430.32(n)(4) On or after January 26, 2018

s. 448 — Information

For the purpose of subsection 5(1) of the Act, the following information must be provided to the Minister in respect of a general service fluorescent lamp:

its nominal power, expressed in watts;

its shape;

its nominal overall length;

its diameter;

its base type;

its abbreviation under the designation system in ANSI C78.81, Annex A, and ANSI C78.901, Annex B;

its correlated colour temperature;

its average colour rendering index; and

the average lamp efficacy.

s. 448(2) — Standard

The information must be collected in accordance with one of the following standards:

CSA C819-11, if the product was manufactured on or after December 31, 1996 and before January 26, 2018; or

CSA C819-16 or 10 C.F.R. Appendix R, if the product is manufactured on or after January 26, 2018.

Fluorescent Lamp Ballasts

s. 449 — Definitions

The following definitions apply in this Subdivision.

CSA C654-10 means the CSA standard CAN/CSA-C654-10 entitled Fluorescent lamp ballast efficacy measurements. (CSA C654-10)

CSA C654-14 means the CSA standard CAN/CSA-C654-14 entitled Fluorescent lamp ballast efficacy measurements. (CSA C654-14)

fluorescent lamp ballast means a ballast that is

designed to start and operate fluorescent lamps by

providing the necessary voltage and current,

limiting the current during normal operation, and

if necessary to facilitate lamp operation, providing cathode heating;

designed for a nominal voltage of at least 120 V but not more than 347 V; and

described in Table 1A of CSA C654-14.

It does not include any of the following:

a ballast — other than a T12 dimming ballast — that, by means of an integrated dimming capability, is designed to reduce the output of a fluorescent lamp by 50% or more;

a low-frequency T8 ballast that is designed and marketed only for use in an electromagnetic-interference-sensitive environment and that is sold in a package of 10 or fewer; or

a program-start ballast that is designed to operate one or more T8 fluorescent lamps with a nominal overall length of 1 200 mm and a medium bi-pin base, and that delivers an average current of less than 140 mA to each lamp. (ballast pour lampes fluorescentes)

high-frequency means, in respect of a fluorescent lamp ballast, that the ballast operates the lamp at a frequency of 10 kHz or more. (à haute fréquence)

low-frequency means, in respect of a fluorescent lamp ballast, that the ballast operates at a supply frequency of 50 to 60 Hz and operates the lamp at the same frequency as the supply. (à basse fréquence)

10 C.F.R. §430.32(m)(2)(ii)(B) means paragraph 430.32(m)(2)(ii)(B) of Subpart C, Part 430 of Title 10 to the United States Code of Federal Regulations, as amended from time to time. (10 C.F.R. §430.32(m)(2)(ii)(B))

10 C.F.R. Appendix Q means Appendix Q to Subpart B, Part 430 of Title 10 to the United States Code of Federal Regulations, entitled Uniform Test Method for Measuring the Energy Consumption of Fluorescent Lamp Ballasts, as amended from time to time. (appendice Q 10 C.F.R.)

T12 dimming ballast means a fluorescent lamp ballast that

is designed for a nominal voltage of at least 120 V but not more than 277 V;

by means of an integrated dimming capability, is designed to reduce the output of a T12 fluorescent lamp by 50% or more; and

is designed to operate one F34T12 fluorescent lamp or two F34T12, F96T12ES or F96T12HO ES fluorescent lamps. (ballast de gradation T12)

s. 449(2) — Table 1A of CSA C654-14

Despite subsection 1(3), a reference in this Subdivision to Table 1A of CSA C654-14 is a reference to that table as it read on the day on which the standard was published.

s. 450 — Energy-using product

A fluorescent lamp ballast is prescribed as an energy-using product.

s. 450(2) — Limit

However, for the purposes of sections 4, 5 and 451, a fluorescent lamp ballast is not considered to be an energy-using product if

it was manufactured before February 3, 1995; or

it was manufactured on or after February 3, 1995 and before November 14, 2014 and

is a T12 dimming ballast,

is designed to operate a fluorescent lamp other than an F32T8, F34T12, F40T10 or F40T12 rapid-start fluorescent lamp or an F96T12ES, F96T12IS, F96T12HO or F96T12HO ES fluorescent lamp, or

is designed to be used in an outdoor sign and to operate two F96T12HO fluorescent lamps in ambient temperatures at or below –28.9°C.

s. 451 — Energy efficiency standards

The energy efficiency standards set out in column 3 of the table to this section apply to fluorescent lamp ballasts described in column 1 that are manufactured during the periods described in column 4.

s. 451(2) — Testing standard

A fluorescent lamp ballast complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by the standard set out in column 2 that are applicable to a fluorescent lamp ballast as defined in section 449. TABLE Column 1 Column 2 Column 3 Column 4 Item Energy-using Product Testing Standard Energy Efficiency Standard Period of Manufacture 1 Fluorescent lamp ballasts CSA C654-10 On or after February 3, 1995 and before November 14, 2014 2 Fluorescent lamp ballasts, other than T12 dimming ballasts CSA C654-14 or 10 C.F.R. Appendix Q On or after November 14, 2014 3 T12 dimming ballasts that are low-frequency and designed to operate one F34T12 lamp CSA C654-14 or 10 C.F.R. Appendix Q On or after November 14, 2014 4 T12 dimming ballasts that are high-frequency and designed to operate one F34T12 lamp CSA C654-14 or 10 C.F.R. Appendix Q On or after November 14, 2014 5 T12 dimming ballasts that are low-frequency and designed to operate two F34T12 lamps CSA C654-14 or 10 C.F.R. Appendix Q On or after November 14, 2014 6 T12 dimming ballasts that are high-frequency and designed to operate two F34T12 lamps CSA C654-14 or 10 C.F.R. Appendix Q On or after November 14, 2014 7 T12 dimming ballasts that are low-frequency and designed to operate two F96T12/ES lamps CSA C654-14 or 10 C.F.R. Appendix Q On or after November 14, 2014 8 T12 dimming ballasts that are high-frequency and designed to operate two F96T12/ES lamps CSA C654-14 or 10 C.F.R. Appendix Q On or after November 14, 2014 9 T12 dimming ballasts that are low-frequency and designed to operate two F96T12HO/ES lamps CSA C654-14 or 10 C.F.R. Appendix Q On or after November 14, 2014 10 T12 dimming ballasts that are high-frequency and designed to operate two F96T12HO/ES lamps CSA C654-14 or 10 C.F.R. Appendix Q On or after November 14, 2014

s. 452 — Information

For the purpose of subsection 5(1) of the Act, the information set out in column 3 of the table to this section must be collected in accordance with the standard set out in column 2 and provided to the Minister in respect of a fluorescent lamp ballast described in column 1. TABLE Column 1 Column 2 Column 3 Item Energy-using Product Testing Standard Information 1 Fluorescent lamp ballasts manufactured on or after February 3, 1995 and before November 14, 2014 CSA C654-10 2 Fluorescent lamp ballasts manufactured on or after November 14, 2014, other than T12 dimming ballasts CSA C654-14 3 T12 dimming ballasts manufactured on or after November 14, 2014 CSA C654-14

Metal Halide Lamp Ballasts

s. 453 — Definitions

The following definitions apply in this Subdivision.

CSA C863-16 means the CSA standard CAN/CSA C863-16 entitled Energy efficiency of high-intensity discharge (HID) and low-pressure sodium (LPS) lamp ballasts. (CSA C863-16)

electronic ballast means a ballast that is controlled by a transistor, thyristor or other active electronic component and in which impedance is provided by capacitive or inductive reactance. (ballast électronique)

magnetic-regulated lamp ballast means a ballast that operates at a lagging high power factor and that has

three coils;

isolated secondary windings; and

a constant-voltage regulator that, in conjunction with capacitive reactance, provides power factor correction and lamp wattage regulation. (ballast à régulation magnétique)

metal halide lamp ballast means a device that is used to obtain the voltage, current and waveform necessary for starting and operating a metal halide lamp that has a nominal power of at least 50 W but not more than 1 000 W. It does not include any of the following:

a magnetic-regulated lamp ballast;

a replacement metal halide lamp ballast; or

an electronic ballast that is designed for a nominal voltage of 480 V or to operate a lamp at an output frequency of 1000 Hz or more. (ballast pour lampes aux halogénures métalliques)

replacement metal halide lamp ballast means a ballast that is marketed for use as replacement ballast for a metal halide luminaire installation and that is sold in a package of 10 or fewer. (ballast pour lampes aux halogénures métalliques de remplacement)

10 C.F.R. §431.324 means section 431.324 of Subpart S, Part 431 of Title 10 to the United States Code of Federal Regulations, as amended from time to time. (10 C.F.R. §431.324)

s. 454 — Energy-using product

A metal halide lamp ballast is prescribed as an energy-using product.

s. 454(2) — Limit

However, for the purposes of sections 4, 5 and 455, a metal halide lamp ballast is not considered to be an energy-using product if

it was manufactured before February 10, 2017; or

it is manufactured before December 31, 2019 and is capable of using a nominal voltage of 347 V.

s. 455 — Energy efficiency standards

The energy efficiency standards set out in Table 3 of CSA C863-16 apply to metal halide lamp ballasts.

s. 455(2) — Testing standard

A metal halide lamp ballast complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by CSA C863-16 or 10 C.F.R. §431.324 that are applicable to a metal halide lamp ballast as defined in section 453.

s. 456 — Information

For the purpose of subsection 5(1) of the Act, the following information must be collected in accordance with CSA C863-16 and provided to the Minister in respect of a metal halide lamp ballast:

its type;

the efficiency of the lamp and ballast combination, expressed as a percentage;

its nominal voltage;

its input power, in watts;

the power, in watts, of the lamps that the ballast is designed to operate; and

its power factor.

Lighting Fixtures

Interpretation

s. 506 — Definitions

The following definitions apply in this Division.

CSA C22.2 No. 250.0 means the CSA standard C22.2 No. 250.0-08 entitled Luminaires. (CSA C22.2 No. 250.0)

ITE VTCSH[Repealed, SOR/2018-201, s. 52]

pin-based means, with respect to a socket of a ceiling fan or ceiling fan light kit, one that is designed to hold a fluorescent lamp that is not integrally ballasted and that has a plug-in lamp base. It does not include a GU-24 socket. (à broche)

Torchieres

s. 507 — Definitions

The following definitions apply in this Subdivision.

CSA C22.2 No. 250.4 means the CSA standard C22.2 No. 250.4-14 entitled Portable luminaires. (CSA C22.2 No. 250.4)

torchiere means a portable luminaire that has a reflector bowl or similar-shaped reflector that directs light in a predominantly upward direction for the purpose of providing indirect lighting and that may be equipped with one or more additional sockets intended for other lighting functions. (torchère)

s. 508 — Energy-using product

A torchiere is prescribed as an energy-using product.

s. 508(2) — Limit

However, for the purposes of sections 4, 5 and 509, a torchiere is not considered to be an energy-using product unless it is manufactured on or after January 1, 2007.

s. 509 — Energy efficiency standards

The energy efficiency standards set out in column 2 of the table to this section apply to torchieres described in column 1 that are manufactured during the periods set out in column 3.

s. 509(2) — Testing standard

A torchiere complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by CSA C22.2 No. 250.4 that are applicable to a torchiere as defined in section 507. TABLE Column 1 Column 2 Column 3 Item Energy-using Product Energy Efficiency Standard Period of Manufacture 1 Torchieres that have no additional sockets Total power ≤ 190 W On or after January 1, 2007 and before January 1, 2010 2 Torchieres that have no additional sockets Total power ≤ 75 W On or after January 1, 2010 3 Torchieres that have one or more additional sockets Total power ≤ 230 W On or after January 1, 2007 and before January 1, 2010 4 Torchieres that have one or more additional sockets Total power ≤ 100 W On or after January 1, 2010

s. 510 — Information

For the purpose of subsection 5(1) of the Act, the following information must be collected in accordance with CSA C22.2 No. 250.4 and provided to the Minister in respect of a torchiere:

information that indicates whether the product has lighting functions additional to those of the bowl; and

the total power, expressed in watts, for all lighting functions.

[Repealed, SOR/2018-201, s. 53]

[Repealed]

[Repealed]

[Repealed]

[Repealed]

Ceiling Fan Light Kits

s. 515 — Definitions

The following definitions apply in this Subdivision.

ceiling fan light kit means equipment that is designed to provide light from a ceiling fan and that is

integral to the fan before its retail sale; or

attachable to the fan after its retail sale. (ensemble d’éclairage pour ventilateurs de plafond)

integrated solid-state lighting circuitry[Repealed, SOR/2024-54, s. 1]

non-consumer-replaceable solid-state lighting means the lighting system in a ceiling fan light kit for which the solid-state lighting light source and all components necessary for the starting and stable operation of the light source – that is, the driver, heat sink, intermediate circuitry – cannot be replaced by the consumer without permanently altering the ceiling fan light kit. Furthermore, if the lighting system fails, the entire ceiling fan light kit must be replaced. (éclairage à semi-conducteurs non remplaçable par le consommateur)

10 C.F.R. §430.23(x)(1) means paragraph 430.23(x)(1) of Subpart B, Part 430 of Title 10 to the United States Code of Federal Regulations, as amended from time to time. (10 C.F.R. §430.23(x)(1))

10 C.F.R. §430.32(s)(6) means the table to paragraph 430.32(s)(6) of Subpart C, Part 430 of Title 10 to the United States Code of Federal Regulations, as amended from time to time. (10 C.F.R. §430.32(s)(6))

s. 516 — Energy-using product

A ceiling fan light kit is prescribed as an energy-using product.

s. 516(2) — Limits

However, a ceiling fan light kit is not considered to be an energy-using product

for the purposes of sections 4 and 5, if it was manufactured before January 1, 2010; and

for the purpose of section 517,

if it was manufactured before January 1, 2010,

if it is manufactured on or after January 1, 2010 and before January 7, 2019, it has a total power less than or equal to 10 W or only pin-based sockets, or

if it is manufactured on or after January 7, 2019, it has at least one socket, has maximum wattage markings on each socket that together indicate that the combined total power for the lighting is less than or equal to 70 W and does not have non-consumer-replaceable solid-state lighting.

s. 517 — Energy efficiency standards

The energy efficiency standards set out in column 3 of the table to this section apply to ceiling fan light kits described in column 1 that are manufactured during the periods set out in column 4.

s. 517(2) — Testing standard

A ceiling fan light kit complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by the standard set out in column 2 that are applicable to a ceiling fan light kit as defined in section 515. TABLE Column 1 Column 2 Column 3 Column 4 Item Energy-using Product Testing Standard Energy Efficiency Standard Period of Manufacture 1 Ceiling fan light kits CSA C22.2 No. 250.0 Total power for lighting ≤ 190 W On or after January 1, 2010 and before January 7, 2019 2 Ceiling fan light kits that have at least one socket, that are not packaged with a lamp for each socket and that do not have non-consumer-replaceable solid-state lighting CSA C22.2 No. 250.0 Total power for lighting ≤ 70 W On or after January 7, 2019 3 Ceiling fan light kits that have at least one socket, that are packaged with a lamp for each socket and that do not have non-consumer-replaceable solid-state lighting 10 C.F.R. §430.23(x)(1) Lighting efficacy ≥ minimum required efficacy in 10 C.F.R. §430.32(s)(6) On or after January 7, 2019 4 Ceiling fan light kits that have non-consumer-replaceable solid-state lighting 10 C.F.R. §430.23(x)(1) Lighting efficacy ≥ minimum required efficacy in 10 C.F.R. §430.32(s)(6) On or after January 7, 2019

s. 518 — Information

For the purpose of subsection 5(1) of the Act, the following information must be provided to the Minister in respect of a ceiling fan light kit:

if it has at least one socket, the type of socket and the number of each type of socket;

if it has non-consumer-replaceable solid-state lighting, the lighting efficacy, expressed in lumens per watt, and the total light output, expressed in lumens;

if it has a pin-based socket, the ballast type;

if it is packaged with lamps, their type, brand name and model number; and

the total power for the lighting, expressed in watts.

s. 518(2) — Standard

The information must be collected in accordance with CSA C22.2 No. 250.0 or 10 C.F.R. §430.23(x)(1).

Exit Signs

s. 519 — Definitions

The following definitions apply in this Subdivision.

CSA C860 means the CSA standard CAN/CSA C860-11 entitled Performance of Internally Lighted Exit Signs. (CSA C860)

exit sign has the same meaning as in CSA C860. It does not include an exit sign that flashes or that is photoluminescent or radioluminescent. (enseigne de sortie)

legend means any of the following that is displayed on an exit sign:

a representation of a running person, as described in Annex B.1 of the CSA standard CSA C22.2 No. 141 entitled Emergency lighting equipment; and

the word “EXIT” or “SORTIE”. (légende)

s. 520 — Energy-using product

An exit sign is prescribed as an energy-using product.

s. 520(2) — Limit

However, for the purpose of section 4, an exit sign is not considered to be an energy-using product unless it is manufactured on or after November 1, 2004.

s. 521 — Energy efficiency standards

The energy efficiency standards set out in column 2 of the table to this section apply to exit signs described in column 1.

s. 521(2) — Testing standard

An exit sign complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by CSA C860 that are applicable to an exit sign as defined in section 519. TABLE Column 1 Column 2 Item Energy-using Product Energy Efficiency Standard 1 Type 1 and Type 2 exit signs Wattage ≤ 5 W × (number of legends) 2 Type 3 exit signs Wattage ≤ 5 W × (number of legends) + 5 W

s. 522 — Information

For the purpose of subsection 5(1) of the Act, the following information must be collected in accordance with CSA C860 and provided to the Minister in respect of an exit sign:

its type;

its power consumption, expressed in watts; and

the number of legends.

Traffic Signal Modules

s. 523 — Definitions

The following definitions apply in this Subdivision.

traffic signal module means a self-contained device that is designed to

fit into a traffic signal housing; and

provide drivers with movement information by means of a red or green traffic signal indicator that has a nominal diameter of 200 mm (8 inches) or 300 mm (12 inches). (module de signalisation routière)

VTCSH Arrow means the Institute of Transportation Engineers standard entitled Vehicle Traffic Control Signal Heads: Light Emitting Diode (LED) Vehicle Arrow Traffic Signal Supplement, dated July 1, 2007. (VTCSH Arrow)

VTCSH Circular means the Institute of Transportation Engineers standard entitled Vehicle Traffic Control Signal Heads: Light Emitting Diode (LED) Circular Signal Supplement, dated June 27, 2005. (VTCSH Circular)

s. 524 — Energy-using product

A traffic signal module is prescribed as an energy-using product.

s. 524(2) — Limit

However, for the purposes of sections 4, 5 and 525, a traffic signal module is not considered to be an energy-using product unless it is manufactured on or after January 1, 2007.

s. 525 — Energy efficiency standards

The energy efficiency standards set out in column 3 of the table to this section apply to traffic signal modules described in column 1.

s. 525(2) — Testing Procedures

For the purpose of subsection (1), the maximum power and nominal power of a traffic signal module must be determined in accordance with the following procedures: TABLE Column 1 Column 2 Column 3 Item Energy-using Product Testing Standard Energy Efficiency Standard 1 Traffic signal modules that have a red traffic signal indicator that has a nominal diameter of 200 mm (8 inches) VTCSH Circular 2 Traffic signal modules that have a red traffic signal indicator that has a nominal diameter of 300 mm (12 inches) VTCSH Circular 3 Traffic signal modules that have a green traffic signal indicator that has a nominal diameter of 200 mm (8 inches) VTCSH Circular 4 Traffic signal modules that have a green traffic signal indicator that has a nominal diameter of 300 mm (12 inches) VTCSH Circular 5 Traffic signal modules that have a red arrow traffic signal indicator VTCSH Arrow 6 Traffic signal modules that have a green arrow traffic signal indicator VTCSH Arrow

the luminous intensity of the product must be determined in accordance with the procedures established by the standard set out in column 2 that are applicable to a traffic signal module as defined in section 523;

the product’s power must be measured using a watt meter that has an accuracy of ± 1%;

when determining the product’s maximum power, the product must be

mounted in a temperature testing chamber with the lens portion of the product outside the chamber, and

operated for a minimum of 60 minutes at a temperature of 74°C and with the temperature in front of the lens maintained at a minimum of 49°C; and

when determining the product’s nominal power, the product must be operated for a minimum of 60 minutes at an ambient temperature of 25°C.

s. 526 — Information

For the purpose of subsection 5(1) of the Act, the following information must be provided to the Minister in respect of a traffic signal module:

its type;

its maximum power, expressed in watts; and

its nominal power, expressed in watts.

s. 526(2) — Standard

The information must be collected in accordance with

VTCSH Arrow, if the traffic signal module has an arrow traffic signal indicator; or

VTCSH Circular, if the traffic signal module has any other traffic signal indicator.

Pedestrian Modules

s. 527 — Definitions

The following definitions apply in this Subdivision.

pedestrian module means a self-contained device that is designed

to fit into a pedestrian signal housing; and

to provide pedestrians with movement information by means of a walking person display or a hand display but not by means of a countdown message. (module de signalisation piétonnière)

PTCSI means the Institute of Transportation Engineers standard entitled Pedestrian Traffic Control Signal Indicators: Light Emitting Diode (LED) Signal Modules, dated August 4, 2010. (PTCSI)

s. 528 — Energy-using product

A pedestrian module is prescribed as an energy-using product.

s. 528(2) — Limit

However, for the purposes of sections 4, 5 and 529, a pedestrian module is not considered to be an energy-using product unless it is manufactured on or after January 1, 2007.

s. 529 — Energy efficiency standards

The energy efficiency standards set out in column 2 of the table to this section apply to pedestrian modules described in column 1.

s. 529(2) — Testing Procedures

For the purpose of subsection (1), the maximum power and nominal power of a pedestrian module must be determined in accordance with the following procedures: TABLE Column 1 Column 2 Item Energy-using Product Energy Efficiency Standard 1 Pedestrian modules that have a walking person display and a hand display 2 Pedestrian modules that have a walking person display only 3 Pedestrian modules that have a hand display only

the luminous intensity of the product must be determined in accordance with the procedures established by PTCSI that are applicable to a pedestrian module as defined in section 527;

the product’s power must be measured using a watt meter that has an accuracy of ± 1%;

when determining the product’s maximum power, the product must be

mounted in a temperature testing chamber with the lens portion of the product outside the chamber, and

operated for a minimum of 60 minutes at a temperature of 74°C and with the temperature in front of the lens maintained at a minimum temperature of 49°C; and

when determining the product’s nominal power, the product must be operated for a minimum of 60 minutes at an ambient temperature of 25°C.

s. 530 — Information

For the purpose of subsection 5(1) of the Act, the following information must be collected in accordance with PTCSI and provided to the Minister in respect of a pedestrian module:

its type;

its maximum power, expressed in watts; and

its nominal power, expressed in watts.

Electronic Products

Interpretation

s. 573 — Definitions

The following definitions apply in this Division.

CSA C62301 means the CSA standard CAN/CSA-C62301:11 entitled Household electrical appliances – Measurement of standby power. (CSA C62301)

information display means a clock or other device that provides visual alphanumeric or graphical information or indicates the status of the equipment. (affichage)

medical device has the same meaning as in section 1 of the Medical Devices Regulations. (instrument médical)

Compact Audio Products

s. 574 — Definitions

The following definitions apply in this Subdivision.

compact audio product means a product that consists of an amplifier and a terrestrial tuner that are encased in a single housing — including a product that can produce sound from another media — and that uses mains power as at least one source of power and has attached or separable speakers. (produit audio compact)

off mode means the mode in which the product, while connected to mains power, cannot produce sound or provide any mechanical function and cannot be switched into another mode except by means of a manual switch on the product. (mode arrêt)

standby mode means the mode in which the product, while connected to mains power,

is not producing sound, providing mechanical function or exchanging data with, or receiving it from, an external source; and

can be switched into another mode with a remote control unit, an internal signal or an internal timer. (mode veille)

s. 575 — Energy-using product

A compact audio product is prescribed as an energy-using product.

s. 575(2) — Limit

However, for the purposes of sections 4, 5 and 576, a compact audio product is not considered to be an energy-using product unless it is manufactured on or after May 1, 2011.

s. 576 — Energy efficiency standards

The energy efficiency standards set out in column 2 of the table to this section apply to compact audio products described in column 1 that are manufactured during the periods set out in column 3.

s. 576(2) — Testing standard

A compact audio product complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by CSA C62301 that are applicable to a compact audio product as defined in section 574. TABLE Column 1 Column 2 Column 3 Item Energy-using Product Energy Efficiency Standard Period of Manufacture 1 Compact audio products On or after May 1, 2011 and before January 1, 2013 2 Compact audio products, other than clock radios On or after January 1, 2013 3 Compact audio products that are clock radios On or after January 1, 2013

s. 577 — Information

For the purpose of subsection 5(1) of the Act, the following information must be collected in accordance with CSA C62301 and provided to the Minister in respect of a compact audio product:

its type;

if it was manufactured before January 1, 2013 and has standby mode, its power consumption in that mode, expressed in watts;

if it is manufactured on or after January 1, 2013 and has standby mode, its power consumption in that mode, expressed in watts, as applicable,

with the information display active,

with the information display inactive, and

without the information display;

if it has standby mode, the period, expressed in minutes, that begins when standby mode is enabled and ends when the measurement of power consumption in that mode is completed; and

if it has off mode, its power consumption, expressed in watts, in off mode.

Video Products

s. 578 — Definitions

The following definitions apply in this Subdivision.

off mode means the mode in which the product, while connected to mains power, cannot provide any mechanical function and cannot be switched into another mode with a remote control unit, a timer or another internal or external signal. (mode arrêt)

standby mode means the mode in which the product, while connected to mains power,

is not producing video or audio output signals, providing any mechanical function or exchanging data with, or receiving it from, an external source; and

can be switched into another mode with a remote control unit, an internal signal or an internal timer. (mode veille)

video product means a household electronic product that is encased in a single housing, requires a power supply device in order to operate and is designed

to be connected to mains power; and

primarily to do one or both of the following, namely, produce audio and video signals from, or record those signals to, digital or analog media.

It does not include a camera or a portable DVD player that has both an integral display screen and a DC power source. (appareil vidéo)

s. 579 — Energy-using product

A video product is prescribed as an energy-using product.

s. 579(2) — Limit

However, for the purposes of sections 4, 5 and 580, a video product is not considered to be an energy-using product unless it is manufactured on or after May 1, 2011.

s. 580 — Energy efficiency standards

The energy efficiency standards set out in column 1 of the table to this section apply to video products that are manufactured during the periods set out in column 2.

s. 580(2) — Testing standard

A video product complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by CSA C62301 that are applicable to a video product as defined in section 578. TABLE Column 1 Column 2 Item Energy Efficiency Standard Period of Manufacture 1 On or after May 1, 2011 and before January 1, 2013 2 On or after January 1, 2013

s. 581 — Information

For the purpose of subsection 5(1) of the Act, the following information must be collected in accordance with CSA C62301 and provided to the Minister in respect of a video product:

if it was manufactured before January 1, 2013 and has standby mode, its power consumption in that mode, expressed in watts;

if it is manufactured on or after January 1, 2013 and has standby mode, its power consumption in that mode, expressed in watts, as applicable,

with the information display active,

with the information display inactive, and

without the information display;

if it has standby mode, the period, expressed in minutes, that begins when standby mode is enabled and ends when the measurement of power consumption in that mode is completed;

if it has off mode, its power consumption, expressed in watts, in off mode; and

the type of playback or recording technology that it has.

Televisions

s. 582 — Definitions

The following definitions apply in this Subdivision.

off mode means the mode in which the product, while connected to mains power, cannot produce either sound or picture or provide any mechanical function and cannot be switched into another mode with a remote control unit, a timer or another internal or external signal. (mode arrêt)

standby mode means the mode in which the product, while connected to mains power,

is not producing sound or picture, providing any mechanical function or exchanging data with, or receiving it from, an external source; and

can be switched into another mode with a remote control unit, an internal signal or an internal timer. (mode veille)

television means an analog or digital product, with or without an internal tuner, that is designed primarily for the display and reception of a terrestrial, satellite, cable, Internet Protocol TV or other broadcast or recorded transmission of analog or digital video and audio signals and includes

a combination television system in which a television and one or more other devices are encased as a single unit in the television casing; and

a component television that has two or more separate components and that is marketed and sold as a television under one model or system designation.

It does not include

a television that is marketed exclusively for commercial use and is without an internal tuner; or

a television that is marketed primarily for use as a computer monitor. (téléviseur)

s. 583 — Energy-using product

A television is prescribed as an energy-using product.

s. 583(2) — Limit

However, for the purposes of sections 4, 5 and 584, a television is not considered to be an energy-using product unless it is manufactured on or after May 1, 2011.

s. 584 — Energy efficiency standards

The energy efficiency standards set out in column 1 of the table to this section apply to televisions that are manufactured during the periods set out in column 2.

s. 584(2) — Testing standard

A television complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by CSA C62301 that are applicable to a television as defined in section 582. TABLE Column 1 Column 2 Item Energy Efficiency Standard Period of Manufacture 1 On or after May 1, 2011 and before January 1, 2013 2 On or after January 1, 2013

s. 585 — Information

For the purpose of subsection 5(1) of the Act, the following information must be collected in accordance with CSA C62301 and provided to the Minister in respect of a television:

if it was manufactured before January 1, 2013 and has standby mode, its power consumption in that mode, expressed in watts;

if it is manufactured on or after January 1, 2013 and has standby mode, its power consumption in that mode, expressed in watts, as applicable,

with the information display active,

with the information display inactive, and

without the information display;

if it has standby mode, the period, expressed in minutes, that begins when standby mode is enabled and ends when the measurement of power consumption in standby mode is completed; and

if it has off mode, its power consumption, expressed in watts, in off mode.

External Power Supplies

s. 586 — Definitions

The following definitions apply in this Subdivision.

adaptive external power supply means an external power supply that, without user intervention and while it is connected to mains power and each output is connected to a load, can alter the output voltage using a digital communication protocol with the end-use product. (bloc d’alimentation externe adaptatif)

CSA C381.1 means the CSA standard CAN/CSA-C381.1-08 entitled Test method for calculating the energy efficiency of single-voltage external ac-ac and ac-ac power supplies. (CSA C381.1)

CSA C381.1-17 means the CSA standard CAN/CSA C381.1-17 entitled Energy performance of external ac-dc and ac-ac power supplies. (CSA C381.1-17)

detachable battery pack means a battery that is encased in an enclosure separate from an end-use product and that is designed to be removed or disconnected from the end-use product for recharging. (bloc-batterie amovible)

direct operation external power supply means a power supply device that is capable of operating an end-use product, other than a battery charger, without the assistance of a battery. (bloc d’alimentation externe à fonctionnement direct)

external power supply means a single-voltage external power supply or a multiple-voltage external power supply that is designed to be used with a household or office end-use product that constitutes the primary load. It does not include

a direct operation external power supply that has a nominal output voltage of less than 3 V and a nominal output current of 1 000 mA or more and that charges the battery of an end-use product that is fully or primarily motor-operated;

an indirect operation external power supply that has a nominal output power of greater than 250 W;

a device that powers the charger of a detachable battery pack of an end-use product;

a device that is an accessory to a medical device; or

a device that is solely designed to power solid-state lighting or a ceiling fan that has a direct current motor. (bloc d’alimentation externe)

indirect operation external power supply means a power supply device that can only operate an end-use product with the assistance of a battery. (bloc d’alimentation externe à fonctionnement indirect)

multiple-voltage external power supply means a device that is designed to convert line voltage AC input into more than one simultaneous lower voltage AC or DC outputs. (bloc d’alimentation externe à tensions multiples)

replacement external power supply means an external power supply that is marked as a replacement to be used with a specific end-use product that was manufactured before July 1, 2017. (bloc d’alimentation externe de remplacement)

security external power supply means an external power supply manufactured before July 1, 2017 that

is designed to convert line voltage AC into lower voltage AC output;

has a nominal output power of 20 W or more; and

is designed for and marketed with equipment that operates continuously in on mode to perform any of the following principal functions:

to monitor, detect, record or provide notification of any intrusion on real property or immovables, or access to real property or immovables or physical assets,

to provide notification of threats to personal safety resulting from an intrusion or access referred to in subparagraph (i),

to monitor, detect, record or provide notification of fire, gas, smoke, flooding or any other physical threats to real property or immovables, physical assets or personal safety, or

to deter or control access to real property or immovables or physical assets or prevent the unauthorized removal of physical assets.

It includes an external power supply for equipment that is designed and marketed with a built-in alarm or theft-deterrent feature and whose principal functions are those referred to in paragraph (c). (bloc d’alimentation externe de sécurité)

single-voltage external power supply means a device that is designed to convert line voltage AC input into only one lower AC or DC voltage output at a time. (bloc d’alimentation externe à simple tension)

10 C.F.R. Appendix Z means Appendix Z to Subpart B, Part 430 of Title 10 to the United States Code of Federal Regulations, entitled Uniform Test Method for Measuring the Energy Consumption of External Power Supplies, as amended from time to time. (appendice Z 10 C.F.R.)

10 C.F.R. §430.32(w)(1)(i) means the table to paragraph 430.32(w)(1)(i) of Subpart C, Part 430 of Title 10 to the United States Code of Federal Regulations, as amended from time to time. (10 C.F.R. §430.32(w)(1)(i))

verification mark has the same meaning as in section 2. (marque de vérification)

[Repealed]

s. 587 — Energy-using product

An external power supply is prescribed as an energy-using product.

s. 587(2) — Limit

However, an external power supply is not considered to be an energy-using product

for the purposes of sections 4 and 5 if

it was manufactured before July 1, 2010, or

it was manufactured on or after July 1, 2010 and before July 1, 2017 and

it is a multiple-voltage external power supply or an adaptive external power supply,

it is a direct operation external power supply that has a nominal output power of greater than 250 W, or

it is an indirect operation external power supply that has a nominal output voltage of greater than 3 V and a nominal output current of less than 1 000 mA and that charges the battery of an end-use product that is fully or primarily motor-operated; and

for the purpose of section 588 if

it was manufactured before July 1, 2010,

it was manufactured on or after July 1, 2010 and before July 1, 2017 and

it is a multiple-voltage external power supply or an adaptive external power supply,

it is a direct operation external power supply that has a nominal output power of greater than 250 W, or

it is an indirect operation external power supply that has a nominal output voltage of greater than 3 V and a nominal output current of less than 1 000 mA and that charges the battery of an end-use product that is fully or primarily motor-operated, or

it was manufactured before July 1, 2013 and is a replacement external power supply.

s. 588 — Energy efficiency standards

The energy efficiency standards set out in column 3 of the table to this section apply to external power supplies described in column 1 that are manufactured during the periods set out in column 4.

s. 588(2) — Testing standard

An external power supply complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by the standard set out in column 2 that are applicable to an external power supply as defined in subsection 586(1). TABLE Column 1 Column 2 Column 3 Column 4 Item Energy-using Product Testing Standard Energy Efficiency Standard Period of Manufacture 1 External power supplies, other than replacement external power supplies CSA C381.1 or 10 C.F.R. Appendix Z 10 C.F.R. §430.32(w)(1)(i) for efficiency in active mode and, if product is not a security external power supply, power in no-load mode ≤ 0.5 W On or after July 1, 2010 and before July 1, 2017 2 Direct operation external power supplies other than replacement external power supplies CSA C381.1-17 or 10 C.F.R. Appendix Z CSA C381.1-17, Table D.1, for efficiency in active mode and power in no-load mode On or after July 1, 2017 3 Indirect operation external power supplies other than replacement external power supplies CSA C381.1 or 10 C.F.R. Appendix Z 10 C.F.R. §430.32(w)(1)(i) for efficiency in active mode and, if product is not a security external power supply, power in no-load mode ≤ 0.5 W On or after July 1, 2017 4 Replacement external power supplies CSA C381.1 or 10 C.F.R. Appendix Z 10 C.F.R. §430.32(w)(1)(i) for efficiency in active mode and, if product is not a security external power supply, power in no-load mode ≤ 0.5 W On or after July 1, 2013 and before February 10, 2020 5 Replacement external power supplies CSA C381.1-17 or 10 C.F.R. Appendix Z CSA C381.1-17, Table D.1, for efficiency in active mode and power in no-load mode On or after February 10, 2020

s. 589 — Information

For the purpose of subsection 5(1) of the Act, the following information must provided to the Minister in respect of an external power supply:

information that indicates whether the product is a single-voltage external power supply or a multiple-voltage external power supply;

for each voltage output, its nominal output voltage at the highest and lowest settings and information that indicates whether that voltage is AC or DC;

its nominal output power, expressed in watts, at the highest and lowest power settings, if applicable;

its average efficiency at the highest and lowest power settings, if applicable;

its power in no-load mode, expressed in watts;

the Roman numeral mark, if applicable;

information that indicates whether the product bears a verification mark; and

information that indicates whether the product is a replacement external power supply or a security external power supply and, if it is one of those power supplies, the end-use product or equipment, as applicable, and the model number and brand of that end-use product or equipment.

s. 589(2) — Standard

The information must be collected in accordance with a standard set out in column 2 of the table to this section in respect of an external power supply described in column 1. TABLE Column 1 Column 2 Item Energy-using Product Testing Standard 1 External power supplies, other than replacement external power supplies, that are manufactured on or after July 1, 2010 and before July 1, 2017 CSA C381.1 or 10 C.F.R. Appendix Z 2 Direct operation external power supplies, other than replacement external power supplies, that are manufactured on or after July 1, 2017 CSA C381.1-17 or 10 C.F.R. Appendix Z 3 Indirect operation external power supplies, other than replacement external power supplies, that are manufactured on or after July 1, 2017 CSA C381.1 or 10 C.F.R. Appendix Z 4 Replacement external power supplies that are manufactured on or after July 1, 2013 and before February 10, 2020 CSA C381.1 or 10 C.F.R. Appendix Z 5 Replacement external power supplies that are manufactured on or after February 10, 2020 CSA C381.1-17 or 10 C.F.R. Appendix Z

Battery Chargers

s. 590 — Definitions

The following definitions apply in this Subdivision.

backup battery charger means a device that

is incorporated into an end-use product, including a device that is incorporated into an uninterruptible power supply or that uses an external power supply, that is designed to operate continuously using mains power; and

recharges a battery that is used to maintain the continuity of electrical power to the end-use product such that the product can continue its full or partial operation in the event of a failure of mains power. (chargeur de batterie de secours)

battery charger means a device that charges the battery of a wheelchair, golf cart, low-speed vehicle or any other end-use product. It does not include any of the following:

a device that charges the battery of a vehicle other than a wheelchair, golf cart or low-speed vehicle;

a device that charges the battery of a medical device;

a wireless battery charger, other than a wireless battery charger that is inductive and designed for wet environments; or

a backup battery charger. (chargeur de batterie)

CSA C381.2-17 means the CSA standard CSA C381.2-17 entitled Energy performance of battery-charging systems and uninterruptible power supplies. (CSA C381.2-17)

low-speed vehicle means a vehicle that

does not use fuel as an on-board source of energy;

travels on two or more wheels;

is powered by an electric power train that is designed to allow the vehicle to attain a speed of no greater than 40 km/h over a distance of 1.6 km on a paved level surface; and

has a loaded weight, as specified by its manufacturer, of less than 1 361 kg. (véhicule à basse vitesse)

10 C.F.R. Appendix Y means Appendix Y to Subpart B, Part 430 of Title 10 to the United States Code of Federal Regulations, entitled Uniform Test Method for Measuring the Energy Consumption of Battery Chargers, as amended from time to time. (appendice Y 10 C.F.R.)

s. 591 — Energy-using product

A battery charger is prescribed as an energy-using product.

s. 591(2) — Limit

However, for the purposes of sections 4, 5 and 592, a battery charger is not considered to be an energy-using product unless it is manufactured on or after June 13, 2019.

s. 592 — Energy efficiency standard

A battery charger must have a unit energy consumption that is less than or equal to that set out for the battery charger’s product class in Table C.1 of CSA C381.2-17.

s. 592(2) — Testing standards

A battery charger complies with the energy efficiency standard if it meets that standard when tested in accordance with the testing procedures established by CSA C381.2-17 or 10 C.F.R. Appendix Y that are applicable to a battery charger as defined in section 590.

s. 593 — Information

For the purpose of subsection 5(1) of the Act, the following information must be collected in accordance with CSA C381.2-17 or 10 C.F.R. Appendix Y and provided to the Minister in respect of a battery charger:

its product class;

its rated battery energy (E batt), expressed in watt-hours;

its unit energy consumption, expressed in kilowatt-hours per year;

its power, expressed in watts, when it is in active mode, maintenance mode and standby mode, respectively; and

if an external power supply was used to test the battery charger, the power supply’s model number and the name of its manufacturer.

Line Voltage Thermostats

s. 594 — Definitions

The following definitions apply in this Subdivision.

control point means the temperature value, measured at the centre of the test room, that is used to verify the performance of a line voltage thermostat at the set point. (température de contrôle)

CSA C828-19 means the CSA standard CSA C828:19 entitled Performance requirements for line voltage thermostats used with individual room electric space heating devices. (CSA C828-19)

differential means the difference between the maximum and minimum air temperatures at the centre of the test room, calculated at 50% duty cycle. (différentielle)

droop means the difference between the minimum air temperatures at the centre of the test room, calculated at 20% and 80% duty cycle, respectively. (dérive)

line voltage thermostat means, subject to subsection (2), a thermostat that is used with a line voltage of between 120 V and 240 V, is intended for switching of a controlled resistive heating load and is one of the following:

a wall-mounted thermostat designed to be used with baseboards, panel convectors or radiant floors;

a built-in thermostat having a nominal load from 1000 W to 1500 W that is used in baseboards or panel convectors; or

a two-component thermostat. (thermostat à tension de secteur)

s. 594(2) — Exclusion — definition of line voltage thermostat

The definition line voltage thermostat in subsection (1) does not include thermostats designed to be used exclusively for or built into

fan-forced heaters;

kick space heaters;

fireplaces;

thermal storage heaters;

electric baseboards and convectors incorporating both convection and radiant heating elements;

portable heaters; or

central heating units under the control of a single thermostat.

s. 595 — Energy-using product

A line voltage thermostat is prescribed as an energy-using product.

s. 595(2) — Limit

However, for the purposes of sections 4, 5, 596 and 597, a line voltage thermostat is not considered to be an energy-using product unless

in the case of a wall-mounted thermostat or a two-component thermostat, it is manufactured on or after July 1, 2026; and

in the case of a built-in thermostat, it is manufactured on or after July 1, 2027.

s. 596 — Energy efficiency standards

The energy efficiency standards set out in clause 4.4 of CSA C828-19 apply to a line voltage thermostat.

s. 596(2) — Testing standard

A line voltage thermostat complies with the energy efficiency standard when tested in accordance with the applicable testing procedures established by CSA C828-19.

s. 597 — Information

For the purpose of subsection 5(1) of the Act, the following information must be collected in accordance with CSA C828-19 and provided to the Minister in respect of a line voltage thermostat:

its equipment class;

its nominal voltage;

its maximum nominal load, expressed in watts;

its minimum nominal load, expressed in watts;

its droop, expressed in degrees Celsius;

its differential, expressed in degrees Celsius; and

its control point precision, expressed in degrees Celsius.

Commercial Refrigeration

Interpretation

s. 635 — Definition of Edaily

In this Division, E daily means the daily energy consumption of a product, expressed in kilowatt hours per day.

Commercial Refrigerators, Refrigerator-Freezers and Freezers

s. 636 — Definitions

The following definitions apply in this Subdivision.

AV means, in respect of a commercial refrigerator-freezer, its adjusted volume in litres, which is the sum of the refrigerator volume and 1.63 times the freezer volume. (VC)

closed means

in respect of a refrigerated compartment of a commercial refrigerator, commercial refrigerator-freezer or commercial freezer, that all its points of access can be closed off from the outside by a physical barrier and from which any refrigerated item can be accessed by opening a door or drawer; and

in respect of a commercial refrigerator, commercial refrigerator-freezer or commercial freezer, that all of its compartments are as described in paragraph (a). (type fermé)

commercial freezer means a freezer that is self-contained or remote-condensing, that uses or is designed to be used with a vapour-compression refrigeration system and whose compartments are all designed for the freezing and display or storage of food, beverages or ice at temperatures below 0°C. It does not include a household freezer or walk-in freezer. (congélateur commercial)

commercial refrigerator means a refrigerator that is self-contained or remote-condensing, that uses or is designed to be used with a vapour-compression refrigeration system and whose compartments are all designed for the display or storage of food, beverages or flowers at temperatures at or above 0°C. It does not include a household refrigerator, refrigerated buffet table, refrigerated preparation table or walk-in cooler. (réfrigérateur commercial)

commercial refrigerator-freezer means a refrigerator-freezer that is self-contained or remote-condensing, that uses or is designed to be used with a vapour-compression refrigeration system and that has two or more compartments, at least one of which is designed for the display or storage of food and beverages at temperatures at or above 0°C and at least one of which is designed for the freezing and display or storage of food and beverages at temperatures below 0°C. It does not include a household refrigerator-freezer, walk-in freezer or walk-in cooler. (réfrigérateur-congélateur commercial)

CSA C657 means the CSA standard CSA C657-2015 entitled Energy Performance Standard for Commercial Refrigeration Equipment. (CSA C657)

ice cream freezer means a commercial freezer that is designed to operate at temperatures at or below –21°C ± 1.1°C and that is designed or marketed for the storage, display or dispensing of ice cream. (congélateur de crème glacée)

open means, in respect of a commercial refrigerator, commercial refrigerator-freezer or commercial freezer — or a refrigerated compartment of one — that it is not closed. (type ouvert)

pull-down temperature reduction capability means the capability of a commercial refrigerator, when it is situated in an area that has an ambient temperature of 32.22˚C and when it is fully loaded with 355 mL beverage cans that are at a temperature of 32.22˚C at the time of loading, to cool those cans to an average stable temperature of 3.33˚C in 12 hours or less. (capacité d’abaisser la température)

TDA means the total display area of a product, expressed in square metres. (TDA)

transparent means

in respect of a refrigerated compartment of a commercial refrigerator, commercial refrigerator-freezer or commercial freezer, that it is closed and has a TDA that is at least 75% of the geometrically projected area of the refrigerated space on the plane of the face with the largest access space; and

in respect of a commercial refrigerator, commercial refrigerator-freezer or commercial freezer, that all of its compartments are as described in paragraph (a). (transparent)

V means, in respect of a refrigerated compartment of a commercial refrigerator, commercial refrigerator-freezer or commercial freezer, its volume, expressed in litres, calculated in accordance with clause 8 of CSA C657. (V)

Commercial Refrigerators

s. 637 — Energy-using product

A commercial refrigerator is prescribed as an energy-using product.

s. 637(2) — Limits

However, a commercial refrigerator is not considered to be an energy-using product

for the purposes of sections 4 and 5, unless

it is self-contained and manufactured on or after April 1, 2007, or

it is remote-condensing and manufactured on or after January 1, 2012; and

for the purpose of section 638, unless

it is self-contained, closed and was manufactured on or after April 1, 2007 and before January 1, 2012, or

it is manufactured on or after January 1, 2012.

s. 638 — Energy efficiency standards

The energy efficiency standards set out in column 3 of the table to this section apply to commercial refrigerators described in column 1 that are manufactured during the periods set out in column 4.

s. 638(2) — Testing standard

A commercial refrigerator complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by the standard set out in column 2 that are applicable to a commercial refrigerator as defined in section 636. TABLE Column 1 Column 2 Column 3 Column 4 Item Energy-using Product Testing Standard Energy Efficiency Standard Period of Manufacture 1 Commercial refrigerators that are self-contained, closed and not transparent CSA C657, Test Procedure A E daily ≤ 0.00441 V + 4.22 On or after April 1, 2007 and before January 1, 2008 2 Commercial refrigerators that are self-contained, closed and not transparent CSA C657, Test Procedure A E daily ≤ 0.00441 V + 2.76 On or after January 1, 2008 and before January 1, 2010 3 Commercial refrigerators that are self-contained, closed and not transparent CSA C657, Test Procedure A E daily ≤ 0.00353 V + 2.04 On or after January 1, 2010 and before March 27, 2017 4 Commercial refrigerators that are self-contained and transparent CSA C657, Test Procedure A E daily ≤ 0.00607 V + 5.78 On or after April 1, 2007 and before January 1, 2008 5 Commercial refrigerators that are self-contained and transparent CSA C657, Test Procedure A E daily ≤ 0.00607 V + 4.77 On or after January 1, 2008 and before January 1, 2010 6 Commercial refrigerators that are self-contained and transparent and that do not have pull-down temperature reduction capability CSA C657, Test Procedure A E daily ≤ 0.00424 V + 3.34 On or after January 1, 2010 and before March 27, 2017 7 Commercial refrigerators that are self-contained and transparent and that have pull-down temperature reduction capability CSA C657, Test Procedure A E daily ≤ 0.00445 V + 3.51 On or after January 1, 2010 and before March 27, 2017 8 Commercial refrigerators that are self-contained and open CSA C657, Test Procedure A CSA C657, Table 5 On or after January 1, 2012 and before March 27, 2017 9 Commercial refrigerators that are remote-condensing CSA C657, Test Procedure A CSA C657, Table 5 On or after January 1, 2012 and before March 27, 2017 10 Commercial refrigerators CSA C657, Test Procedure B CSA C657, Table 6 On or after March 27, 2017

s. 639 — Information

For the purpose of subsection 5(1) of the Act, the following information must be provided to the Minister in respect of a commercial refrigerator:

its E daily;

for each of its compartments,

its equipment class designation and its TDA or V, as applicable, and

if it is tested at its lowest temperature setting, the integrated average temperature, expressed in degrees Celsius, at the lowest temperature setting.

s. 639(2) — Standards

The information must be collected in accordance with one of the following standards:

CSA C657, Test Procedure A, if the product was manufactured before March 27, 2017; or

CSA C657, Test Procedure B, if the product is manufactured on or after March 27, 2017.

Commercial Refrigerator-Freezers

s. 640 — Energy-using product

A commercial refrigerator-freezer is prescribed as an energy-using product.

s. 640(2) — Limits

However, a commercial refrigerator-freezer is not considered to be an energy-using product

for the purposes of sections 4 and 5, unless

it is self-contained, is closed and is manufactured on or after April 1, 2007,

it is self-contained, is open and is manufactured on or after January 1, 2012, or

it is remote-condensing and is manufactured on or after January 1, 2012; and

for the purpose of section 641, unless

it is self-contained, is closed, is not transparent and is manufactured on or after April 1, 2007,

it is self-contained, is open or transparent and is manufactured on or after January 1, 2012, or

it is remote-condensing and is manufactured on or after January 1, 2012.

s. 641 — Energy efficiency standards

The energy efficiency standards set out in column 3 of the table to this section apply to commercial refrigerator-freezers described in column 1 that are manufactured during the periods set out in column 4.

s. 641(2) — Testing standard

A commercial refrigerator-freezer complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by the standard set out in column 2 that are applicable to a commercial refrigerator-freezer as defined in section 636. TABLE Column 1 Column 2 Column 3 Column 4 Item Energy-using Product Testing Standard Energy Efficiency Standard Period of Manufacture 1 Commercial refrigerator-freezers that are self-contained, closed and not transparent CSA C657, Test Procedure A E daily ≤ 0.00964 AV + 2.63 On or after April 1, 2007 and before January 1, 2008 2 Commercial refrigerator-freezers that are self-contained, closed and not transparent CSA C657, Test Procedure A E daily ≤ 0.00964 AV + 1.65 On or after January 1, 2008 and before January 1, 2010 3 Commercial refrigerator-freezers that are self-contained, closed and not transparent CSA C657, Test Procedure A E daily ≤ the greater of (0.00953 AV – 0.71) and 0.70 On or after January 1, 2010 and before March 27, 2017 4 Commercial refrigerator-freezers that are self-contained and open or transparent CSA C657, Test Procedure A CSA C657, Table 5 On or after January 1, 2012 and before March 27, 2017 5 Commercial refrigerator-freezers that are remote-condensing CSA C657, Test Procedure A CSA C657, Table 5 On or after January 1, 2012 and before March 27, 2017 6 Commercial refrigerator-freezers CSA C657, Test Procedure B CSA C657, Table 6 On or after March 27, 2017

s. 642 — Information

For the purpose of subsection 5(1) of the Act, the information set out in column 3 of the table to this section must be collected in accordance with the standard set out in column 2 and provided to the Minister in respect of a commercial refrigerator-freezer described in column 1. TABLE Column 1 Column 2 Column 3 Item Energy-using Product Testing Standard Information 1 Commercial refrigerator-freezers that are self-contained, closed, not transparent and manufactured on or after April 1, 2007 and before March 27, 2017 CSA C657, Test Procedure A 2 Commercial refrigerator-freezers that are self-contained, transparent and manufactured on or after April 1, 2007 and before January 1, 2012 CSA C657, Test Procedure A 3 Commercial refrigerator-freezers that are self-contained, open or transparent and manufactured on or after January 1, 2012 and before March 27, 2017 CSA C657, Test Procedure A 4 Commercial refrigerator-freezers that are remote-condensing and manufactured on or after January 1, 2012 and before March 27, 2017 CSA C657, Test Procedure A 5 Commercial refrigerator-freezers that are manufactured on or after March 27, 2017 CSA C657, Test Procedure B

Commercial Freezers

s. 643 — Energy-using product

A commercial freezer is prescribed as an energy-using product.

s. 643(2) — Limits

However, a commercial freezer is not considered to be an energy-using product

for the purposes of sections 4 and 5, unless

it is self-contained and manufactured on or after April 1, 2007, or

it is remote-condensing and is manufactured on or after January 1, 2012; and

for the purpose of section 644, unless

it is self-contained, closed and was manufactured on or after April 1, 2007 and before January 1, 2012, or

it is manufactured on or after January 1, 2012.

s. 644 — Energy efficiency standards

The energy efficiency standards set out in column 3 of the table to this section apply to commercial freezers described in column 1 that are manufactured during the periods set out in column 4.

s. 644(2) — Testing standard

A commercial freezer complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by the standard set out in column 2 that are applicable to a commercial freezer as defined in section 636. TABLE Column 1 Column 2 Column 3 Column 4 Item Energy-using Product Testing Standard Energy Efficiency Standard Period of Manufacture 1 Commercial freezers that are self-contained and open, other than ice cream freezers CSA C657, Test Procedure A CSA C657, Table 5 On or after January 1, 2012 and before March 27, 2017 2 Commercial freezers that are self-contained, closed and not transparent and have a volume of < 340 L CSA C657, Test Procedure A E daily ≤ 7.62 On or after April 1, 2007 and before January 1, 2008 3 Commercial freezers that are self-contained, closed and not transparent and have a volume of < 340 L CSA C657, Test Procedure A E daily ≤ 7.07 On or after January 1, 2008 and before January 1, 2010 4 Commercial freezers that are self-contained, closed and not transparent and have a volume of ≥ 340 L CSA C657, Test Procedure A E daily ≤ 0.0141 V + 2.83 On or after April 1, 2007 and before January 1, 2008 5 Commercial freezers that are self-contained, closed and not transparent and have a volume of ≥ 340 L CSA C657, Test Procedure A E daily ≤ 0.0141 V + 2.28 On or after January 1, 2008 and before January 1, 2010 6 Commercial freezers that are self-contained, closed and not transparent CSA C657, Test Procedure A E daily ≤ 0.01413 V + 1.38 On or after January 1, 2010 and before January 1, 2012 7 Commercial freezers that are self-contained, closed and not transparent, other than ice cream freezers CSA C657, Test Procedure A E daily ≤ 0.01413 V + 1.38 On or after January 1, 2012 and before March 27, 2017 8 Commercial freezers that are self-contained and transparent CSA C657, Test Procedure A E daily ≤ 0.0332 V + 5.10 On or after April 1, 2007 and before January 1, 2010 9 Commercial freezers that are self-contained and transparent CSA C657, Test Procedure A E daily ≤ 0.02649 V + 4.10 On or after January 1, 2010 and before January 1, 2012 10 Commercial freezers that are self-contained and transparent, other than ice cream freezers CSA C657, Test Procedure A E daily ≤ 0.02649 V + 4.10 On or after January 1, 2012 and before March 27, 2017 11 Commercial freezers that are remote-condensing, other than ice cream freezers CSA C657, Test Procedure A CSA C657, Table 5 On or after January 1, 2012 and before March 27, 2017 12 Ice cream freezers CSA C657, Test Procedure A CSA C657, Table 5 On or after January 1, 2012 and before March 27, 2017 13 Commercial freezers CSA C657, Test Procedure B CSA C657, Table 6 On or after March 27, 2017

s. 645 — Information

For the purpose of subsection 5(1) of the Act, the following information must be provided to the Minister in respect of a commercial freezer:

its E daily; and

for each of its compartments,

its equipment class designation and its TDA or V, as applicable, and

if it is tested at its lowest temperature setting, the integrated average temperature, expressed in degrees Celsius, at the lowest temperature setting.

s. 645(2) — Standards

The information must be collected in accordance with one of the following standards:

CSA C657, Test Procedure A, if the product was manufactured before March 27, 2017; or

CSA C657, Test Procedure B, if the product is manufactured on or after March 27, 2017.

Refrigerated Vending Machines

s. 646 — Definitions

The following definitions apply in this Subdivision.

ASHRAE 32.1 means the ASHRAE standard 32.1-2010 entitled Methods of Testing for Rating Vending Machines for Bottled, Canned, and Other Sealed Beverages. (ASHRAE 32.1)

combination vending machine means a refrigerated beverage vending machine containing two or more compartments separated by a solid partition — whether or not they share a product delivery chute — in which at least one compartment is designed to be refrigerated and has temperature controls; and at least one compartment is not designed to be refrigerated and does not contain temperature controls. (distributeur automatique mixte))

CSA C804 means the CSA standard CAN/CSA-C804:18 entitled Energy performance of refrigerated bottled or canned beverage vending machines. (CSA C804)

refrigerated beverage vending machine means a self-contained product that is designed to accept consumer payments and dispense refrigerated beverages in bottles, cans or other sealed containers. (distributeur automatique de boissons réfrigérées)

snack and refrigerated beverage vending machine means a self-contained product that

is designed to accept consumer payments and dispense packages of solid non-refrigerated food and bottled, canned or other sealed refrigerated beverages; and

has a vendible capacity of not more than 100 of those beverages. (distributeur automatique de boissons réfrigérées et de collations)

standby mode means a mode into which the product automatically enters during a period of extended inactivity that is capable of reducing its energy consumption by means of the following power states:

a refrigeration power state in which the average temperature of the refrigerated beverages is allowed to rise to 4.4°C; and

if the product is equipped with lights,

a lighting power state in which the lights are turned off, and

a machine power state in which the power states referred in paragraph (a) and subparagraph (i) are in operation at the same time. (mode veille)

V means, in respect of a refrigerated beverage vending machine, its volume, expressed in litres, calculated in accordance with Appendix C to ASHRAE 32.1. (V)

Refrigerated Beverage Vending Machines

For the purposes of these Regulations, the class of a refrigerated beverage vending machine is one of the following:

Class A, if it is not a combination vending machine and 25% or more of the surface area on the front side of the refrigerated beverage vending machine is transparent;

Class B, if it is not a combination vending machine and less than 25% of the surface area on the front side of the refrigerated beverage vending machine is transparent;

Combination A, if it is a combination vending machine and 25% or more of the surface area on its front side is transparent; and

Combination B, if it is a combination vending machine and less than 25% of the surface area on its front side is transparent.

s. 647 — Energy-using product

A refrigerated beverage vending machine is prescribed as an energy-using product.

s. 647(2) — Limit

However, for the purposes of sections 4, 5 and 648, a refrigerated beverage vending machine is not considered to be an energy-using product unless it is manufactured on or after January 1, 2007.

s. 648 — Energy efficiency standards

The energy efficiency standards set out in column 2 of the table to this section apply to refrigerated beverage vending machines described in column 1 that are manufactured during the periods set out in column 3.

s. 648(2) — Testing standard

The refrigerated beverage vending machine complies with the energy efficiency standard if it meets that standard in the following circumstances: TABLE Column 1 Column 2 Column 3 Item Energy-using Product Energy Efficiency Standard Period of Manufacture 1 Refrigerated beverage vending machines, other than those that display and dispense 20 or more discrete types of beverages On or after January 1, 2007 and before January 1, 2008 2 Refrigerated beverage vending machines, other than those that display and dispense 20 or more discrete types of beverages On or after January 1, 2008 and before August 31, 2012 3 Refrigerated beverage vending machines that display and dispense 20 or more discrete types of beverages On or after January 1, 2007 and before August 31, 2012 4 Class A refrigerated beverage vending machines On or after August 31, 2012 and before January 8, 2019 5 Class B refrigerated beverage vending machines On or after August 31, 2012 and before January 8, 2019 6 Class A refrigerated beverage vending machines E daily ≤ 0.00184 x V + 2.43 On or after January 8, 2019 7 Class B refrigerated beverage vending machines E daily ≤ 0.00184 x V + 2.20 On or after January 8, 2019 8 Combination A combination vending machines E daily ≤ 0.00304 x V + 2.66 On or after January 8, 2019 9 Combination B combination vending machines E daily ≤ 0.00392 x V + 2.04 On or after January 8, 2019

subject to paragraph (b), it is manufactured before January 8, 2019 and tested in accordance with testing procedures established by sections 1 to 7.2 of ASHRAE 32.1 that are applicable to a refrigerated beverage vending machine as defined in section 646, except that the ambient temperature during the testing to determine E daily must be 23.9°C ± 1°C;

it is manufactured before August 31, 2012, is designed to display and dispense less than 20 discrete types of beverages and is tested in accordance with testing procedures established by sections 1 to 7.2 of ASHRAE 32.1 that are applicable to a refrigerated beverage vending machine as defined in section 646, except that the ambient temperature during the testing to determine the E daily must be 32.2°C ± 1°C; or

it is manufactured on or after January 8, 2019 and tested in accordance with testing procedures established by CSA C804.

s. 649 — Information

For the purpose of subsection 5(1) of the Act, the information set out in column 3 of the table to this section must be collected in accordance with the standard set out in column 2, with the testing procedure adjusted in accordance with paragraphs 648(2)(a) and (b), and be provided to the Minister in respect of a refrigerated beverage vending machine described in column 1. TABLE Item Column 1 Column 2 Column 3 Energy-using Product Testing Standard Information 1 Refrigerated beverage vending machines manufactured on or after January 1, 2007 and before August 31, 2012 Sections 1 to 7.2 of ASHRAE 32.1 2 Refrigerated beverage vending machines manufactured on or after August 31, 2012 and before January 8, 2019 Sections 1 to 7.2 of ASHRAE 32.1 3 Refrigerated beverage vending machines manufactured on or after January 8, 2019 CSA C804

Snack and Refrigerated Beverage Vending Machines

s. 650 — Energy-using product

A snack and refrigerated beverage vending machine is prescribed as an energy-using product.

s. 650(2) — Limit

However, for the purposes of sections 4, 5 and 651, a snack and refrigerated beverage vending machine is not considered to be an energy-using product unless it is manufactured on or after January 1, 2007 and before January 8, 2019.

s. 651 — Energy efficiency standards

The following energy efficiency standards apply to a snack and refrigerated beverage vending machine:

its E daily must be less than or equal to 55% (8.66 + 0.009 × vendible capacity); and

it must be capable of operating in standby mode.

s. 651(2) — Testing standard

A snack and refrigerated beverage vending machine complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by sections 1 to 7.2 of ASHRAE 32.1 that are applicable to a snack and refrigerated beverage vending machine as defined in section 646, except that the ambient temperature during the testing to determine E daily must be 23.9°C ± 1°C.

s. 652 — Information

For the purpose of subsection 5(1) of the Act, the following information must be collected in accordance with ASHRAE 32.1, with the testing procedures adjusted in accordance with subsection 651(2), and be provided to the Minister in respect of a snack and refrigerated beverage vending machine:

its E daily; and

its vendible capacity.

Ice-Makers

s. 653 — Definitions

The following definitions apply in this Subdivision.

CSA C742-08 means the CSA standard CAN/CSA-C742-08 entitled Energy Performance of Automatic Icemakers and Ice Storage Bins. (CSA C742-08)

CSA C742-15 means the CSA standard CAN/CSA-C742-15 entitled Energy Performance of Automatic Icemakers and Ice Storage Bins. (CSA C742-15)

CSA C742-98 means the CSA standard CAN/CSA-C742-98 entitled Performance of Automatic Ice-Makers and Ice Storage Bins. (CSA C742-98)

ice-maker means a factory-assembled automatic ice-maker that has a capacity of at least 23 kg/day (51 pounds per day) but not more than 1 814 kg/day (4,000 pounds per day) and that produces cubed, flaked, crushed or fragmented ice in either a batch or a continuous process. (machine à glaçons)

10 C.F.R. §431.134 means section 431.134 of Subpart H, Part 431 of Title 10 to the United States Code of Federal Regulations, as amended from time to time. (10 C.F.R. §431.134)

s. 654 — Energy-using product

An ice-maker is prescribed as an energy-using product.

s. 654(2) — Limit

However, for the purposes of sections 4, 5 and 655, an ice-maker is not considered to be an energy-using product unless

it is manufactured on or after December 31, 1998 and before January 28, 2018 and has a capacity of not more than 1 000 kg/day (2,200 pounds per day); or

it is manufactured on or after January 28, 2018 and has a capacity of not more than 1 814 kg/day (4,000 pounds per day).

s. 655 — Energy efficiency standards

The energy efficiency standards set out in column 3 of the table to this section apply to ice-makers described in column 1 that are manufactured during the periods set out in column 4.

s. 655(2) — Testing standard

An ice-maker complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by the standard set out in column 2 that are applicable to an ice-maker as defined in section 653. TABLE Column 1 Column 2 Column 3 Column 4 Item Energy-using Product Testing Standard Energy Efficiency Standard Period of Manufacture 1 Ice-makers that have a capacity of ≥ 23 kg/day (51 lbs/day) but ≤ 1 000 kg/day (2,200 lbs/day) CSA C742-98 CSA C742-98, Table 2 On or after December 31, 1998 and before January 1, 2008 2 Ice-makers that have a capacity of ≥ 23 kg/day (51 lbs/day) but ≤ 1 000 kg/day (2,200 lbs/day) and that produce ice in a continuous process CSA C742-98 CSA C742-98, Table 2, categories “Continuous automatic ice-makers” and “Ice storage bins”On or after January 1, 2008 and before January 28, 2018 3 Ice-makers that have a capacity of ≥ 23 kg/day (51 lbs/day) but ≤ 1 000 kg/day (2,200 lbs/day) and that produce ice in a batch process CSA C742-08 CSA C742-08, Tables 2 and 3 On or after January 1, 2008 and before January 28, 2018 4 Ice-makers CSA C742-15 or 10 C.F.R. §431.134 CSA C742-15, Tables 3 to 5 On or after January 28, 2018

s. 656 — Information

For the purpose of subsection 5(1) of the Act, the information set out in column 3 of the table to this section must be collected in accordance with the standard set out in column 2 and provided to the Minister in respect of an ice-maker described in column 1. TABLE Column 1 Column 2 Column 3 Item Energy-using Product Testing Standard Information 1 Ice-makers manufactured on or after December 31, 1998 and before January 1, 2008 CSA C742-98 2 Ice-makers manufactured on or after January 1, 2008 and before January 28, 2018 3 Ice-makers manufactured on or after January 28, 2018 CSA C742-15

Walk-in Freezer and Walk-in Cooler Components

Interpretation

s. 657 — Definitions

The following definitions apply in this Subdivision.

A dd represents, with respect to display door assemblies, the surface area in m 2 (square feet). (A pp)

A nd represents, with respect to a door assembly other than a display door assembly, the surface area in m 2 (square feet). (A pa)

annual walk-in energy factor means the ratio of total heat removed from an enclosed space, excluding heat generated by the operation of the walk-in refrigeration system, to the total energy input of the walk-in refrigeration system during a one-year period, expressed in watt-hours per watt-hours. (facteur énergétique annuel de la chambre froide)

dedicated condensing refrigeration system means a dedicated condensing unit, a single-package dedicated system or a matched refrigeration system. (unité de condensation dédié)

dedicated condensing unit means a positive displacement condensing unit that

has one or more compressors, a condenser and one refrigeration circuit; and

is designed to serve one refrigerated load. (unité de condensation dédiée)

[Repealed]

display door assembly means a walk-in door assembly that is designed for product display and that has 75% or more of its surface area composed of glass or other transparent material. (assemblage de porte de présentation)

envelope means

the portion of a walk-in cooler or walk-in freezer that isolates the interior, refrigerated environment from the ambient, external environment; and

all energy-consuming components of the walk-in cooler or walk-in freezer that are not part of its refrigeration system. (enveloppe)

floor panel means a walk-in panel that is installed, or designed to be installed, as the floor of a walk-in freezer. (panneau de plancher)

freight door assembly means a walk-in door assembly, other than a display door assembly, that is 1.22 m (4 feet) or more in width and 2.44 m (8 feet) or more in height. (assemblage de porte de quai de chargement)

matched refrigeration system means a refrigeration system that includes a dedicated condensing unit and one or more unit coolers with which it is sold. (système de réfrigération apparié)

Net Refrigeration Capacity or (q net) is the net refrigeration capacity available for space and product cooling. (puissance frigorifique nette ou q net)

passage door assembly means a walk-in door assembly that is not a display door assembly or a freight door assembly. (assemblage de porte de passage)

RSI-value means, in respect of a walk-in panel and a walk-in door assembly, its thermal resistance, in square metre kelvins per watt (m²·K/W). (valeur-RSI)

R-value means, in respect of a walk-in panel and a walk-in door assembly, its thermal resistance, expressed in square foot Fahrenheit per Btu/h (ft 2·°F·h/Btu). (valeur-R)

single-package dedicated system means a single-package refrigeration system that has

one or more compressors, one condenser and a means of forced circulation of refrigerated air; and

components by which heat is transferred from air to refrigerant without any components that are external to the system imposing resistance to the flow of the refrigerated air. (système dédié monobloc)

structural panel means a walk-in panel that is installed, or is designed to be installed, as the ceiling or a wall of a walk-in cooler or walk-in freezer. (panneau de structure)

10 C.F.R. Appendix A means Appendix A to Subpart R, Part 431 of Title 10 to the United States Code of Federal Regulations, entitled Uniform Test Method for the Measurement of Energy Consumption of the Components of Envelopes of Walk-In Coolers and Walk-In Freezers, as amended from time to time. (appendice A 10 C.F.R.)

10 C.F.R. Appendix B means Appendix B to Subpart R, Part 431 of Title 10 to the United States Code of Federal Regulations, entitled Uniform Test Method for the Measurement of R-Value for Envelope Components of Walk-In Coolers and Walk-In Freezers, as amended from time to time. (appendice B 10 C.F.R.)

10 C.F.R. Appendix C means Appendix C to Subpart R, Part 431 of Title 10 to the United States Code of Federal Regulations, entitled Uniform Test Method for the Measurement of Net Capacity and AWEF of Walk-In Cooler and Walk-In Freezer Refrigeration Systems, as amended from time to time. (appendice C 10 C.F.R.)

10 C.F.R. §431.304 means section 431.304 of Subpart R, Part 431 of Title 10 to the United States Code of Federal Regulations, as amended from time to time. (10 C.F.R. §431.304)

unit cooler means an assembly that includes a means for forced air circulation and elements by which heat is transferred from air to refrigerant without any element external to the cooler imposing air resistance. (refroidisseur d’air)

walk-in cooler means an enclosed storage space that has an area of less than 278.71 m 2 (3,000 square feet) and is designed to be cooled to temperatures at or above 0°C and to allow a person to enter, but does not include a walk-in cooler that is designed and marketed exclusively for medical, scientific or research purposes. (réfrigérateur-chambre)

walk-in door assembly means an assembly that is installed, or is designed to be installed, in an opening of an interior or exterior wall of a walk-in cooler or walk-in freezer in order to allow access through the opening or to close it off and that consists of the framing material necessary for its attachment and a moveable door panel, including any glass, door plugs or mullions, but does not include a walk-in door assembly that is designed and marketed exclusively for medical, scientific or research purposes. (assemblage de porte de chambre froide)

walk-in freezer means an enclosed storage space that has an area of less than 278.71 m 2 (3000 square feet) and is designed to be cooled to temperatures below 0°C and to allow a person to enter, but does not include a walk-in freezer that is designed and marketed exclusively for medical, scientific or research purposes. (congélateur-chambre)

walk-in panel means a panel that is installed, or is designed to be installed, as part of the envelope of a walk-in cooler or walk-in freezer, but does not include a walk-in door assembly or a walk-in panel that is designed and marketed exclusively for medical, scientific or research purposes. (panneau de chambre froide)

walk-in process cooling refrigeration system means a refrigeration system that

is sold as a set with an insulated enclosure and, when assembled with the enclosure, has a cooling capacity of at least 1.035 kW/m 3 (100 Btu/h/ft 3) of enclosed internal volume;

is a unit cooler — or a dedicated condensing unit exclusively sold as a set that has a dedicated condensing unit and a unit cooler — that has an evaporator coil with a means of forced air circulation and a height that is

at least 1.37 metres (4.5 feet), as measured perpendicular to the tubes, and

at least one and a half times the width, as measured parallel to the tubes; or

is sold as a set that has a dedicated condensing unit and an evaporator coil that does not have a means of forced air circulation. (système de réfrigération de type chambre pour refroidissement industriel)

walk-in refrigeration system means a refrigeration system that is installed, or that is designed to be installed, in a walk-in cooler or walk-in freezer and has a unit cooler or a dedicated condensing refrigeration system. It includes all controls and other components that are integral to its operation but does not include a walk-in process cooling refrigeration system or a walk-in refrigeration system that is designed and marketed exclusively for medical, scientific or research purposes. (système de réfrigération de chambre froide)

Nameplate

s. 658 — Nameplate required

Every walk-in door assembly and walk-in panel that is manufactured on or after June 26, 2017 must be labelled with a nameplate that is attached to the outside of the product in a location that is readily visible prior to assembly of the walk-in cooler or walk-in freezer and that sets out the following information in English and French:

the brand name or manufacturer of the product; and

a statement indicating whether the product is intended for use in a walk-in cooler, walk-in freezer or both.

s. 658(2) — Additional requirements

Every walk-in cooler dedicated condensing refrigeration system that is manufactured on or after January 1, 2020 and every walk-in refrigeration system that is manufactured on or after July 10, 2020 must be labelled with a nameplate that is attached to the outside of the product in a location that is readily visible prior to assembly of the walk-in cooler or the walk-in freezer and that sets out the following information in English and French:

the brand name or manufacturer of the product;

a statement indicating whether the product is intended for use in a walk-in cooler, walk-in freezer or both;

the model number;

the product’s date of manufacture, if it is not included in the model number; and

a statement indicating that the product is for indoor use only, if applicable.

s. 658(3) — Idem

For matched refrigeration systems, the statement referred to in paragraph (2)(e) must appear on the dedicated condensing unit.

Walk-in Door Assemblies

s. 659 — Energy-using product

A walk-in door assembly is prescribed as an energy-using product.

s. 659(2) — Limit

However, for the purposes of sections 4, 5 and 660, a walk-in door assembly is not considered to be an energy-using product unless it is manufactured on or after June 5, 2017.

s. 660 — Energy efficiency standards

The energy efficiency standards set out in column 3 of the table to this section apply to walk-in door assemblies described in column 1 that are manufactured on or after June 5, 2017.

s. 660(2) — Testing standard

A walk-in door assembly complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by the standard set out in column 2 that are applicable to a walk-in door assembly as defined in section 657. TABLE Column 1 Column 2 Column 3 Item Energy-using Product Testing Standard Energy Efficiency Standard 1 Display door assemblies for walk-in coolers 10 C.F.R. Appendix A E daily ≤ 0.4306 × A dd + 0.41 (0.04 × A dd+ 0.41) 2 Display door assemblies for walk-in freezers 10 C.F.R. Appendix A E daily ≤ 1.6146 × A dd + 0.29 (0.15 × A dd+ 0.29) 3 Freight door assemblies for walk-in coolers 4 Freight door assemblies for walk-in freezers 5 Passage door assemblies for walk-in coolers 6 Passage door assemblies for walk-in freezers

s. 661 — Information

For the purpose of subsection 5(1) of the Act, the following information must be collected in accordance with 10 C.F.R. §431.304 and provided to the Minister in respect of a walk-in door assembly:

its E daily;

information that indicates whether it is a display door assembly, freight door assembly or passage door assembly;

information that indicates whether it is for use with a walk-in cooler or walk-in freezer; and

if the product is a freight door assembly or passage door assembly, its RSI-value (R-value).

Walk-in Panels

s. 662 — Energy-using product

A walk-in panel is prescribed as an energy-using product.

s. 662(2) — Limit

However, for the purposes of sections 4, 5 and 663, a walk-in panel is not considered to be an energy-using product unless it is manufactured on or after June 5, 2017.

s. 663 — Energy efficiency standards

The energy efficiency standards set out in column 2 of the table to this section apply to walk-in panels described in column 1 that are manufactured on or after June 5, 2017.

s. 663(2) — Testing standard

A walk-in panel complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by 10 C.F.R. Appendix B that are applicable to a walk-in panel as defined in section 657. TABLE Column 1 Column 2 Item Energy-using Product Energy Efficiency Standard 1 Structural panels for walk-in coolers RSI-value ≥ 4.40 m²·K/W (25 ft²·°F h/Btu) 2 Structural panels for walk-in freezers RSI-value ≥ 5.64 m²·K/W (32 ft²·°F h/Btu) 3 Floor panels RSI-value ≥ 4.93 m²·K/W (28 ft²·°F h/Btu)

s. 664 — Information

For the purpose of subsection 5(1) of the Act, the following information must be collected in accordance with 10 C.F.R. Appendix B and provided to the Minister in respect of a walk-in panel:

its RSI-value (R-value),

information that indicates whether it is a structural panel or floor panel; and

if it is a structural panel, information that indicates whether it is for use with a walk-in cooler or walk-in freezer.

Walk-in Refrigeration Systems

s. 665 — Energy-using product

A walk-in refrigeration system is prescribed as an energy-using product.

s. 665(2) — Limit

However, a walk-in refrigeration system is not considered to be an energy-using product for the purposes of sections 4, 5 and 666 unless

it is a walk-in cooler dedicated condensing refrigeration system manufactured on or after January 1, 2020;

it is a walk-in freezer dedicated condensing refrigeration system manufactured on or after July 10, 2020; or

it is a walk-in cooler or walk-in freezer unit cooler manufactured on or after July 10, 2020.

s. 666 — Energy efficiency standards

The energy efficiency standards set out in column 2 of the table to this section apply to walk-in refrigeration systems described in column 1 that are manufactured during the periods set out in column 3.

s. 666(2) — Testing standard

A walk-in refrigeration system complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by 10 C.F.R. Appendix C that are applicable to a walk-in refrigeration system as defined in section 657. TABLE Item Column 1 Column 2 Column 3 Energy-using Product Energy Efficiency Standard Period of Manufacture 1 Walk-in cooler dedicated condensing refrigeration systems for use indoors Annual walk-in energy factor ≥ 1.644 W-h/W-h (5.61 Btu/W-h) On or after January 1, 2020 2 Walk-in cooler dedicated condensing refrigeration systems for use outdoors Annual walk-in energy factor ≥ 2.227 W-h/W-h (7.60 Btu/W-h) On or after January 1, 2020 3 Walk-in freezer dedicated condensing refrigeration systems for use indoors with a net refrigeration capacity of < 1900 W (6,500 Btu/h) Annual walk-in energy factor ≥ 9.091 x 10-5 x q net + 0.530 W-h/W-h (9.091 x 10-5 x q net+ 1.81 Btu/W-h) On or after July 10, 2020 4 Walk-in freezer dedicated condensing refrigeration systems for use indoors with a net refrigeration capacity of ≥ 1900 W (6,500 Btu/h) Annual walk-in energy factor ≥ 0.703 W-h/W-h (2.40 Btu/W-h) On or after July 10, 2020 5 Walk-in freezer dedicated condensing refrigeration system for use outdoors with a net refrigeration capacity of < 1900 W (6,500 Btu/h) Annual walk-in energy factor ≥ 6.522 x 10-5 x q net + 0.800 W-h/W-h (6.522 x 10-5 x q net + 2.73 Btu/W-h) On or after July 10, 2020 6 Walk-in freezer dedicated condensing refrigeration systems for use outdoors with a net refrigeration capacity of ≥ 1900 W (6,500 Btu/h) Annual walk-in energy factor ≥ 0.923 W-h/W-h (3.15 Btu/W-h) On or after July 10, 2020 7 Walk-in cooler unit coolers with a fan motor that operates using direct current or has a nominal voltage of not more than 480 V AC Annual walk-in energy factor ≥ 2.638 W-h/W-h (9.00 Btu/W-h) On or after July 10, 2020 8 Walk-in freezer unit coolers with a fan motor that operates using direct current or has a nominal voltage of not more than 480 V AC and with a net refrigeration capacity of < 4540 W (15,500 Btu/h) Annual walk-in energy factor ≥ 1.575 x 10-5 x q net + 1.146 W-h/W-h (1.575 x 10-5 x q net + 3.91 Btu/W-h) On or after July 10, 2020 9 Walk-in freezer unit coolers with a fan motor that operates using direct current or has a nominal voltage of not more than 480 V AC and with a net refrigeration capacity of ≥ 4540 W (15,500 Btu/h) Annual walk-in energy factor ≥ 1.216 W-h/W-h (4.15 Btu/W-h) On or after July 10, 2020

s. 667 — Information

For the purpose of subsection 5(1) of the Act, the following information must be collected in accordance with 10 C.F.R. Appendix C and provided to the Minister in respect of a walk-in refrigeration system:

its annual walk-in energy factor;

information that indicates whether it is designed and marketed for use indoors, outdoors or both;

information that indicates if it is for use in a walk-in cooler or walk-in freezer;

information that indicates if it has a unit cooler or a dedicated condensing refrigeration system; and

if it is a walk-in freezer unit cooler or dedicated condensing refrigeration system, its net refrigeration capacity expressed in watts.

Dry-type Transformers

s. 703 — Definitions

The following definitions apply in this Division.

CSA C802.2 means the CSA standard CAN/CSA-C802.2-00 entitled Minimum Efficiency Values for Dry-Type Transformers. (CSA C802.2)

CSA C802.2-12 means the CSA standard CAN/CSA-C802.2-12 entitled Minimum efficiency values for dry-type transformers. (CSA C802.2-12)

dry-type transformer means a transformer whose core and windings are in a gaseous or dry compound insulating medium and that is either single-phase with a nominal power of 15 to 833 kVA or three-phase with a nominal power of 15 to 7 500 kVA, has a nominal frequency of 60 Hz and has a high voltage winding of 35 kV or less. It does not include any of the following:

an autotransformer;

a drive (isolation) transformer that has two or more output windings or a nominal low-voltage line current of more than 1 500 A;

a grounding transformer;

a rectifier transformer;

a sealed transformer;

a non-ventilated transformer;

a testing transformer;

a furnace transformer;

a welding transformer;

a special impedance transformer;

a transformer that has a nominal low-voltage line current of 4 000 A or more;

an on-load regulating transformer;

a resistance grounding transformer; or

a transformer that is in a voltage class greater than 1.2 kV and that has a BIL of less than 20 kV or more than 199 kV. (transformateur à sec)

10 C.F.R. Appendix A means Appendix A to Subpart K, Part 431 of Title 10 to the United States Code of Federal Regulations, entitled Uniform Test Method for Measuring the Energy Consumption of Distribution Transformers, as amended from time to time. (appendice A 10 C.F.R.)

transformer means a static-electric device that consists of two or more coils of insulated wire, together with the necessary accessories, and that transfers alternating current by electromagnetic induction from one coil to another to change the original voltage. (transformateur)

s. 704 — Energy-using product

A dry-type transformer is prescribed as an energy-using product.

s. 704(2) — Limits

However, a dry-type transformer is not considered to be an energy-using product

for the purposes of sections 4 and 5, if it was manufactured before January 1, 2005; and

for the purpose of section 705, if it has a BIL of more than 150 kV and was manufactured before January 1, 2010.

s. 705 — Energy efficiency standards — manufactured before January 1, 2016

In respect of dry-type transformers that were manufactured on or after January 1, 2005 and before January 1, 2016, the energy efficiency standards set out in column 2 of the table to this section apply to dry-type transformers that were manufactured during the periods set out in column 3.

s. 705(2) — Testing standard

A dry-type transformer complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by the standard referred to in column 1 that are applicable to a dry-type transformer as defined in section 703. TABLE Column 1 Column 2 Column 3 Item Testing Standard Energy Efficiency Standard Period of Manufacture 1 CSA C802.2 CSA C802.2, Table 1 On or after January 1, 2005 and before January 1, 2010 2 CSA C802.2-12 CSA C802.2-12, Table 1 On or after January 1, 2010 and before January 1, 2016

s. 705.1 — Energy efficiency standard — single-phase and 1.2 kV voltage class

In respect of dry-type transformers that are single-phase, in the 1.2 kV voltage class and manufactured on or after January 1, 2016, the energy efficiency standards set out in column 2 of Table 1 to this section apply to dry-type transformers that have a kVA rating described in column 1.

s. 705.1(2) — Energy efficiency standards — single-phase and voltage class greater than 1.2 kV

In respect of dry-type transformers that are single-phase, in a voltage class greater than 1.2 kV and manufactured on or after January 1, 2016, the energy efficiency standards that are set out in relation to the product’s BIL rating set out in column 2 of Table 2 to this section apply to dry-type transformers that have a kVA rating set out in column 1.

s. 705.1(3) — Interpolation

For the purposes of subsections (1) and (2), if the kVA rating of the product falls between the kVA ratings set out in two consecutive items in column 1 of the applicable table to this section, the energy efficiency standard for the product is an interpolation of the corresponding energy efficiency standards set out in column 2.

s. 705.1(4) — Testing standard

A dry-type transformer complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by 10 C.F.R. Appendix A that are applicable to a dry-type transformer as defined in section 703. TABLE 1 Column 1 Column 2 Item kVA Rating% Efficiency When Tested at 35% of Nominal Load 1 15.0 97.70 2 25.0 98.00 3 37.5 98.20 4 50.0 98.30 5 75.0 98.50 6 100.0 98.60 7 167.0 98.70 8 250.0 98.80 9 333.0 98.90 TABLE 2 Column 1 Column 2 Item kVA Rating% Efficiency When Tested at 50% of Nominal Load 20-45 kV BIL> 45-95 kV BIL> 95-199 kV BIL 1 15.0 98.10 97.86 97.60 2 25.0 98.33 98.12 97.90 3 37.5 98.49 98.30 98.10 4 50.0 98.60 98.42 98.20 5 75.0 98.73 98.57 98.53 6 100.0 98.82 98.67 98.63 7 167.0 98.96 98.83 98.80 8 250.0 99.07 98.95 98.91 9 333.0 99.14 99.03 98.99 10 500.0 99.22 99.12 99.09 11 667.0 99.27 99.18 99.15 12 833.0 99.31 99.23 99.20

s. 705.2 — Energy efficiency standards — three-phase and 1.2 kV voltage class

In respect of dry-type transformers that are three-phase, in the 1.2 kV voltage class and manufactured on or after January 1, 2016, the energy efficiency standards set out column 2 of Table 1 to this section apply to dry-type transformers that have a kVA rating set out in column 1.

s. 705.2(2) — Energy efficiency standards — three-phase and voltage class greater than 1.2 kV

In respect of dry-type transformers that are three-phase, in a voltage class greater than 1.2 kV and manufactured on or after January 1, 2016, the energy efficiency standards that are set out in relation to the product’s BIL rating set out in column 2 of Table 2 to this section apply to dry-type transformers that have a kVA rating set out in column 1.

s. 705.2(3) — Interpolation

For the purposes of subsections (1) and (2), if the kVA rating of the product falls between the kVA ratings set out in two consecutive items in column 1 of the applicable table to this section, the energy efficiency standard for the product is an interpolation of the corresponding energy efficiency standards set out in column 2.

s. 705.2(4) — Reduced energy efficiency standard

The energy efficiency standard that is applicable to a dry-type transformer under this section is reduced by 0.11 if the transformer has multiple high-voltage windings and a voltage ratio other than 2:1.

s. 705.2(5) — Testing standard

A dry-type transformer complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by 10 C.F.R. Appendix A that are applicable to a dry-type transformer as defined in section 703. TABLE 1 Column 1 Column 2 Item kVA Rating% Efficiency When Tested at 35% of Nominal Load 1 15.0 97.89 2 30.0 98.23 3 45.0 98.40 4 75.0 98.60 5 112.5 98.74 6 150.0 98.83 7 225.0 98.94 8 300.0 99.02 9 500.0 99.14 10 750.0 99.23 11 1 000.0 99.28 TABLE 2 Column 1 Column 2 Item kVA Rating% Efficiency When Tested at 50% of Nominal Load 20-45 kV BIL> 45-95 kV BIL> 95-199 kV BIL 1 15.0 97.50 97.18 96.80 2 30.0 97.90 97.63 97.30 3 45.0 98.10 97.86 97.60 4 75.0 98.33 98.13 97.90 5 112.5 98.52 98.36 98.10 6 150.0 98.65 98.51 98.20 7 225.0 98.82 98.69 98.57 8 300.0 98.93 98.81 98.69 9 500.0 99.09 98.99 98.89 10 750.0 99.21 99.12 99.02 11 1 000.0 99.28 99.20 99.11 12 1 500.0 99.37 99.30 99.21 13 2 000.0 99.43 99.36 99.28 14 2 500.0 99.47 99.41 99.33 15 3 000.0 99.47 99.41 99.33 16 3 750.0 99.47 99.41 99.33 17 5 000.0 99.47 99.41 99.33 18 7 500.0 99.48 99.41 99.39

s. 706 — Information

For the purpose of subsection 5(1) of the Act, the following information must be provided to the Minister in respect of a dry-type transformer:

if applicable, information that indicates whether the transformer is in the 1.2 kV voltage class;

its BIL rating;

if applicable, information that indicates whether the transformer is a three-phase transformer that has multiple high-voltage windings and a voltage ratio other than 2:1;

its kVA rating;

its phase — namely, single-phase or three-phase;

the tested efficiency, expressed as a percentage;

the loss, expressed in watts, when it is under load and when it is not under load; and

if it is manufactured on or after January 1, 2010, the impedance, expressed as a percentage.

s. 706(2) — Standard

The information must be collected in accordance with one of the following standards:

CSA C802.2-12, if the product was manufactured on or after January 1, 2005 and before January 1, 2016; or

10 C.F.R. Appendix A, if the product is manufactured on or after January 1, 2016.

Motors

Definitions

s. 748 — Definitions

The following definitions apply in this Division.

CSA C390-10 means the CSA standard CSA C390-10 entitled Test methods, marking requirements, and energy efficiency levels for three-phase induction motors. (CSA C390-10)

IEC 60034-2-1 means the IEC standard CEI/IEC 60034-2-1 entitled Rotating electrical machines – Part 2-1: Standard methods for determining losses and efficiency from tests (excluding machines for traction vehicles). (CEI 60034-2-1)

IEEE 112 means the IEEE standard IEEE 112 entitled Standard Test Procedure for Polyphase Induction Motors and Generators. (IEEE 112)

Electric Motors

s. 749 — Definitions

The following definitions apply in this Subdivision.

CSA C390-10[Repealed, SOR/2022-265, s. 42]

electric motor means a machine that converts electrical power into rotational mechanical power and that

is an electric three-phase induction design;

is one of the following designs:

a NEMA design A, B or C with a three- or four-digit NEMA frame number,

an enclosed NEMA design A, B or C with a NEMA frame number of 56, or

an IEC design N or H with an IEC frame number of 80 or above;

has a nominal output power of not less than 0.75 kW (1 horsepower) and not more than 375 kW (500 horsepower);

has a cage or squirrel-cage design;

is rated for continuous duty or S1 operation;

is designed to operate at a single speed;

has a nominal voltage of not more than 600 V AC;

has a nominal frequency of 50 Hz, 50/60 Hz or 60 Hz;

has a two-, four-, six- or eight-pole construction;

has an open or enclosed construction; and

has an IP code from 00 to 67.

It does not include any of the following:

a motor that is cooled by air that is forced over the motor by a fan or blower that is not an integral part of the motor;

a liquid-cooled motor;

an inverter-only motor; or

a motor that is designed to operate continuously only while immersed. (moteur électrique)

explosion-proof motor means an electric motor

in respect of which measures have been taken to prevent excessive temperatures and the production of arcs or sparks by the motor; or

that is encased in an enclosure that can withstand the explosion of any flammable gas or vapour that might enter it, without being damaged and without transmitting the explosion to the outside. (moteur antidéflagrant)

footless means, in respect of an electric motor, that it does not have feet or detachable feet or that it is not designed to receive detachable feet. (sans pieds)

IEC 60034-5 means the IEC standard CEI/IEC 60034-5: 2006 entitled Rotating electrical machines - Part 5: Degrees of protection provided by the integral design of rotating electric machines (IP code) - Classification. (CEI 60034-5)

IEC 60529 means the IEC standard CEI/IEC 60529: 2013 entitled Degrees of Protection Provided by Enclosures (IP Code). (CEI 60529)

IEEE 112-2004[Repealed, SOR/2022-265, s. 42]

integral gear assembly means a product that consists of an electric motor and a gear mechanism that are combined in such a manner that

the end bracket or mounting flange forms an integral part of both the motor and the gear mechanism; and

if the motor and the gear mechanism are separated, only one of them remains intact. (assemblage d’engrenages intégrés)

IP code means the classification of the degree of protection provided by an enclosure, as set out in IEC 60034-5, IEC 60529 or NEMA MG-1. (code IP)

NEMA MG-1 means the NEMA standard MG 1 entitled NEMA MG 1 Motors and Generators. (NEMA MG-1)

s. 750 — Energy-using product

An electric motor is prescribed as an energy-using product.

s. 750(2) — Limits

However, for the purposes of sections 4, 5, 751 and 752, an electric motor is not considered to be an energy-using product if

it was manufactured before February 3, 1995;

it was manufactured before November 27, 1999 and is an explosion-proof motor or is part of an integral gear assembly;

it was manufactured before January 1, 2011 and it

has an eight-pole construction,

has NEMA U frame dimensions,

is a NEMA design C or an IEC design H,

is a close-coupled pump motor,

is a vertically mounted solid shaft normal thrust motor,

is a fire-pump motor or other NEMA design B motor with a nominal output power of more than 150 kW (200 horsepower) or is an IEC design N motor with a nominal output power of more than 150 kW (200 horsepower), or

is footless;

it was manufactured before June 1, 2016 and it

is a NEMA design A with a nominal output power of more than 150 kW (200 horsepower),

is an enclosed NEMA design with a NEMA frame number of 56,

has NEMA frame dimensions other than T or U,

has an IEC frame number of 80 or more but less than 90,

is a partial electric motor, a brake motor or a vertical hollow shaft motor,

is designed to operate continuously in free air, but can operate continuously for a period of at least 30 minutes while completely immersed,

has a separately powered blower,

has a base, end shields or flanges that are not within the dimensions specified in NEMA MG-1, or

has a NEMA shaft that is not a standard shaft, R-shaft or S-shaft, as specified in NEMA MG-1; or

it was manufactured before June 1, 2017 and is a medical-imaging motor.

s. 751 — Energy efficiency standards

The energy efficiency standards set out in column 3 of the table to this section apply to electric motors described in column 1 that are manufactured during the periods set out in column 4.

s. 751(2) — Testing standard

An electric motor complies with the energy efficiency standard if it meets the standard when tested at 100% of its nominal full load in accordance with testing procedures established by the standard set out in column 2 that are applicable to an electric motor as defined in section 749. TABLE Column 1 Column 2 Column 3 Column 4 Item Energy-using Product Testing Standard Energy Efficiency Standard Period of Manufacture 1 Electric motors that are fire-pump motors CSA C390-10, IEEE 112 or IEC 60034-2-1 CSA C390-10, Table 2 On or after February 3, 1995 2 Electric motors that are medical-imaging motors CSA C390-10, IEEE 112 or IEC 60034-2-1 NEMA MG-1, Table 12-12 On or after June 1, 2017 3 Electric motors that are part of an integral gear assembly; CSA C390-10 CSA C390-10, Table 2 On or after November 27, 1999 and before June 1, 2016 4 Electric motors that are close-coupled pump motors CSA C390-10 CSA C390-10, Table 2 On or after January 1, 2011 and before June 1, 2016 5 Electric motors that are vertically-mounted solid shaft normal thrust motors CSA C390-10 CSA C390-10, Table 2 On or after January 1, 2011 and before June 1, 2016 6 CSA C390-10 CSA C390-10, Table 2 On or after January 1, 2011 and before June 1, 2016 7 Electric motors other than motors described in items 1 to 6 CSA C390-10 CSA C390-10, Table 3 On or after February 3, 1995 and before June 1, 2016 8 Electric motors other than fire-pump motors or medical-imaging motors CSA C390-10, IEEE 112 or IEC 60034-2-1 NEMA MG-1, Table 12-12 On or after June 1, 2016

s. 752 — Information

For the purpose of subsection 5(1) of the Act, the following information must be provided to the Minister in respect of an electric motor: TABLE Column 1 Column 2 Column 3 Item Energy-using Product Testing Standard Information 1 Electric motors manufactured on or after February 3, 1995 and before June 1, 2016 CSA C390-10 2 Electric motors manufactured on or after June 1, 2016 CSA C390-10, IEEE 112 or IEC 60034-2-1

in respect of an electric motor for which a unique motor identifier was not provided under paragraph 5(1)(c),

its nominal output power, expressed in kilowatts (horsepower),

the number of poles, and

its construction — namely, open construction or enclosed construction; and

in respect of an electric motor described in column 1 of the table to this section, the information set out in column 3, which must be collected in accordance with the standard set out in column 2.

Small Electric Motors

s. 753 — Definitions

The following definitions apply in this Subdivision.

CSA C747-09 means the CSA standard CSA C747-09 entitled Energy efficiency test methods for small motors. (CSA C747-09)

IEEE 114-2010 means the IEEE standard IEEE 114-2010 entitled IEEE Standard Test Procedure for Single-Phase Induction Motors. (IEEE 114-2010)

small electric motor means a machine that converts electrical power into rotational mechanical power and that

has a nominal output power of not less than 0.18 kW (0.25 horsepower) and not more than 2.2 kW (3 horsepower);

is a NEMA design with a two-digit frame number or an IEC design with a frame number of 63 or 71;

has a nominal frequency of 50/60 Hz or 60 Hz;

has a two-, four- or six-pole construction;

operates using alternating current;

is one of the following types, namely, capacitor-start capacitor-run, capacitor-start induction-run or polyphase;

has an open construction;

is rated for continuous duty or S1 operation;

is designed to operate at a single speed; and

is designed as a general purpose motor.

It does not include a split-phase motor, shaded pole motor or permanent split-capacitor motor. (petit moteur électrique)

10 C.F.R. §431.446 means section 431.446 of Subpart X, Part 431 of Title 10 to the United States Code of Federal Regulations, as amended from time to time. (10 C.F.R. §431.446)

s. 754 — Energy-using product

A small electric motor is prescribed as an energy-using product.

s. 754(2) — Limits

However, for the purposes of sections 4, 5 and 755, a small electric motor is not considered to be an energy-using product if it was manufactured before March 9, 2015 or it is incorporated into any other product that is subject to these Regulations.

s. 755 — Energy efficiency standards

The energy efficiency standards set out in the applicable table in paragraph (a) of 10 C.F.R. §431.446 apply to a small motor.

s. 755(2) — Testing standard

A small electric motor complies with the energy efficiency standard if it meets that standard when

the product’s average full load efficiency is determined using horsepower and kilowatt ratings that are determined in accordance with paragraph (b) of 10 C.F.R. §431.446;

the product is tested at 100% of its nominal full load; and

the product is tested in accordance with testing procedures established by one of the following standards that are applicable to a small electric motor as defined in section 753:

if the motor is polyphase and has a nominal output power ≥ 0.18 kW (0.25 horsepower) but ≤ 0.75 kW (1 horsepower), CSA C747-09, IEEE 112 (Test Method A) or IEC 60034-2-1 (Test Method 2-1-1A),

if the motor is polyphase and has a nominal output power > 0.75 kW (1 horsepower) but ≤ 2.2 kW (3 horsepower), CSA C390-10, IEEE 112 (Test Method B) or IEC 60034-2-1 (Test Method 2-1-1B), or

if the motor is capacitor-start capacitor-run or capacitor-start induction-run, CSA C747-09, IEEE 114-2010 or IEC 60034-2-1 (Test Method 2-1-1A).

s. 756 — Information

For the purpose of subsection 5(1) of the Act, the following information must be provided to the Minister in respect of a small electric motor:

its average full load efficiency;

its type, namely, capacitor-start capacitor-run, capacitor-start induction-run or polyphase; and

if the motor is one for which a unique motor identifier has not been provided under paragraph 5(1)(c), its nominal output power expressed in kilowatts (horsepower) and the number of poles.

s. 756(2) — Standard

The information must be collected in accordance with one of the following standards:

if the motor is polyphase and has a nominal output power ≥ 0.18 kW (0.25 horsepower) but ≤ 0.75 kW (1 horsepower), CSA C747-09, IEEE 112 (Test Method A) or IEC 60034-2-1 (Test Method 2-1-1A);

if the motor is polyphase and has a nominal output power > 0.75 kW (1 horsepower) but ≤ 2.2 kW (3 horsepower), CSA C390-10, IEEE 112 (Test Method B) or IEC 60034-2-1 (Test Method 2-1-1B); or

if the motor is capacitor-start capacitor-run or capacitor-start induction-run, CSA C747-09, IEEE 114-2010 or IEC 60034-2-1 (Test Method 2-1-1A).

[Reserved, SOR/2018-201, s. 80]

[Reserved, SOR/2018-201, s. 80]

Plumbing Supply Fittings

s. 799 — Definition of 10 C.F.R. Appendix S

In this Division, 10 C.F.R. Appendix S means Appendix S to Subpart B, Part 430 of Title 10 to the United States Code of Federal Regulations, entitled Uniform Test Method for Measuring the Water Consumption of Faucets and Showerheads, as amended from time to time.

Commercial Pre-Rinse Spray Valves

s. 800 — Definitions

The following definitions apply in this Subdivision.

commercial pre-rinse spray valve means a handheld device for spraying water on food service items, that has a release-to-close valve and is designed and marketed to be used in conjunction with commercial dishwashing or commercial ware washing equipment. (pulvérisateur de prérinçage commercial)

10 C.F.R. §431.264 means the test method set out in section 431.264 of Subpart O, Part 431 of Title 10 to the United States Code of Federal Regulations, as amended from time to time. (10 C.F.R. §431.264)

10 C.F.R. §431.266 means the table to paragraph 431.266(b) of Subpart O, Part 431 of Title 10 to the United States Code of Federal Regulations, as amended from time to time. (10 C.F.R. §431.266)

s. 801 — Energy-using product

A commercial pre-rinse spray valve is prescribed as an energy-using product.

s. 801(2) — Limit

However, for the purposes of sections 4, 5 and 802, a commercial pre-rinse spray valve is not considered to be an energy-using product unless it is manufactured on or after June 27, 2016.

s. 802 — Energy efficiency standards

The energy efficiency standards set out in column 2 of the table to this section apply to commercial pre-rinse spray valves described in column 1 that are manufactured during the periods set out in column 3.

s. 802(2) — Testing standard

A commercial pre-rinse spray valve complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by 10 C.F.R. §431.264 that are applicable to a commercial pre-rinse spray valve as defined in section 800. TABLE Column 1 Column 2 Column 3 Item Energy-using Product Energy Efficiency Standard Period of Manufacture 1 Commercial pre-rinse spray valves Maximum water flow rate ≤ 6.1 L/min (1.6 gallons/min) On or after June 27, 2016 and before January 28, 2019 2 Commercial pre-rinse spray valves that have a spray force ≤ 1.39 N (5.0 ounce-force) Maximum water flow rate ≤ flow rate for “Product Class 1” commercial pre-rinse spray valve set out in 10 C.F.R. §431.266 On or after January 28, 2019 3 Commercial pre-rinse spray valves that have a spray force > 1.39 N (5.0 ounce-force) but ≤ 2.22 N (8.0 ounce-force) Maximum water flow rate ≤ flow rate for “Product Class 2” commercial pre-rinse spray valve set out in 10 C.F.R. §431.266 On or after January 28, 2019 4 Commercial pre-rinse spray valves that have a spray force > 2.22 N (8.0 ounce-force) Maximum water flow rate ≤ flow rate for “Product Class 3” commercial pre-rinse spray valve set out in 10 C.F.R. §431.266 On or after January 28, 2019

s. 803 — Information

For the purpose of subsection 5(1) of the Act, the following information must be collected in accordance with 10 C.F.R. §431.264 and provided to the Minister in respect of a commercial pre-rinse spray valve:

the maximum water flow rate, in litres per minute (gallons per minute); and

if it is manufactured on or after January 28, 2019, the spray force in newtons (ounce-force).

Faucets

s. 803.1 — Definitions

The following definitions apply in this Subdivision.

faucet means

a private lavatory faucet;

a replacement aerator for a private lavatory faucet;

a public lavatory faucet;

a replacement aerator for a public lavatory faucet;

a kitchen faucet, other than one that is designed and marketed exclusively for use in industrial, commercial or institutional kitchens;

a replacement aerator for a kitchen faucet, other than one that is designed and marketed exclusively for use in industrial, commercial or institutional kitchens; or

a metering faucet.

It does not include a faucet that is designed and marketed exclusively for use in health care facilities, a low-pressure water dispenser or a pot filler. (robinet)

low-pressure water dispenser means a terminal fitting that dispenses drinking water at a pressure of 105 kPa (15 psi) or less. (distributeur d’eau à basse pression)

pot filler means a terminal fitting that can accommodate only a single supply water inlet, with an articulated arm or the equivalent that allows the product to reach to fill vessels when in use and allows the product to be retracted when not in use. (robinet remplisseur)

s. 803.2 — Energy-using product

A faucet is prescribed as an energy-using product.

s. 803.2(2) — Limit

However, for the purposes of sections 4, 5 and 803.3, a faucet is not considered to be an energy-using product unless it is manufactured on or after July 1, 2026.

s. 803.3 — Energy efficiency standards

The energy efficiency standards set out in column 2 of the table to this section apply to faucets described in column 1.

s. 803.3(2) — Testing standard

A faucet complies with the energy efficiency standard if it meets that standard when tested in accordance with the applicable testing procedures established by 10 C.F.R. Appendix S. TABLE Column 1 Column 2 Item Energy-using Product Energy Efficiency Standard 1 Private lavatory faucets and replacement aerators for private lavatory faucets Maximum water flow rate ≤ 4.7 L/min (1.2 US gallons/min) measured at 414 kPa (60 psi) 2 Public lavatory faucets — other than metering faucets — and replacement aerators for public lavatory faucets Maximum water flow rate ≤ 2.0 L/min (0.5 US gallons/min) measured at 414 kPa (60 psi) 3 Kitchen faucets and replacement aerators for kitchen faucets Maximum water flow rate ≤ 7.0 L/min (1.8 US gallons/min), with optional temporary flow rate ≤ 8.5 L/min (2.2 US gallons/min) measured at 414 kPa (60 psi) 4 Metering faucets Maximum water flow rate ≤ 0.95 L/cycle (0.25 US gallons/cycle) measured at 414 kPa (60 psi)

s. 803.4 — Information

For the purpose of subsection 5(1) of the Act, the following information must be collected in accordance with 10 C.F.R. Appendix S and provided to the Minister in respect of a faucet:

its type;

the maximum water flow rate, expressed in litres per cycle (US gallons per cycle) for metering faucets and in litres per minute (US gallons per minute) for other faucets;

if the product is a kitchen faucet with the capacity for temporary flow rate increase, the maximum flow rate of that temporary flow, expressed in litres per minute (US gallons per minute), in addition to the information referred to in paragraph (b); and

the water pressure at which the maximum water flow rate was measured, expressed in kPa (psi).

Showerheads

s. 803.5 — Definition of showerhead

In this Subdivision, showerhead means a component or set of components with one or multiple nozzles that is intended for attachment to a single supply fitting for spraying water onto a bather. It does not include a showerhead designed and marketed exclusively for the emergency washing of a person who has been exposed to hazardous materials or a showerhead designed and marketed exclusively for use in health care facilities.

s. 803.6 — Energy-using product

A showerhead is prescribed as an energy-using product.

s. 803.6(2) — Limit

However, for the purposes of sections 4, 5 and 803.7, a showerhead is not considered to be an energy-using product unless it is manufactured on or after July 1, 2026.

s. 803.7 — Energy efficiency standard

The energy efficiency standards set out in column 2 of the table to this section apply to showerheads described in column 1. For showerheads with multiple nozzles, the maximum water flow rate applies regardless of the number of nozzles in use.

s. 803.7(2) — Testing standard

A showerhead complies with the energy efficiency standard if it meets that standard when tested in accordance with the applicable testing procedures established by 10 C.F.R. Appendix S. TABLE Item Column 1 Column 2 Energy-using Product Energy Efficiency Standard 1 Showerheads with one nozzle Maximum water flow rate ≤ 7.0 L/min (1.8 U.S. gallons/min) measured at 552 kPa (80 psi) 2 Showerheads with multiple nozzles Maximum water flow rate ≤ 7.0 L/min (1.8 U.S. gallons/min) measured at 552 kPa (80 psi)

s. 803.8 — Information

For the purpose of subsection 5(1) of the Act, the following information must be collected in accordance with 10 C.F.R. Appendix S and provided to the Minister in respect of a showerhead:

the number of nozzles;

the maximum water flow rate when all nozzles are used, expressed in litres per minute (US gallons per minute); and

the water pressure at which the maximum water flow rate was measured, expressed in kPa (psi).

Pumps

Clean Water Pumps

s. 804 — Definitions

The following definitions apply in this subdivision.

10 C.F.R. Appendix A means Appendix A to Subpart Y, Part 431 of Title 10 to the United States Code of Federal Regulations, entitled Uniform Test Method for the Measurement of Energy Consumption of Pumps, as amended from time to time. (appendice A 10 C.F.R.)

10 C.F.R. §431.465(b)(4) means the table to paragraph 431.465(b)(4) of Subpart Y, Part 431 of Title 10 to the United States Code of Federal Regulations, as amended from time to time. (10 C.F.R. §431.465(b)(4))

best efficiency point means the pump hydraulic power operating point that results in a maximum efficiency. (point de rendement maximal)

clean water means water that has a maximum non-absorbent solid content of 0.25 kg/m 3(0.016 lb/ft 3), a maximum dissolved solid content of 50 kg/m 3 (3.1 lb/ft 3) and a total gas content that does not exceed the saturation volume and that may include additives necessary to prevent the water from freezing down to -10°C (14°F). (eau claire)

clean water pump means a pump – with or without mechanical equipment, driver and controls, that is designed for pumping clean water – other than a fire pump, a self-priming pump, a prime-assist pump, a magnet-driven pump, a pump designed to be used in a nuclear facility, a pump designed to Canadian or United States military specifications or a pump designed and marketed for use as a pool pump, that

is one of the following types:

an end suction close-coupled pump with a maximum specific speed of 5000 RPM,

an end suction frame mounted pump with its own bearings and with a specific speed not more than 5000 RPM,

an in-line pump,

a radially split, multi-stage, vertical, in-line diffuser casing pump, or

a submersible turbine pump with a bowl diameter not greater than 152 mm (6 in),

has a shaft input power not less than 0.75 kW (1 horsepower) and not greater than 150 kW (200 horsepower) at best efficiency point and full impeller diameter;

has a flow rate of 5.68 m 3/h (25 US gallons/min) or greater at best efficiency point and full impeller diameter;

has a maximum head of 139.9 m (459 ft) at best efficiency point and full impeller diameter;

has a design temperature range that lies within -10 and 120°C (14 and 248°F); and

is designed to operate with either a 2-pole or 4-pole induction motor or a non-induction motor with a nominal speed of rotation of either 1800 RPM or 3600 RPM, as determined in accordance with 10 C.F.R. Appendix A, and in which the driver and impeller rotate at the same speed. (pompe à eau claire)

s. 805 — Energy-using product

A clean water pump is prescribed as an energy-using product.

s. 805(2) — Limit

However, for the purposes of sections 4, 5 and 806, a clean water pump is not considered to be an energy-using product unless it is manufactured on or after January 27, 2020.

s. 806 — Energy efficiency standard

The energy efficiency standard that applies to a clean water pump is the maximum pump energy index set out for the applicable equipment class in 10 C.F.R. §431.465(b)(4).

s. 806(2) — Testing standard

A clean water pump complies with the energy efficiency standard if it meets that standard when tested in accordance with testing procedures established by 10 C.F.R. Appendix A that apply to a clean water pump as defined in section 804.

s. 807 — Information

For the purpose of subsection 5(1) of the Act, the following information must be provided to the Minister in respect of a clean water pump:

its nominal power in kilowatts;

the impeller diameter in millimetres;

its type, namely, end suction close-coupled pump, end suction frame mounted with own bearings pump, in-line pump, radially split multi-stage, vertical, in-line diffuser casing pump or submersible turbine pump;

its nominal speed of rotation collected in accordance with 10 C.F.R. Appendix A;

its mode of operation, namely, constant load or variable load; and

its pump energy index value collected in accordance with 10 C.F.R. Appendix A.

Pool Pumps

s. 808 — Definitions

The following definitions apply in this Subdivision.

10 C.F.R. §431.465(f) means the table to paragraph (f) of section 431.465 of Subpart Y, Part 431 of Title 10 to the United States Code of Federal Regulations, as amended from time to time. (10 C.F.R. §431.465(f))

10 C.F.R. §431.465(g) means paragraph (g) of section 431.465 of Subpart Y, Part 431 of Title 10 to the United States Code of Federal Regulations, as amended from time to time. (10 C.F.R. §431.465(g))

10 C.F.R. §431.465(h) means paragraph (h) of section 431.465 of Subpart Y, Part 431 of Title 10 to the United States Code of Federal Regulations, as amended from time to time. (10 C.F.R. §431.465(h))

10 C.F.R. Appendix C means Appendix C to Subpart Y, Part 431 of Title 10 to the United States Code of Federal Regulations, entitled Uniform Test Method for the Measurement of Energy Efficiency of Dedicated-Purpose Pool Pumps, as amended from time to time. (appendice C 10 C.F.R.)

pool pump means, subject to subsection (2), a pump that is designed for use with a pool or spa and that is

a filter pump that has a hydraulic power of less than 1.865 kW (2.5 HP);

a pressure cleaner booster pump;

a waterfall pump with a maximum head less than or equal to 9.144 m (30 ft) and a maximum speed less than or equal to 1800 RPM;

a pump with an integral sand filter;

a pump with an integral cartridge filter;

a pump for a storable electric spa; or

a pump for a rigid electric spa. (pompe de piscine)

s. 808(2) — Exclusion — definition of pool pump

The definition pool pump in subsection (1) does not include

a clean water pump;

a circulator pump;

a submersible pump;

a pool filter pump with hydraulic output power equal to or greater than 1.865 kW (2.5 HP); or

a pump marketed exclusively for commercial use that has

an orifice on the pump body that accepts suction side plumbing connections that has an inner diameter greater than 72 mm (2.85 inches), and

a measured performance greater than or equal to 757 litres per minute (200 US gallons per minute) at 15.24 m (50 feet) of head.

s. 809 — Energy-using product

A pool pump is prescribed as an energy-using product.

s. 809(2) — Limit

However, for the purposes of sections 4, 5 and 810, a pool pump is not considered to be an energy-using product unless it is manufactured on or after January 1, 2026.

s. 810 — Energy efficiency standards

The energy efficiency standards set out in column 3 of the table to this section apply to pool pumps described in column 1.

s. 810(2) — Testing standard

A pool pump complies with the energy efficiency standard if it meets that standard when tested in accordance with the applicable testing procedures established by the standard, if any, set out in column 2 of the table to this section. TABLE Item Column 1 Column 2 Column 3 Energy-using Product Testing Standard Energy Efficiency Standard 1 Self-priming pool filter pumps that have a single phase electric motor and hydraulic horsepower of 0.711 HP or more but less than 2.5 HP 10 C.F.R. Appendix C 2 Self-priming pool filter pumps that have a single phase electric motor and hydraulic horsepower of less than 0.711 HP 10 C.F.R. Appendix C 3 Non-self-priming pool filter pumps that have hydraulic horsepower of less than 2.5 HP 10 C.F.R. Appendix C 4 Pressure cleaner booster pumps 10 C.F.R. Appendix C 5 Waterfall pumps 10 C.F.R. Appendix C 10 C.F.R. §431.465(h) 6 Integral sand filter pool pumps None 7 Integral cartridge filter pool pumps None 8 Storable electric spa pumps None 10 C.F.R. §431.465(h) 9 Rigid electric spa pumps None 10 C.F.R. §431.465(h)

s. 811 — Information

For the purpose of subsection 5(1) of the Act, the following information must be provided to the Minister in respect of a pool pump:

its type;

its nominal motor power, expressed in watts;

its nominal hydraulic power, expressed in watts;

its total power, expressed in watts;

in the case of a self-priming pool filter pump, a non-self-priming pool filter pump, a waterfall pump or a pressure cleaner booster pump, its weighted energy factor;

in the case of a pool pump with an integral filter, information that indicates whether it has a separate or built-in timer;

information that indicates whether it has freeze protection controls;

in the case of a pool pump with freeze protection controls, information that indicates whether freeze protection is enabled or disabled; and

in the case of a pool pump with freeze protection controls that are enabled, its default dry-bulb air temperature setting, default run-time and default motor speed.

Air Compressors

s. 812 — Definitions

The following definitions apply in this Division.

10 C.F.R. §431.345 means the table to section 431.345 to Subpart T, Part 431 of Title 10 to the United States Code of Federal Regulations, as amended from time to time. (10 C.F.R. §431.345)

10 C.F.R. Appendix A means Appendix A to Subpart T, Part 431 of Title 10 to the United States Code of Federal Regulations, entitled Uniform Test Method for Certain Air Compressors, as amended from time to time. (appendice A 10 C.F.R.)

air compressor means a lubricated rotary compressor that is designed to compress air, has an inlet open to the atmosphere or another source of air, is made up of one or more compression elements (bare compressors), one or more drivers, mechanical equipment to drive the compression elements and any ancillary equipment and has all of the following features:

it is driven by a brushless three-phase electric motor;

it is air- or liquid-cooled;

it is fixed- or variable-speed;

it has a full-load operating pressure that is greater than or equal to 0.52 MPa (75 psig) and less than or equal to 1.38 MPa (200 psig);

it has a full-load actual volume flow rate that is greater than or equal to 0.99 m 3/min (35 cfm) or has a motor whose nominal power is greater than or equal to 7.46 kW (10 HP); and

it has a full-load actual volume flow rate that is less than or equal to 35.4 m 3/min (1250 cfm) or is sold or supplied with a compressor motor whose nominal power is less than or equal to 149.14 kW (200 HP).

It does not include a liquid ring compressor, a reciprocating compressor or a rotary-type positive displacement compressor for use in the petroleum, petrochemical or natural gas industries. (compresseur d’air)

compressor means a machine or apparatus that converts different types of energy into the potential energy of gas pressure for displacement and compression of gaseous media to any pressure value above atmospheric pressure and has a pressure ratio at full-load operating pressure greater than 1.3. (compresseur)

s. 813 — Energy-using product

An air compressor is prescribed as an energy-using product.

s. 813(2) — Limit

However, for the purposes of sections 4, 5 and 814, an air compressor is not considered to be an energy-using product unless it is manufactured on or after July 1, 2026.

s. 814 — Energy efficiency standard

The energy efficiency standard that applies to an air compressor is the minimum package isentropic efficiency set out for the applicable equipment class in 10 C.F.R. §431.345.

s. 814(2) — Testing standard

An air compressor complies with the energy efficiency standard if it meets that standard when tested in accordance with the applicable testing procedures established by 10 C.F.R. Appendix A.

s. 815 — Information

For the purpose of subsection 5(1) of the Act, the following information must be collected in accordance with 10 C.F.R. Appendix A and provided to the Minister in respect of an air compressor:

its equipment class;

the air compressor motor nominal power, expressed in kilowatts (HP);

its dimensionless full-load package isentropic efficiency or part-load package isentropic efficiency, as applicable;

its full-load actual volume flow rate, expressed in m 3/min (cfm);

its full-load operating pressure, expressed in MPa (psig);

its maximum full-flow operating pressure, expressed in MPa (psig);

its pressure ratio at full-load operating pressure; and

if any ancillary equipment that is not part of the air compressor package is installed for testing,

a description of the ancillary equipment,

the manufacturer of the ancillary equipment and, if it is different than the manufacturer, the brand,

the model number of the ancillary equipment,

the serial number of the ancillary equipment, if any, and

the input voltage, number of phases and input frequency of the ancillary equipment, if applicable.

The graphic depicts the form for the bilingual EnerGuide label for a household appliance and provides instructions for the information that must be on the label. Except for the EnerGuide logo, which has white text on a black background, all text on the label is black on a white background. The label displays the following information about the appliance: its annual energy consumption, its type and size category and its model number. The label also displays a horizontal scale that shows the annual energy consumption of the product, expressed in kilowatts, relative to similar models in the same size and type category. From top to bottom, the elements of the label and their associated instructions are the following: The Canada word-mark is at the top of the graphic. The EnerGuide logo is prominently displayed underneath the Canada word-mark. Below, under the heading “Energy consumption”, the value “AAA kWh per year” is prominently displayed. The instruction for this value states “Replace “AAA” with annual energy consumption of model in kilowatt hours”. Next, the label depicts a gradient scale that gradually changes from white on the left to black on the right. The value “BBB kWh” is displayed at the left endpoint of the scale, immediately above a bolded heading that states “Uses least energy”. The instruction for this value states “Replace “BBB” with value of most energy-efficient model within same type and size category.” The value “CCC kWh” is displayed at the right endpoint of the scale, immediately above a bolded heading that states “Uses most energy”. The instruction for this value states “Replace “CCC” with value of least energy-efficient model within same type and size category.” Immediately above the scale and depicted as an inverted black triangle is the energy consumption indicator which is used to mark the relative energy performance of the product at issue. The instruction for this indicator states “Position model on annual energy consumption scale relative to others within same type and size category.” Next below, at the left margin, is the heading “Similar models compared”. The values “DDD” and “EEE”, which are related to this heading, are centered on the graphic. The instruction for those values states “Replace “DDD” with applicable type, if any, and replace “EEE” with applicable size category, if any.” Next below, at the left margin, is the heading “Model number”. The value “FFF”, which is related to this heading, is centered on the graphic. The instruction for this value states “Replace “FFF” with model number.” Lastly, the graphic provides a reminder that “Removal of this label before first retail purchase is an offence (S.C. 1992, c. 36)”. The graphic depicts the form of the bilingual EnerGuide label for a household appliance and provides the external dimensions of the label and the font types and sizes. The exterior dimensions of the label are 13.49 cm by 14.76 cm. The colour of the label is black and white. The font and size requirements of the elements of the graphic, from top to bottom, are as follows: The EnerGuide logo is in 42.8 pt. Helvetica Black, with -2.5 pt. letter spacing. The heading “Energy consumption” is in 13.5 pt. Helvetica bold. The “AAA” portion of the value “AAA kWh” is in 82 pt. Helvetica bold, with -2 pt. letter spacing. The “kWh” portion of the value “AAA kWh” is in 32 pt. Helvetica bold, with -2 pt. letter spacing. The words “per year” are in 13.5 pt. Helvetica bold. The words “This model”, which appear next to the energy consumption indicator, are in 8 pt. Helvetica. The values “BBB kWh” and “CCC kWh” are in 10 pt. Helvetica. The headings “Uses least energy” and “Uses most energy” are in 11.5/12 pt. Helvetica. The headings “Similar models compared” and “Model number” are in 9.5 pt. Helvetica. The value “DDD” is in 10 pt. Helvetica bold. The value “EEE” is in 9 pt. Helvetica bold italic. The value “FFF” is in 11 pt. Helvetica bold. The offence reminder statement is in 7 pt. Helvetica.

Explanation for Elements on Household Appliance Energy Efficiency Label / Explication du contenu de l’étiquette indiquant l’efficacité énergétique des appareils domestiques

The graphic depicts the form of the bilingual EnerGuide label for a room air conditioner manufactured before June 2014 and provides instructions for the information that must be on the label. Except for the EnerGuide logo, which has white text on a black background, all text on the label is black on a white background. The label displays the following information about the room air conditioner: its energy efficiency ratio, its type and cooling capacity category and its model number. The label also displays a horizontal scale that shows the energy efficiency of the product relative to similar models in the same size and cooling capacity category. From top to bottom, the elements of the label and their associated instructions are the following: The Canada word-mark is at the top of the graphic. The EnerGuide logo is prominently displayed underneath the Canada word-mark. Below, under the heading “Energy Efficiency Ratio (EER)”, the value “A.A” is prominently displayed. The instruction for this value states “Replace “A.A” with energy efficiency ratio of room air conditioner.” Next, the label depicts a gradient scale that gradually changes from black on the left to white on the right. The value “B.B” is displayed at the left endpoint of the scale, immediately above a bolded heading that states “Least energy-efficient”. The instruction for this value states “Replace “B.B” with value of least energy-efficient model within same type and cooling capacity category.” The value “C.C” is displayed at the right endpoint of the scale, immediately above a bolded heading that states, “Most energy-efficient”. The instruction for this value states “Replace “C.C” with value of most energy-efficient model within same type and cooling capacity category.” Immediately above the scale and depicted as an inverted black triangle is the energy efficiency ratio indicator, which is used to mark the relative energy efficiency of the product at issue. The instruction for this indicator states “Position model on energy efficiency ratio scale relative to others within same type and cooling capacity category.” Next below, at the left margin, is the heading “Similar models compared”. The values “DDD” and “EEE”, which are related to this heading, are centered on the graphic. The instruction for those values states “Replace “DDD” with applicable type and replace “EEE” with applicable cooling capacity category, if any.” Next below, at the left margin, is the heading “Model number”. The value “FFF”, which is related to this heading, is centered on the graphic. The instruction for this value states “Replace “FFF” with model number.” Lastly, the graphic provides a reminder that “Removal of this label before first retail purchase is an offence (S.C. 1992, c. 36)”. The graphic depicts the form of the bilingual EnerGuide label for a room air conditioner manufactured before June 2014 and provides the external dimensions of the label and the font types and sizes. The exterior dimensions of the label are 13.49 cm by 14.76 cm. The colour of the label is black and white. The font and size requirements of the elements of the graphic, from top to bottom, are as follows: The EnerGuide logo is in 42.8 pt. Helvetica Black, with -2.5 pt. letter spacing. The heading “Energy Efficiency Ratio” is in 12.5 pt. Helvetica bold. The acronym “EER” is located immediately beside that heading, is boxed and is in 13.5 pt. Helvetica bold, with -2 pt. letter spacing. The value “A.A” is in 82 pt. Helvetica bold, with -2 pt. letter spacing. The words “This model”, which appear next to the energy consumption indicator, are in 8 pt. Helvetica. The values “B.B.” and “C.C.” are in 10 pt. Helvetica. The headings “Least energy-efficient” and “Most energy-efficient” are in 11.5/12 pt. Helvetica bold. The headings “Similar models compared” and “Model number” are in 9.5 pt. Helvetica. The value “DDD” is in 10 pt. Helvetica bold. The value “EEE” is in 9 pt. Helvetica bold italic. The value “FFF” is in 11 pt. Helvetica bold. The offence reminder statement is in 7 pt. Helvetica.

Explanation for Elements on Room Air Conditioner Energy Efficiency Label / Explication du contenu de l’étiquette indiquant l’efficacité énergétique des climatiseurs individuels

The graphic depicts the form of the bilingual EnerGuide label for a room air conditioner manufactured on or after June 1, 2014 and provides instructions for the information that must be on the label. Except for the EnerGuide logo, which has white text on a black background, all text on the label is black on a white background. The label displays the following information about the room air conditioner: its combined energy efficiency ratio, its type and cooling capacity category and its model number. The label also displays a horizontal scale that shows the combined energy efficiency ratio of the product relative to other products of the same type and in the same cooling capacity category. From top to bottom, the elements of the label and their associated instructions are the following: The Canada word-mark is at the top of the graphic. The EnerGuide logo is prominently displayed underneath the Canada word-mark. Below, under the heading “Combined Energy Efficiency Ratio”, the value “A.A” is prominently displayed. The instruction for this value states “Replace “A.A” with combined energy efficiency ratio of room air conditioner.” Next, the label depicts a gradient scale that gradually changes from black on the left to white on the right. The value “B.B” is displayed at the left endpoint of the scale, immediately above a bolded heading that states “Least energy efficient”. The instruction for this value states “Replace “B.B” with the value of least energy-efficient model within same type and cooling capacity category.” The value “C.C” is displayed at the right endpoint of the scale, immediately above a bolded heading that states “Most energy efficient”. The instruction for this value states “Replace “C.C” with value of most energy-efficient model within same type and cooling capacity category.” Immediately above the scale and depicted as an inverted black triangle is the combined energy efficiency ratio indicator that is used to mark the relative energy efficiency of the product at issue. The instruction for this indicator states “Position model on combined energy efficiency ratio scale relative to others within same type and cooling capacity category.” Next below, at the left margin, is the heading “Similar models compared”. The values “DDD” and “EEE”, which related to this heading, are centered on the graphic. The instruction for those values states “Replace “DDD” with applicable type and replace “EEE” with applicable cooling capacity category, if any.” Next below, at the left margin, is the heading “Model number”. The value “FFF”, which is related to this heading, is centered on the graphic. The instruction for this value states “Replace “FFF” with model number.” Lastly, the graphic provides a reminder that “Removal of this label before first retail purchase is an offence (S.C. 1992, c. 36)”. The graphic depicts the form of the bilingual EnerGuide label for a room air conditioner manufactured on or after June 1, 2014 and provides the external dimensions of the label and the font types and sizes. The exterior dimensions of the label are 13.49 cm by 14.76 cm. The colour of the label is black and white. The font and size requirements of the elements of the graphic, from top to bottom, are the following: The EnerGuide logo is in 42.8 pt. Helvetica black, with -2.5 pt. letter spacing. The heading “Combined Energy Efficiency Ratio” is in 9 pt. Helvetica bold. The acronym “CEER” is located immediately beside that heading, is boxed and is in 10 pt. Helvetica bold, with -2 pt. letter spacing. The value “A.A” is in 82 pt. Helvetica bold, with -2 pt. letter spacing. The words “This model”, which appear next to the combined energy ratio indicator, are in 8 pt. Helvetica. The values “B.B” and “C.C” are in 10 pt. Helvetica. The headings “Least energy-efficient” and “Most energy-efficient” are in 11.5/12 pt. Helvetica bold. The headings “Similar models compared” and “Model number” are in 9.5 pt. Helvetica. The value “DDD” is in 10 pt. Helvetica bold. The value “EEE” is in 9 pt. Helvetica bold italic. The value “FFF” is in 11 pt. Helvetica bold. The offence reminder statement is in 7 pt. Helvetica.

Explanation for Elements on Room Air Conditioner Energy Efficiency Label / Explication du contenu de l’étiquette indiquant l’efficacité énergétique des climatiseurs individuels

The graphic depicts the form of the bilingual EnerGuide label for a portable air conditioner manufactured on or after January 10, 2025 and provides instructions for the information that must be on the label. Except for the EnerGuide logo, which has white text on a black background, all text on the label is black on a white background. The label displays the following information about the portable air conditioner: its combined energy efficiency ratio, the product category and its model number. The label also displays a horizontal scale that shows the combined energy efficiency ratio of the product relative to other products of the same category. From top to bottom, the elements of the label and their associated instructions are the following: The Canada word-mark is at the top of the graphic. The EnerGuide logo is prominently displayed underneath the Canada word-mark. Below, under the heading “Combined Energy Efficiency Ratio”, the value “A.A” is prominently displayed. The instruction for this value states “Replace “A.A” with combined energy efficiency ratio of portable air conditioner.” Next, the label depicts a gradient scale that gradually changes from black on the left to white on the right. The value “B.B” is displayed at the left endpoint of the scale, immediately above a bolded heading that states “Least energy efficient”. The instruction for this value states “Replace “B.B” with the value of least energy-efficient model.” The value “C.C” is displayed at the right endpoint of the scale, immediately above a bolded heading that states “Most energy efficient”. The instruction for this value states “Replace “C.C” with value of most energy-efficient model.” Immediately above the scale and depicted as an inverted black triangle is the combined energy efficiency ratio indicator that is used to mark the relative energy efficiency of the product at issue. The instruction for this indicator states “Position model on combined energy efficiency ratio scale relative to others.” Next below, at the left margin, is the heading “Similar models compared”. The value “DDD”, which is related to this heading, is centered on the graphic. The instruction for this value states “Replace “DDD” with single-duct and dual-duct portable air conditioners.” Next below, at the left margin, is the heading “Model number”. The value “FFF”, which is related to this heading, is centered on the graphic. The instruction for this value states “Replace “FFF” with model number.” Lastly, the graphic provides a reminder that “Removal of this label before first retail purchase is an offence (S.C. 1992, c. 36)”. The graphic depicts the form of the bilingual EnerGuide label for a portable air conditioner manufactured on or after January 10, 2025 and provides the external dimensions of the label and the font types and sizes. The exterior dimensions of the label are 13.49 cm by 14.76 cm. The colour of the label is black and white. The font and size requirements of the elements of the graphic, from top to bottom, are the following: The EnerGuide logo is in 42.8 pt. Helvetica black, with -2.5 pt. letter spacing. The heading “Combined Energy Efficiency Ratio” is in 9 pt. Helvetica bold. The acronym “CEER” is located immediately beside that heading, is boxed and is in 10 pt. Helvetica bold, with -2 pt. letter spacing. The value “A.A” is in 82 pt. Helvetica bold, with -2 pt. letter spacing. The words “This model”, which appear next to the combined energy ratio indicator, are in 8 pt. Helvetica. The values “B.B” and “C.C” are in 10 pt. Helvetica. The headings “Least energy-efficient” and “Most energy-efficient” are in 11.5/12 pt. Helvetica bold. The headings “Similar models compared” and “Model number” are in 9.5 pt. Helvetica. The value “DDD” is in 10 pt. Helvetica bold. The value “FFF” is in 11 pt. Helvetica bold. The offence reminder statement is in 7 pt. Helvetica.

Explanation for Elements on Portable Air Conditioner Energy Efficiency Label / Explication du contenu de l’étiquette indiquant l’efficacité énergétique des climatiseurs portables