Delaware State Fire Prevention Commission
Delaware State Fire Prevention Commission
Delaware State Fire Prevention Regulations
Appendix A
This Appendix is not part of the requirements of this regulation, but is included for informational purposes only.
The material contained in Appendix A of the Delaware State Fire Prevention Regulations is interspersed among the verbiage of Parts 701 through Part 706 of this regulation and, therefore, Appendix A is not repeated here. Appendix A material is shown as a " Note" directly after the paragraph in which it addresses.
Appendix B
Delaware Statutes Governing State Fire Prevention Commission and State Fire Marshall
Title 16 Health and Safety:
Chapter 64: http://delcode.delaware.gov/title16/c064/index.shtml Amusement Rides Safety Inspection and Insurance Act
http://delcode.delaware.gov/title16/c066/sc01/index.shtml Subchapter I. State Fire Marshall and State Fire Prevention Commission
http://delcode.delaware.gov/title16/c066/sc02/index.shtml Subchapter II. Smoke Detectors
http://delcode.delaware.gov/title16/c066/sc03/index.shtml Subchapter III. False Fire Alarms
Chapter 88: http://delcode.delaware.gov/title16/c088/index.shtml Student Dormitories and Student Residential Housing Fire Suppression System
Appendix C
Cross Reference of Statutes Applicable to Fire Regulations
Delaware Code cross reference for those sections applicable to the Delaware State Fire Regulations.
Title 7 Conservation:
Chapter 7, Section 713: http://delcode.delaware.gov/title7/c007/sc01/index.shtml#713 Fire regulations; penalty.
Title 11 Crimes and Criminal Procedure:
Section 501 http://delcode.delaware.gov/title11/c005/sc01/index.shtml#501 Criminal solicitation in the third degree; class A misdemeanor
Section 502 http://delcode.delaware.gov/title11/c005/sc01/index.shtml#502 Criminal solicitation in the second degree; class F felony
Section 503 http://delcode.delaware.gov/title11/c005/sc01/index.shtml#503 Criminal solicitation in the first degree; class E felony
Section 511 http://delcode.delaware.gov/title11/c005/sc01/index.shtml#511 Conspiracy in the third degree; class A misdemeanor.
Section 512 http://delcode.delaware.gov/title11/c005/sc01/index.shtml#512 Conspiracy in the second degree; class G felony.
Section 513 http://delcode.delaware.gov/title11/c005/sc01/index.shtml#513 Conspiracy in the first degree; class E felony.
Section 531 http://delcode.delaware.gov/title11/c005/sc01/index.shtml#531 Attempt to commit a crime.
Subpart A. Assaults and Related Offenses
Section 603 http://delcode.delaware.gov/title11/c005/sc02/index.shtml#603 Reckless endangering in the second degree; class A misdemeanor
Section 604 http://delcode.delaware.gov/title11/c005/sc02/index.shtml#604 Reckless endangering in the first degree; class E felony.
Section 621 http://delcode.delaware.gov/title11/c005/sc02/index.shtml#621 Terroristic threatening.
Subpart A. Arson and Related Offenses
Section 801 http://delcode.delaware.gov/title11/c005/sc03/index.shtml#801 Arson in the third degree; affirmative defense; class G felony.
Section 802 http://delcode.delaware.gov/title11/c005/sc03/index.shtml#802 Arson in the second degree; affirmative defense; class D felony.
Section 803 http://delcode.delaware.gov/title11/c005/sc03/index.shtml#803 Arson in the first degree; class C felony.
Section 804 http://delcode.delaware.gov/title11/c005/sc03/index.shtml#804 Reckless burning or exploding; class A misdemeanor
Section 805 http://delcode.delaware.gov/title11/c005/sc03/index.shtml#805 Cross or religious symbol burning; class A misdemeanor
Section 843 http://delcode.delaware.gov/title11/c005/sc03/index.shtml#843 Theft; false pretense.
Section 846 http://delcode.delaware.gov/title11/c005/sc03/index.shtml#846 Extortion; class E felony.
Section 871 http://delcode.delaware.gov/title11/c005/sc03/index.shtml#871 Falsifying business records; class A misdemeanor.
Section 913 http://delcode.delaware.gov/title11/c005/sc03/index.shtml#913 Insurance fraud; class G felony.
Subpart A. Bribery and Improper Influence
Section 1243 http://delcode.delaware.gov/title11/c005/sc06/index.shtml#1243 Obstructing fire-fighting operations; class A misdemeanor
Section 1244 http://delcode.delaware.gov/title11/c005/sc06/index.shtml#1244 Hindering prosecution; class A misdemeanor
Section 1245 http://delcode.delaware.gov/title11/c005/sc06/index.shtml#1245 Falsely reporting an incident; class A misdemeanor.
Subpart A. Riot, Disorderly Conduct and Related Offenses
Section 1323 http://delcode.delaware.gov/title11/c005/sc07/index.shtml#1323 Obstructing public passages; violation
Section 1338 http://delcode.delaware.gov/title11/c005/sc07/index.shtml#1338 Bombs, incendiary devices, Molotov cocktails and explosive devices; class D felony.
Title 16 Health and Safety:
Chapter 64 Chapter 64 http://delcode.delaware.gov/title16/c064/index.shtml Amusement Rides Safety Inspection and Insurance Act:
http://delcode.delaware.gov/title16/c065/index.shtml Liability for negligent burning.
Subchapter I: http://delcode.delaware.gov/title16/c066/sc01/index.shtml State Fire Marshal and State Fire Prevention Commission
Subchapter II: http://delcode.delaware.gov/title16/c066/sc02/index.shtml Smoke Detectors
Subchapter III: http://delcode.delaware.gov/title16/c066/sc03/index.shtml False Fire Alarms
Section 6901 http://delcode.delaware.gov/title16/c069/index.shtml#6901 Selling or possessing fireworks; exceptions.
Section 6902 http://delcode.delaware.gov/title16/c069/index.shtml#6902 Discharging rifle or other explosives; exceptions.
Section 6903 http://delcode.delaware.gov/title16/c069/index.shtml#6903 Permit for public display of fireworks; actions by injured persons.
Section 6904 http://delcode.delaware.gov/title16/c069/index.shtml#6904 Confiscation of illegally stored fireworks or explosives.
Section 7001 http://delcode.delaware.gov/title16/c070/index.shtml#7001 Signs on premises containing stored explosives.
Section 7002 http://delcode.delaware.gov/title16/c070/index.shtml#7002 Exceptions.
Section 7003 http://delcode.delaware.gov/title16/c070/index.shtml#7003 Penalties
Chapter 71 Sale, Purchase, Receipt, Possession, Transportation, Use, Safety and Control of Explosive Materials
Section 7101 http://delcode.delaware.gov/title16/c071/index.shtml#7101 Scope
Section 7102 http://delcode.delaware.gov/title16/c071/index.shtml#7102 Definitions
Section 7103 http://delcode.delaware.gov/title16/c071/index.shtml#7103 General Provisions
Section 7104 http://delcode.delaware.gov/title16/c071/index.shtml#7104 Purchase, receipt and possession
Section 7105 http://delcode.delaware.gov/title16/c071/index.shtml#7105 Sale
Section 7106 http://delcode.delaware.gov/title16/c071/index.shtml#7106 Licensed blasters
Section 7107 http://delcode.delaware.gov/title16/c071/index.shtml#7107 Administration
Section 7108 http://delcode.delaware.gov/title16/c071/index.shtml#7108 Authority to purchase in contiguous states
Section 7109 http://delcode.delaware.gov/title16/c071/index.shtml#7109 Records
Section 7110 http://delcode.delaware.gov/title16/c071/index.shtml#7110 Safety
Section 7111 http://delcode.delaware.gov/title16/c071/index.shtml#7111 Notice to affected persons
Section 7112 http://delcode.delaware.gov/title16/c071/index.shtml#7112 Transportation
Chapter 73 http://delcode.delaware.gov/title16/c073/index.shtml Products Utilizing Petroleum Derivatives
Chapter 75 http://delcode.delaware.gov/title16/c075/index.shtml Fire Excapes and Exits
Chapter 88 http://delcode.delaware.gov/title16/c088/index.shtml Student Dormitories and Student Residential Housing Fire Suppression Systems
Title 21
Chapter 70 http://delcode.delaware.gov/title21/c070/index.shtml Fire Lanes
Title 29
Chapter 82 Sections 8223-8230 of this title shall be known and may be cited as the "Hazardous Materials Transportation Act of 1979."
Section 8222 http://delcode.delaware.gov/title29/c082/index.shtml#8222 Short Title
Section 8223 http://delcode.delaware.gov/title29/c082/index.shtml#8223 Declaration of policy; findings of fact
Section 8224 http://delcode.delaware.gov/title29/c082/index.shtml#8224 Definitions
Section 8225 http://delcode.delaware.gov/title29/c082/index.shtml#8225 Adoption of federal requirements
Section 8226 http://delcode.delaware.gov/title29/c082/index.shtml#8226 State Emergency Response Commission
Section 8227 http://delcode.delaware.gov/title29/c082/index.shtml#8227 Remedies
Section 8228 http://delcode.delaware.gov/title29/c082/index.shtml#8228 Jurisdiction; penalties
Section 8229 http://delcode.delaware.gov/title29/c082/index.shtml#8229 Exclusive state regulation; general repealer
Appendix D
NFPA Publications For Guidance
Numerical Listing
The following Standards, Recommendations, Recommended Practices, Manuals, Guides, and Model Laws are included here for reference and guidance in the application of the State of Delaware Fire Prevention Rules and Regulations when a particular problem is not otherwise covered by a Code, Standard, or Law Provision. The Fire Marshal may use the provisions of these Standards, Recommendations, Recommended Practices, Manuals, Guides, and Model Laws as appropriate criteria for meeting the intent of the State of Delaware Fire Prevention Rules and Regulations in those cases.
NFPA NO. | DATE OF PUBLI-CATION | TITLE 11C | 1995 | Mobile Foam Apparatus, Standard for 43D | 1994 | Code for the Storage of Pesticides 46 1 | 1996 | Recommended Safe Practice for Storage of Forest Products 49 | 1994 | Hazardous Chemicals Data 53 1 | 2004 | Guide on Fire Hazards in Oxygen Enriched Atmospheres 68 1 | 2002 | Guide for Venting of Deflagrations 70B 1 | 2006 | Recommended Practice for Electrical Equipment Maintenance 70E 1 | 2004 | Standard for Electrical Safety Requirements for Employee Workplaces 77 1 | 2000 | Recommended Practice on Static Electricity 80A 1 | 2001 | Recommended Practice for Protection of Buildings from Exterior Fire Exposures 85 1 | 2004 | Boiler and Combustion Systems Hazards Code 97 | 1996 | Standard Glossary of Terms Relating to Chimneys, Vents, and Heat-Producing Appliances 99B 1 | 2005 | Standard for Hypobaric Facilities 101A 1 | 2004 | Guide on Alternative Approaches to Life Safety 105 1 | 2003 | Standard for the Installation of Smoke Door Assemblies 115 1 | 2003 | Standard for Laser Fire Protection 130 1 | 2003 | Standard for Fixed Guideway Transit Systems 203 | 1995 | Guide for Roof Coverings and Roof Deck Construction 204 1 | 2002 | Standard for Smoke and Heat Venting 231E 1 | 1996 | Recommended Practice for the Storage of Baled Cotton 232 1 | 2000 | Standard for Protection of Records 251 1 | 2006 | Standard Methods of Tests of Fire Resistance of Building Construction and Materials 252 1 | 2003 | Standard Methods of Fire Tests of Door Assemblies 253 1 | 2006 | Standard Method of Test for Critical Radiant Flux of Floor Covering Systems Using a Radiant Heat Energy Source 255 1 | 2006 | Standard Method of Test of Surface Burning Characteristics of Building Materials 256 1 | 2003 | Standard Methods of Fire Tests of Roof Coverings 257 1 | 2000 | Standard on Fire Test for Window and Glass Block Assemblies 258 | 2001 | Standard Research Test Method for Determining Smoke Generation of Solid Materials 259 1 | 2003 | Standard Test Method for Potential Heat of Building Materials 260 1 | 2003 | Standard Methods of Tests and Classification System for Cigarette Ignition Resistance of Components of Upholstered Furniture 261 1 | 2003 | Standard Method of Test for Determining Resistance of Mock-Up Upholstered Furniture Material Assemblies to Ignition by Smoldering Cigarettes 262 1 | 2002 | Standard Method of Test for Flame Travel and Smoke of Wires and Cables for Use in Air-Handling Spaces 263 | 1994 | Heat and Visible Smoke Release Rates for Materials and Products, Standard Method of Test for 264 | 1995 | Standard Method of Test of Heat and Visible Smoke Release Rates for Materials and Products Using an Oxygen Consumption Calorimeter 264A | 1994 | Method of Test for Heat Release Rates for Upholstered Furniture Components or Composites and Mattresses Using an Oxygen Consumption Calorimeter 265 1 | 2002 | Standard Methods of Fire Tests for Evaluating Room Fire Growth Contribution of Textile Coverings on Full Height Panels and Walls 268 1 | 2001 | Standard Test Method for Determining Ignitibility of Exterior Wall Assemblies Using a Radiant Heat Energy Source 269 1 | 2000 | Standard Test Method for Developing Toxic Potency Data for Use in Fire Hazard Modeling 291 1 | 2002 | Recommended Practice for Fire Flow Testing and Marking of Hydrants 295 | 1991 | Standard for Wild Fire Control 297 | 1995 | Guide on Principles and Practices for Communications Systems 299 | 1991 | Standard for Protection of Life and Property from Wildfire 318 1 | 2006 | Standard for the Protection of Semiconductor Fabrication Facilities 325 | 1994 | Guide to Fire Hazard Properties of Flammable Liquids, Gases, and Volatile Solids 328 | 1992 | Recommended Practice for the Control of Flammable and Combustible Liquids and Gases in Manholes, Sewers, and Similar Underground Structures 329 1 | 2005 | Recommended Practice for Handling Releases of Flammable and Combustible Liquids and Gases 419 | 1992 | Guide for Master Planning Airport Water Supply Systems for Fire Protection 423 1 | 2004 | Standard for Construction and Protection of Aircraft Engine Test 424 1 | 2004 | Guide for Airport/Community Emergency Planning 491M | 1991 | Manual of Hazardous Chemical Reactions 497 1 | 2004 | Recommended Practice for the Classification of Flammable Liquids, Gases, or Vapors and of Hazardous (Classified) Locations for Electrical Installations in Chemical Process Areas 497M | 1991 | Manual for Classification of Gases, Vapors, and Dusts for Electrical Equipment in Hazardous (Classified) Locations 499 1 | 2004 | Recommended Practice for the Classification of Combustible Dusts and of Hazardous (Classified) Locations for Electrical Installations in Chemical Process Areas 512 | 1994 | Standard for Truck Fire Protection 555 1 | 2004 | Guide on Methods for Evaluating Potential for Room Flashover 600 1 | 2005 | Standard on Industrial Fire Brigades 601 1 | 2005 | Standard for Security Service in Fire 701 1 | 2004 | Standard Methods of Fire Tests for Flame Propagation of Textiles and Films 705 1 | 2003 | Recommended Practice for a Field Flame Test for Textiles and Films 801 1 | 2003 | Standard for Facilities Handling Radioactive Materials 802 | 1993 | Recommended Practice for Fire Protection for Nuclear Research and Production Reactors 803 | 1993 | Standard for Fire Protection for Light Water Nuclear Power Plants 804 1 | 2006 | Standard for Fire Protection for Advanced Light Water Reactor Electric Generating Plants 805 1 | 2006 | Performance-Based Standard for Fire Protection for Light Water Reactor Electric Generating Plants 820 1 | 2003 | Standard for Fire Protection in Wastewater Treatment and Collection Facilities 850 1 | 2005 | Recommended Practice for Fire Protection for Electric Generating Plants and High Voltage Direct Current Converter Stations 851 1 | 2005 | Recommended Practice for Fire Protection for Hydroelectric Generating Plants 901 1 | 2006 | Standard Classifications for Incident Reporting and Fire Protection Data 914 1 | 2001 | Code for Fire Protection of Historic Structures 1141 | 2003 | Standard for Fire Protection in Planned Building Groups 1600 1 | 2004 | Standard on Disaster/Emergency Management and Business Continuity Programs
APPENDIX D
NFPA Publications For Guidance
Alphabetical Listing
The following Standards, Recommendations, Recommended Practices, Manuals, Guides and Model Laws are included here for reference and guidance in the application of the State of Delaware Fire Prevention Rules and Regulations when a particular problem is not otherwise covered by a Code, Standard, or Law Provision. The Fire Marshal may use the provisions of these Standards, Recommendations, Recommended Practices, Manuals, Guides and Model Laws as appropriate criteria for meeting the intent of the State of Delaware Fire Prevention Rules and Regulations in those cases.
NFPA NO. | DATE OF PUBLI-CATION | TITLE 423 1 | 2004 | Aircraft Engine Test, Standard for Construction and Protection of 424 1 | 2004 | Airport/Community Emergency Planning, Guide for 419 | 1992 | Airport Water Supply Systems for Fire Protection, Guide for Master Planning 101A 1 | 2004 | Alternative Approaches to Life Safety, Guide on 231E | 1996 | Baled Cotton, Recommended Practice for the Storage of 85 1 | 2004 | Boiler and Combustion Systems Hazards Code 251 1 | 2006 | Building Construction and Materials, Standard Methods of Tests of Fire Resistance of 259 1 | 2003 | Building Materials, Standard Test Method for Potential Heat of 255 1 | 2006 | Building Materials, Standard Method of Test of Surface Burning Characteristics of 491M | 1991 | Chemical Reactions, Hazardous, Manual of 49 | 1994 | Chemicals Data, Hazardous 97 | 1996 | Chimneys, Vents, and Heat-Producing Appliances, Standard Glossary of Terms Relating to 260 1 | 2003 | Cigarette Ignition Resistance of Components of Furniture, Standard Methods of Tests and Classification System for 297 | 1995 | Communications Systems, Guide on Principals and Practices for 1600 1 | 2004 | Standard on Disaster/Emergency Management and Business Continuity Programs 252 1 | 2003 | Door Assemblies, Standard Methods of Fire Tests of 497M | 1991 | Electrical Equipment in Hazardous (Classified) Locations, Manual for Classification of Gases, Vapors, and Dusts for 70B | 2006 | Electrical Equipment Maintenance, Recommended Practice for 850 1 | 2005 | Electric Generating Plants and High Voltage Direct Current Converter Stations, Recommended Practice for Fire Protection for 804 1 | 2006 | Electric Generating Plants, Standard for Fire Protection for Advanced Light Water Reactor 805 1 | 2006 | Reactor Electric Generating Plants, Performance-Based Standard for Fire Protection for Light Water 497 1 | 2004 | Electrical Installations in Chemical Process Areas, Recommended Practice for the Classification of Flammable Liquids, Gases, or Vapors and of Hazardous (Classified) Locations for 499 1 | 2004 | Recommended Practice for the Classification of Combustible Dusts and of Hazardous (Classified) Locations for Electrical Installations in Chemical Process Areas 70E 1 | 2004 | Electrical Safety Requirements for Employee Workplaces, Standard for 80A 1 | 2001 | Exterior Fire Exposures, Recommended Practice for Protection of Buildings from 268 1 | 2001 | Exterior Wall Assemblies, Standard Test Method for Determining Ignitibility of, Using a Radiant Heat Energy Source 705 1 | 2003 | Field Flame Test for Textiles and Films, Recommended Practice for a 269 1 | 2000 | Fire Hazard Modeling, Standard Test Method for Developing Toxic Potency Data for Use in 329 1 | 2005 | Flammable and Combustible Liquids and Gases, Recommended Practice for Handling Releases of 328 | 1992 | Flammable and Combustible Liquids and Gases in Manholes, Sewers, and Similar Underground Structures, Recommended Practice for the Control of 325 | 1994 | Flammable Liquids, Gases, Volatile Solids, Guide to Fire Hazard Properties of 555 1 | 2004 | Flashover, Room, Guide on Methods for Evaluating Potential for 253 1 | 2006 | Floor Covering Systems Using a Radiant Heat Energy Source, Standard Method of Test for Critical Radiant Flux of 46 | 1996 | Forest Products, Recommended Safe Practice for Storage of 263 | 1994 | Heat and Visible Smoke Release Rates for Materials and Products, Standard Method of Test for 264 | 1995 | Heat and Visible Smoke Release Rates for Materials and Products Using an Oxygen Consumption Calorimeter, Standard Method of Test for 914 1 | 2001 | Historic Structures, Code for Fire Protection of 291 1 | 2002 | Hydrants, Recommended Practice for Fire Flow Testing and Marking of 851 1 | 2005 | Hydroelectric Generating Plants, Recommended Practice for Fire Protection for 99B 1 | 2005 | Hypobaric Facilities, Standard for 901 1 | 2006 | Incident Reporting and Fire Protection Data, Standard Classifications for 261 1 | 2003 | Ignition by Smoldering Cigarettes, Standard Method of Test for Determining Resistance of Mock-Up Upholstered Furniture Material Assemblies to 600 1 | 2005 | Industrial Fire Brigades, Standard on 115 1 | 2003 | Laser Fire Protection, Standard for 11C | 1995 | Mobile Foam Apparatus, Standard for 803 | 1993 | Nuclear Power Plants, Light Water, Standard for Fire Protection for 802 | 1993 | Nuclear Research and Production Reactors, Recommended Practice 53 1 | 2004 | Oxygen Enriched Atmospheres, Guide on Fire Hazards in 43D | 1994 | Pesticides, Code for the Storage of 1141 1 | 2003 | Planned Building Groups, Standard for Fire Protection in 801 1 | 2003 | Radioactive Materials, Standard for Facilities Handling 232 1 | 2000 | Standard for Protection of Records 203 | 1995 | Roof Coverings and Roof Deck Construction, Guide on 256 1 | 2003 | Roof Coverings, Standard Methods of Fire Tests of 601 1 | 2005 | Security Service in Fire Loss Prevention, Standard for 318 1 | 2006 | Semiconductor Fabrication Facilities, Standard for the Protection of 105 1 | 2003 | Smoke Door Assemblies, Standard for the Installation of 204 1 | 2002 | Smoke and Heat Venting, Standard for 258 1 | 2001 | Smoke Generation of Solid Materials, Standard Research Test for Determining 77 1 | 2003 | Static Electricity, Recommended Practice on 265 1 | 2002 | Standard Methods of Fire Tests for Evaluating Room Fire Growth Contribution of Textile Coverings on Full Height Panels and Walls 701 1 | 2004 | Textiles and Films, Standard Methods of Fire Tests for Flame Propagation of 130 1 | 2003 | Transit Systems, Fixed Guideway, Standard for 512 | 1994 | Truck Fire Protection, Standard for 264A | 1994 | Upholstered Furniture Components or Composites and Mattresses Heat Release Rates for 68 1 | 2002 | Venting of Deflagrations, Guide for 820 1 | 2003 | Wastewater Treatment and Collection Facilities, Standard for Fire Protection in 295 | 1991 | Wild Fire Control, Standard for 299 | 1991 | Wildfire, Standard for Protection of Life and Property from 262 1 | 2002 | Wires and Cables for Use in Air-Handling Spaces, Standard Method of Test for Flame Travel and Smoke of 257 1 | 2000 | Window and Glass Block Assemblies, Standard on Fire Test for
Appendix E
Permits, Licenses, and Other Fees
Amusement Ride Fees. The cost of any fee for amusement rides shall be $100 per year, not to exceed a total of $400. ( 16 Del.C. §6403 )
Blaster’s License. The cost of a Blaster’s License shall be $100 per year. ( 16 Del.C. §7107(b) ).
Certificate Of Inspection For Fire Alarm Signaling Systems Fees. The cost of an Annual Certificate of Inspection shall be as follows:
All fire alarm signaling systems - $25 per system.
( 16 Del.C. §6607(g)(5)c. ).
Explosives Storage. The cost of a license to store explosives shall be $100 per year. ( 16 Del.C. §7101(b) ).
Fire Alarm Central Station, Remote Station, or Monitoring Service or Company License. The cost of an annual license for a Fire Alarm Central Station, Remote Station, or Monitoring Service or Company shall be $100.
Fire Alarm Signaling System Company License. The cost of an annual license for a Fire Alarm Signaling System Company shall be $100.
Fire Alarm Signaling System Certificate Holder. The cost of an annual certificate for a CERTIFICATE HOLDER of a Fire Alarm Signaling System Company shall be $100.
Fire Suppression System Company License. The cost of an annual license for a Fire Suppression System Company shall be $100.
Fire Suppression System Certificate Holder. The cost of an annual certificate for a CERTIFICATE HOLDER of a Fire Suppression System Company shall be $100.
In-House License Fees. Where a Fire Alarm Signaling System In-House or Fire Suppression System In-House License is issued, a maximum of $100.00 per Fire Alarm Signaling or Fire Suppression System shall be charged for each system serviced by the system owner. ( 16 Del.C. §6607(g)(5)a. )
Licenses/Permits That Require An On-Site Inspection Prior To Issuing A License Or Permit. $100 per license or permit. ( 16 Del.C. §6607(g)(5)c. ).
Licenses/Permits That Do Not Require An On-Site Inspection Prior To Issuing A License Or Permit. $50 per license or permit. ( 16 Del.C. §6607(g)(5)c. ).
License To Service Portable Fire Extinguishers. The cost of a License to service portable fire extinguishers shall be $100 per year. ( 16 Del.C. §6607(g)(5)b. ).
Plan Review User Fee Schedule. The State Fire Marshal, under the provisions 16 Del.C. §6607(g)(1) - §6607(g)(4) , hereby establishes the below listed Plan Review User Fee to be paid by the submitter of plans to the State of Delaware, Office of State Fire Marshal.
(a) Effective July 1, 2009: .007/.003
7/10 of 1% of construction costs up to the first million dollars of construction costs.
3/10 of 1% of construction costs in excess of 1 million dollars of construction costs.
Minimum Plan Review Fee of $150 on all plans.
(b) Sub-Division Plan Reviews
1. Major Subdivisions - $150
2. Minor Subdivisions - $150
(c) Special Fees For Warehouses
When calculating the fee schedule for warehouses and similar low use buildings, the submitter shall have the choice of using the fee schedule listed in A and B above or, he may use the following calculation:
Gross Square Footage X $30 = Construction Cost
Then apply the percentages listed in A and B above to this calculated construction cost.
(d) Revision Of Fees.
The fees as authorized by 16 Del.C. §6607 shall be the maximum allowed by the State Fire Prevention Commission, and shall be reviewed every 2 years.
Detailed Fee List
Annual Certificate/License Required
Annual Certificate/License | Annual Fee Covered Malls | $100 Explosives | $100 Fire Alarm Central Station, Remote Station, or Monitoring Service or Company License | $100 Fire Alarm Certificate Holder | $100 Fire Alarm Certificate of Inspection per System | $25 Fire Alarm Company License | $100 Fire Extinguisher License | $100 Fire Suppression Certificate Holder | $100 Fire Suppression Certificate of Inspection per System | $25 Fire Suppression Company License | $100 Fireworks Shooters | $100 Flammable/Comustible Liquids | $100 In-House Fire Alarm Signaling System License (per system) | $100 In-House Fire Suppression System License (per system) | $100 Liquified Petroleum Gas or Dispensing | $100 Places of Assembly License | $100 Public Accommodations (Hotel, Motel, Bed and Breakfast, Rooming and Lodging, and Boarding Houses) | $100 Food Truck License | $50 Outdoor Tire Storage | $100 Permit Required For Single Event Single Event | Event Fee Amusement Rides (Not to exceed $400) | $100 per ride Amusement Attraction | $100 Bowling Lanes | $100 Burning | $100 Exhibits, Craft, Trade Shows | $100 Explosives Single Event | $100 Fireworks Public Display and Transportation | $100 Impairment of Fire Protection | $50 Place of Assembly Special Events | $100 Tent Permits | $100 Fun House or Haunted House | $100
29 DE Reg. 931 (05/01/26)
Appendix F
Table 1
Owner Performed Testing, Inspection, and Maintenance of Fire Suppression Systems As Required by Regulation 703, Chapter 1 and the Standard for the Inspection, Testing, and Maintenance of Water-Based Fire Protection Systems NFPA 25, 2008 Edition
This brief summary of periodic tests, inspections, and maintenance is not all inclusive, and, to assist in the performance of these services, the user is advised to purchase the applicable documents from NFPA (1-800-344-3555). These periodic tests, inspections, and maintenance may be performed by the owner or the owner's maintenance staff. A log book must be maintained by the owner for each system. The log book must include the date the service was performed, the type of service performed, and the person performing the service. An asterisk (*) denotes servicing which must be performed at least annually (once a year) by a company licensed by the Office of State Fire Marshal, Licensing Division, (302) 739-4394.
Item | Activity | Frequency | Service | Section # General Gauges, Pressure | Inspection | * Monthly | Wet System | §5.2.4.1 * Weekly | Dry, Preaction, Deluge Systems | §5.2.4.2 Control Valves | Inspection | * Weekly | Valves (not supervised or secured) | §12.3.2.1 * Monthly | supervised and secured Valves | §12.3.2.1.1 Testing | * Annual | Operated though its full range | §12.3.3.1 Alarm Devices | Testing | * Semiannual | Vane type devices | §5.3.3. Testing | * Quarterly | Wet System: flow thru inspectors test | §5.3.3.3 Dry/Preaction/Deluge: use bypass | §5.3.3.5 Fire Dept Conn | Inspection | * Quarterly | Visible, accessible, operating condition | §12.7 Alarm Valves | Inspection | * Monthly | Free of damage, leakage, in proper position | §12.4.1.1 Backflow Prevention Assemblies Reduced Pressure | Inspection | * Weekly | Differential sensing valve relief port | §12.6.1.2 R.P. Detector | Inspection | * Weekly | Differential sensing valve relief port | §12.6.1.2 Main Drain | Testing | * Quarterly | Test to check condition of water supply | §12.6.1 Water Flow Alarm | Testing | * Quarterly | Test in accordance with manufacturer | §12.2.7 Preaction/Deluge Valves Enclosure | Inspection | Daily | In cold weather only, maintain 40° | §12.4.3.1 Valve Exterior | Inspection | * Monthly | Free of damage, leakage, trim valves set properly, electrical components operational | 12.4.3.1.6 Dry Valves/Quick-Opening Devices Enclosure | Inspection | Daily | In cold weather only, maintain 40° | §12.4.4.1.1 Valve Exterior | Inspection | * Monthly | Free of damage, leakage, trim valves set properly, electrical components operational | §12.4.4.1.3 Pressure Regulating and Relief Valves Sprinkler System | Inspection | * Quarterly | Valves open, no leakage, proper pressure | §12.5.1.1 Hose Connection | Inspection | * Quarterly | Valves okay, no leakage, all parts present | §12.5.2.1 Hose Rack | Inspection | * Quarterly | Valves okay, no leakage | §12.5.3.1 Fire Pump Relief Valves Circulation | Inspection | * Weekly | Water flows thru valve at churn | §12.5.6.1 Pressure | Inspection | * Weekly | Water flows thru valve at rated pressure | §12.5.6.2 Standpipes Piping | Inspection | * Quarterly | All parts present, operable, in good condition | §6.2.1 Inspection | Monthly | See Table 6.1 | §6.2.1 Hose Valve | Inspection | * Quarterly | All parts present & in good condition | §6.2.1 Outlets | Inspection | Monthly | See Table 6.1 | §6.2.1 Fire Pumps Pump House | Inspection | * Weekly | In cold weather, see Tables 8.1 | §8.1 System | Inspection | * Weekly | See Table 8.5.3 | §8.2 Pump Operation No Flow | Testing | * Weekly | Electric: auto start and run 10 minutes min | §8.3.2.1 Diesel: auto start and run 30 minutes min | §8.3.2.1 Foam Water Sprinkler System Discharge Devices | Inspection | * Monthly | No damage/corrosion, in place w/proper aim | §11.2.5 Strainer | Inspection | * Quarterly | Blow-down Valve, blankets/screens | §11.2.9.2 Drainage | Inspection | * Quarterly | Free of blockage, embankments good repair | §11.2.8 Fittings/Piping | Inspection | * Quarterly | No damage/corrosion/missing parts | §11.2.3 Hangers/Support | Inspection | * Quarterly | No damage/corrosion, attachments secure | §11.2.4 Foam Water Sprinkler Proportioning System Standard Pressure | Inspection | * Monthly | No corrosion, ball drip valves free/opened | §11.2.9.5.1 Bladder Tank | Inspection | * Monthly | No corrosion, water control valves in position | §11.2.9.5.2 Line Proportioner | Inspection | * Monthly | No corrosion, pressure vacuum vent operable | §11.2.9.5.3 Standard Balanced | Inspection | * Monthly | Pressure vacuum vent, sensing lines, gauges | §11.2.9.4 In-Line Balanced | Inspection | * Monthly | Pressure vacuum vent, sensing lines, gauges | §11.2.9.5.5 Orifice Plate | Inspection | * Monthly | Pressure vacuum vent, sensing lines, gauges | §11.2.9.5.6 Private Fire Service Mains Hose House | Inspection | Quarterly | Accessible, free of damage, all parts present | §7.2.2.7 Maintenance | Annually | Hoses and all parts in usable condition | §7.4.5 Hydrant House | Inspection | Quarterly | Accessible, free of damage, all parts present | §7.2.2.7 Maintenance | Annually | Hoses and all parts in usable condition | §7.4.5 Hydrant: Wall/Dry | Inspection | Annually | Accessible, no water in barrel, operable | §7.2.2.4 Testing | Annually | Flow Test, minimum one minute | §7.3.2 Maintenance | Annually | Lubricate stems, caps, plugs, threads | §7.4.3.1 Hydrant: Wet | Inspection | Annually | Accessible, free of damage, operable | §7.2.2.5 Testing | Annually | Flow Test, minimum one minute | §7.3.2 Maintenance | Annually | Lubricate stems, caps, plugs, threads | §7.4.3.1 Monitor Nozzle | Inspection | 2 Times/Year | Free of damage, no leakage, no corrosion | §7.2.2.6 Testing | Annually | Full range oscillation and movement | §7.3.3 Testing | Annually | When attached to hydrants, per NFPA 25 | §7.3.3.1 Maintenance | Annually | Lubricate | §7.4.4 Mainline Strainer | Inspection | Annually | Clean, free of damage and corrosion | §7.2.2.3 Maintenance | Annually | Clean annually & after each use | §7.4.2 Piping: Exposed | Inspection | Annually | Free of damage, no leakage, no corrosion | §7.2.2.1 Testing | Every 5 Years | Fire Flow Test for internal conditions | §7.3.1 Underground | Testing | Every 5 Years | Fire Flow Test for internal conditions | §7.3.1 Water Spray Fixed System Drainage | Inspection | Monthly | Free of blockage, embankments good repair | §10.2.8 Fittings/Piping | Inspection | * Quarterly | No damage/corrosion/rust/missing parts | §10.2.4 Hangers/Support | Inspection | * Quarterly | No damage/corrosion/rust/missing parts | §10.2.4 Heat/Valve Room | Inspection | * Monthly | Maintain 40° F | §10.2.1.5 Inspection | Weekly | In cold weather, inspect daily | §10.2.1.5 Nozzles | Inspection | * Monthly | No damage/corrosion, in place w/proper aim | §10.2.1 Strainers | Inspection | * Per Mfr | Flushed clear after each operation or test | §10.2.7 Water Storage Tanks Condition/Level | Inspection | Monthly | In cold weather only | §9.2.1 Level | Maintenance | Monthly | regardless if water level alarm is provided | §9.3 Level Alarm | Testing | * 2 Times/Year | High and Low water level alarms tested | §9.3.5 Heating System | Inspection | Daily | In cold weather only | §9.2.6.6 Temperature | Inspection | Daily | Only in cold weather, maintain 40 deg. F | §9.2.3.2 Low Alarm | Testing | * Monthly | Where provided, test in cold weather | §9.3.3 High Alarm | Testing | Monthl y | In cold weather, test limit switches | §9.3.4 Air Pressure | Inspection | * Monthly | In pressure tanks | §9.2.2.2 Tank Exterior | Inspection | * Quarterly | Free of damage, no leakage, sound structure | §9.2.5.1 Tank Area/Yard | Inspection | Quarterly | Free of combustibles, corrosion, erosion, ice | §9.2.5.2 Hoops/Grillage | Inspection | Annually | In wooden tanks, no damage/deterioration | §9.2.5.4 Tank Surface | Inspection | Annually | Paint/Coat/Insulation no damage/deterioration | §9.2.5.5 Maintenance | Per Mfr | Repaint steel tanks per manufacturer | §9.4.4 Tank Support | Maintenance | * Per Mfr | Embankment Supported Rubberized Fabric | §9.4.6 Expansion Joints | Inspection | * Annually | Where provided, no leaks, no cracks | §9.2.5 Sediment | Maintenance | * 2 Times/Year | Drain and/or flush tank | §9.4.5
Inspection: A visual examination to verify an item is in operating condition and free of physical damage.
Testing: A procedure used to determine the status of a system operating as intended by conducting physical checks.
Maintenance: Work performed to keep equipment operable or to make repairs.
* Servicing may be performed by an owner, but must be performed at least annually by a licensed company.
Appendix F
Table 2
Licensed Company Required
Testing, Inspection, and Maintenance of Fire Suppression Systems As Required by Part III, Chapter 1 and the Standard for the Inspection, Testing, and Maintenance of Water-Based Fire Protection Systems NFPA 25, 2002 Edition
This brief summary of periodic tests, inspections, and maintenance is not all inclusive, and, to assist in the performance of these services, the user is advised to purchase the applicable documents from NFPA (1-800-344-3555). These periodic services must be performed by a company licensed by the Office of State Fire Marshal, Licensing Division, (302) 739-4394. A log book must be maintained by the licensed company for each system. The log book must include the date the service was performed, the type of service performed, and the person performing the service. An asterisk (*) denotes servicing which may be performed by an owner, but must be performed at least annually (once a year) by a licensed company. A licensed company must forward a Certificate of Inspection to the Office of State Fire Marshal within 30 days of the annual inspection.
Item | Activity | Frequency | Service | Section # General Gauges, Pressure | Inspection | * Monthly | Wet System | §5.2.4.1 * Weekly | Dry, Preaction, Deluge Systems | §5.2.4.2 Testing | Every 5 Years | Calibration Test | §5.3.2 Control Valves | Inspection | * Weekly | Valves (not supervised or secured) | §12.3.2.1 * Monthly | Supervised/Secured Valves & Tamper Sws | §12.3.2.1 Testing | Annually | Operate Valve - full range of motion | §12.3.3 Maintenance | Annually | Oil/grease valve stems, open & close | §12.4.1.3 Alarm Devices | Inspection | * Quarterly | Free of damage/all connections secure | §5.3.3.2 Testing | * Quarterly | Wet System: flow thru inspectors test | §5.3.3.3 Dry/Preaction/Deluge: use bypass | §5.3.3.5 Hangars | Inspection | Annually | Inspect for damaged or loose hangars | §5.2.3 Piping | Inspection | Annually | No damage, leakage, corrosion, etc. | §5.2.2 Sprinklers/Standard | Inspection | Annually | No corrosion, obstructions, paint, etc | §5.2.1.1 Testing | After 50 Years | Submit samples to lab for test | §5.3.1.1.1.1 Testing | +10 Years | Repeat Every 10 years thereafter Fast Response | Testing | After 20 Years | Submit samples to lab for test | §5.3.1.1.1.2 +10 Years | Repeat Every 10 years thereafter High Temp | Testing | After 5 Years | Submit samples to lab for test | §5.3.1.1.1.3 FD Connection | Inspection | * Quarterly | Visible, accessible, operating condition | §12.7. Alarm Valves | Inspection | * Monthly | Free of damage, leakage, in proper position | §12.4.1.1 Inspection | Every 5 Years | Internal inspection | §12.4.1.2 Check Valves | Inspection | Every 5 Years | Internal inspection | §12.4.2.1 Backflow Prevention Assemblies Reduced Pressure | Inspection | * Weekly | Differential sensing valve relief port | §12.6.1.2 R.P. Detector | Inspection | * Weekly | Differential sensing valve relief port | §12.6.1.2 Entire Assembly | Testing | Annually | Test in accordance with AHJ procedures | §12.6.2, Main Drain | Testing | * Quarterly | Test to check condition of water supply | §12.2.6 Water Flow Alarm | Testing | * Quarterly | Test in accordance with manufacturer | §12.2.7 Preaction/Deluge Valves Valve Exterior | Inspection | * Monthly | No damage, trim valves set properly, etc | §12.4.1.3.6 Valve Interior | Inspection | Annually | Internal inspection | §12.4.1.3.7 Strainers/Filters | Inspection | Every 5 Years | Internal inspection | §12.4.3.1.8 Priming Water | Testing | Quarterly | Test levels per manufacturer’s instructions | §12.4.3.2.1 Low Press Alarm | Testing | Quarterly | Test per manufacturer’s instructions | §12.4.3.2.10 Full Flow Test | Testing | Annually | In warm weather, test per manufacturer | §12.4.3.2.2 Valves | Testing | Annually | During Full Flow Test, clean & repair interior | §12.4.3.3.2 Dry Valves/Quick-Opening Devices (Q.O.D.) Valve Exterior | Inspection | * Monthly | No damage, trim valves set properly, etc | §12.4.4.1.4 Valve Interior | Inspection | Annually | Internal inspection | §12.4.4.1.5 Strainers/Filters | Inspection | Every 5 Years | Internal Inspection | §12.4.4.1.6 Priming Water | Testing | Quarterly | Test levels per manufacturer’s instructions | §12.4.4.2.1 Low Air Alarm | Testing | Quarterly | Test per manufacturer’s instructions | §12.4.4.2.6 Q.O.D. | Testing | Quarterly | Test per manufacturer’s instructions | §12.4.4.2.4 Maintenance | Annually | During Trip Test, clean & repair interior | §12.4.4.3.2 Trip Test | Testing | Annually | In warm weather, test w/valve partially open | §12.4.4.2.2 Full Flow Test | Testing | Every 3 Years | In warm weather, test w/valve fully open | §12.4.4.2.2.2 Pressure Regulating and Relief Valves Sprinkler System | Inspection | * Quarterly | Valves open, no leakage, proper pressure | §12.5.1.1 Testing | Annually | Flow test on each valve | §12.5.1.2 Hose Connection | Inspection | * Quarterly | Valves okay, no leakage, all parts present | §12.5.2.1 Hose Rack | Inspection | * Quarterly | Valves okay, no leakage | §12.5.3.1 Fire Pump Relief Valves Circulation | Inspection | * Weekly | Water flows thru valve at churn | §12.5.6.1 Pressure | Inspection | * Weekly | Water flows thru valve at rated pressure | §12.5.6.2 Circulation | Testing | Annually | Valve closes per manufacturer's listing | §12.5.6.1.2 Pressure Relief | Testing | Annually | Valve adjusted during Annual Fire Pump Test | §12.5.6.2.2 Hose Connections | Testing | Every 5 Years | Full Flow Test per manufacturer | §12.5.2.2 Hose Rack | Testing | Every 5 Years | Full Flow Test per manufacturer | §12.5.3.2 Obstruction | Maintenance | Every 5 Years | Investigate to ensure piping is free of debris | Table 5.1 Anti-Freeze | Testing | Annually | Measure specific gravity of solution | §5.3.4 Standpipes Hose Valve Outlet | Inspection | * Quarterly | All parts present & in good condition | §6.2.1 Piping | Inspection | * Quarterly | All parts present, operable, in good condition | §6.2.1 Cabinet | Inspection | Annually | All parts present, operable, in good condition | §6.2.1 Hose | Inspection | Annually | All parts present, operable, in good condition | §6.2.1 Testing | Every 5 Years | Per NFPA 1962 | §6.3 Testing | Every 3 Years | Per NFPA 1962 | §6.3 Hose Storage | Inspection | Annually | All parts present, operable, in good condition | §6.2.1 Testing | Annually | Test for smooth operation | §6.3 Hose Nozzle | Testing | Annually | Test for smooth operation | §6.3 Hydrostatic | Testing | Every 5 Years | 200 psi for 2 hours | §6.3 Water Supply | Testing | Every 5 Years | Flow designed volume, pressure @ remote | §6.3.1.1 Fire Pumps Pump House | Inspection | * Weekly | In cold weather, see Tables 8.1 & 8.5.3 | §8.2.2 System | Inspection | * Weekly | See Table 8.5.3 | §8.2.2 Pump Operation No Flow | Testing | * Weekly | Electric: auto start & run 10 minutes min | §8.3.1.2 Diesel: auto start and run 30 minutes min | §8.3.1.3 Flow | Testing | Annually | Annual Flow Test | §8.3.3 Hydraulics, Transmission Electrical, Controller, Motor, and Diesel Parts | Maintenance | Annually | Establish preventive maintenance program, per manufacturer’s instructions, on all components of the pump assembly | §8.5.3 Foam Water Sprinkler System Discharge Devices | Inspection | * Monthly | No damage/corrosion, in place w/proper aim | §11.2.5 Strainer | Testing | Annually | Discharge patterns/proper location/position | §11.3.3.6 Inspection | * Quarterly | Blow-down Valve, blankets/screens | §11.2.7 Testing | Annually | After each test/remove/clean baskets/screens | §11.2.7.2 Maintenance | Annually | Inspect and clean after each test | §11.4 Drainage | Inspection | * Quarterly | Free of blockage, embankments good repair | §11.2.9 Fittings/Piping | Inspection | * Quarterly | No damage/corrosion/missing parts | §11.2.3 Hangers/Support | Inspection | * Quarterly | No damage/corrosion, attachments secure | §11.-2.4 Complete System | Testing | Annually | Full Automatic & Manual Operational Test | §11.3.3 Concentrate Sample | Testing | Annually | During Annual Test refractometric check | §11.3.6 Maintenance | Annually | During Annual Test, submit sample per mfr | §11.2.10 Pump | Maintenance | Monthly | Pump run, circulate foam, maintenance/mfr | §11.4.6 & 11.4.7 Foam Water Sprinkler Proportioning System Standard Pressure | Inspection | * Monthly | No corrosion, ball drip valves free/opened | §11.2.9.5.1 Maintenance | Every 5 Yrs | Disassemble/clean/reassemble ball drip valves | §11.4.3A Maintenance | Every 10 Yr | Drain/flush tank, hydro test | §11.4.3BC Bladder Tank | Inspection | * Monthly | No corrosion, water control valves in position | §11.2.9.5.2 Maintenance | Every 10 Yr | Remove/clean sight glass, hydro test | §11.4.4 Line Proportioner | Inspection | * Monthly | No corrosion, pressure vacuum vent operable | §11.2.9.5.3 Maintenance | Every 10 Yr | Drain/flush tank, tank/piping corrosion check | §11.4.5 Standard Balanced | Inspection | * Monthly | Pressure vacuum vent, sensing lines, gauges | §11.2.9.5.4 Maintenance | Every 5 Yrs | Flush valves, pump/drive train/driver per mfr | §11.4.6 In-Line Balanced | Inspection | * Monthly | Pressure vacuum vent, sensing lines, gauges | §11.2.9.5.5 Maintenance | Every 5 Yrs | Flush valves, pump/drive train/driver per mfr | §11.4.7BC Maintenance | Every 10 Yr | Internally inspect tank for corrosion | §11.4.7.D Orifice Plate | Inspection | * Monthly | Pressure vacuum vent, sensing lines, gauges | §11.2.9.5.6 Water Spray Fixed System Fittings/Piping | Inspection | * Monthly | No damage/corrosion/rust/missing parts | §10.2.1&10.2.4 Hangers/Support | Inspection | * Monthly | No damage/corrosion/rust/missing parts | §10.2.4.2 Heat/Valve Room | Inspection | * Monthly | Maintain 40° F | §10.2.1.5 Nozzles | Inspection | * Monthly | No damage/corrosion, in place w/proper aim | §10.2.1/10.2.5 Strainers | Inspection | * Per Mfr | Flushed clear after each operation or test | §10.2.7 Operational Test | Testing | Annually | Full Manual & Automatic Operational Test | §T 10.1 Water Storage Tanks Water Level | Inspection | * Quarterly | Where a water level alarm is provided | §9.2.1 Level Alarm | Testing | * 2 Times/Year | High and Low water level alarms tested | §9.33.5 Level Indicators | Testing | Every 5 Years | Accuracy and freedom of movement | §9.3.1 Thermostats | Testing | Frequency per manufacturer’s specifications | §9.3.2 Low Temp Alarm | Testing | * Monthly | Where provided, test in cold weather | §9.3.3 Air Pressure | Inspection | * Monthly | In pressure tanks | §9.2.2 Tank Exterior | Inspection | * Quarterly | Free of damage, no leakage, sound structure | §9.2.5.1 Tank Support | Maintenance | * Per Mfr | Embankment Supported Rubberized Fabric | §9.4.6 Expansion Joints | Inspection | * Annually | Where provided, no leaks, no cracks | §9.2.5.3 Interior | Inspection | Every 5 Years Every 3 Years | Free of damage Pressure tanks, & steel tanks w/out corrosion protection | §9.2.6.1.1 §9.2.6.1.2 Sediment, Drain | Maintenance | * 2 Times/Year | Drain and/or flush tank | §9.4.5 Cathode Protection | Maintenance | Annually | Where provided, per manufacturer Drain Valves | Maintenance | Annually | Cycled fully open and closed Vent Screens | Maintenance | Annually | Clean
Inspection : A visual examination to verify an item is in operating condition and free of physical damage.
Testing: A procedure used to determine the status of a system operating as intended by conducting physical checks.
Maintenance: Work performed to keep equipment operable or to make repairs.
* Servicing may be performed by an owner, but must be performed at least annually by a licensed company.
Appendix F - Table 3
Owner Performed
Testing, Inspection, and Maintenance of Fire Alarm Signaling Systems
as Required by Regulation 703, Chapter 1 and the National Fire Alarm Code, NFPA 72, 2007 Edition
This brief summary of periodic tests, inspections, and maintenance is not all inclusive, and, to assist in the performance of these services, the user is advised to purchase the applicable documents from NFPA (1-800-344-3555). These periodic tests, inspections, and maintenance may be performed by the owner or the owner’s maintenance staff. A log book must be maintained by the owner for each system. The log book must include the date the service was performed, the type of service performed, and the person performing the service. An asterisk (*) denotes servicing which must be performed at least annually (once a year) by a company licensed by the Office of State Fire Marshal, Licensing Division, (302) 739-4394.
Item | Activity | Frequency | Service | Section #/Table Control Equipment Fire Alarm Systems Unmonitored for Alarm Supervisory, Trouble Signals Fuses | Inspection | *Weekly | No damage or missing parts | Table 10.3.1 Interfaced Equip Inspection | Inspection | *Weekly | Wiring connections secure/No damage | Table 10.3.1 Lamps and LEDs Inspection | Inspection | *Weekly | All lamps and LEDs illuminated | Table 10.3.1 Primary (Main) Power Supply | Inspection | *Weekly | Secured/Marked/No damage | Table 10.3.1 Batteries Lead-Acid | Inspection | *Monthly | Electrolyte level/connections, No corrosion | Table 10.3.1 Nickel-Cadmium | Inspection | *2 Times/Year | No corrosion/leakage, Connections tight | Table 10.3.1 Primary (Dry Cell) | Inspection | *Monthly | No corrosion/leakage, Connections tight | Table 10.3.1 Sealed Lead-Acid | Inspection | *2 Times/Year | No corrosion/leakage, Connections tight | Table 10.3.1 Transient Suppressors Lightning Protection Equipment Inspection | *2 Times/Year | Per mfr/After every lightning strikes/storms | Table 10.3.1 and NFPA 780 Remote Annunciators Inspection | *2 Times/Year | Secured/No damage or missing parts | Table 10.3.1 Initiating Devices Air Sampling | Inspection | *2 Times/Year | Secured/No damage or missing parts | Table 10.3.1 Duct Detectors | Inspection | *2 Times/Year | Secured/No damage or missing parts | Table 10.3.1 Electromechanical Releasing Device Inspection | *2 Times/Year | Secured/No damage or missing parts | Table 10.3.1 Suppression System Switches | Inspection | *2 Times/Year | Secured/No damage or missing parts | Table 10.3.1 Fire Alarm Boxes | Inspection | *2 Times/Year | Secured/No damage or missing parts | Table 10.3.1 Heat Detectors | Inspection | *2 Times/Year | Secured/No damage or missing parts | Table 10.3.1 Radiant Energy Fire Detectors Inspection | *Quarterly | No damage/obstructions/proper position | Table 10.3.1 Smoke Detectors | Inspection | *2 Times/Year | Secured/No damage or missing parts | Table 10.3.1 Supervisory Signal Devices Inspection | *Quarterly | Secured/No damage or missing parts | Table 10.3.1 Waterflow Devices Inspection | *Quarterly | Secured/No damage or missing parts | Table 10.3.1 Guard’s Tour Equipment Inspection | *2 Times/Year | No damage or missing parts/equipment | Table 10.3.1 Interface Equipment Inspection | *2 Times/Year | No damage or missing parts/equipment | Table 10.3.1 Alarm Notification Appliances Audible Devices | Inspection | *2 Times/Year | No damage or missing parts/equipment | Table 10.3.1 Speakers | Inspection | *2 Times/Year | No damage or missing parts/equipment | Table 10.3.1 Visible Devices | Inspection | *2 Times/Year | No damage or missing parts/equipment | Table 10.3.1 Supervising Station Fire Alarm Systems - Transmitters DACT | Inspection | 2 Times/Year | Secured/No damage or missing parts | Table 10.3.1 DART | Inspection | 2 Times/Year | Secured/No damage or missing parts | Table 10.3.1 McCulloh | Inspection | 2 Times/Year | Secured/No damage or missing parts | Table 10.3.1 RAT | Inspection | 2 Times/Year | Secured/No damage or missing parts | Table 10.3.1 Supervising Station Fire Alarm Systems - Receivers DACR | Inspection | *Monthly | Secured/No damage or missing parts | Table 10.3.1 DARR | Inspection | 2 Times/Year | Secured/No damage or missing parts | Table 10.3.1 McCulloh | Inspection | 2 Times/Year | Secured/No damage or missing parts | Table 10.3.1 Two-Way RF Multiplex Inspection | 2 Times/Year | Secured/No damage or missing parts | Table 10.3.1 RASSR | Inspection | 2 Times/Year | Secured/No damage or missing parts | Table 10.3.1 RARS | Inspection | 2 Times/Year | Secured/No damage or missing parts | Table 10.3.1 Private Microwave Inspection Inspection | 2 Times/Year | Secured/No damage or missing parts | Table 10.3.1 Engine-Driven Generator Inspection | *Weekly | No damage or leakage | Table 10.3.1 Testing | *Weekly | Verify operation | NFPA 110 Uninterrupted Power Supply (UPS) Testing | *Per manufacturer and NFPA 111 | Table 10.4.4
Inspection: A visual examination to verify an item is in operating condition and free of physical damage.
Testing: A procedure used to determine the status of a system operating as intended by conducting physical checks.
Maintenance: Work performed to keep equipment operable or to make repairs.
* Servicing may be performed by an owner, but must be performed at least annually by a licensed company.
Appendix F - Table 4
Licensed Company Required
Testing, Inspection, and Maintenance of Fire Alarm Signaling Systems
as Required by Regulation 703, Chapter 1 and the National Fire Alarm Code, NFPA 72, 2007 Edition
This brief summary of periodic tests, inspections, and maintenance is not all inclusive, and, to assist in the performance of these services, the user is advised to purchase the applicable documents from NFPA (1-800-344-3555). These periodic services must be performed by a company licensed by the Office of State Fire Marshal, Licensing Division, (302) 739-4394. A log book must be maintained by the licensed company for each system. The log book must include the date the service was performed, the type of service performed, and the person performing the service. An asterisk (*) denotes servicing which may be performed by an owner, but must be performed at least annually (once a year) by a licensed company. A licensed company must forward a Certificate of Inspection to the Office of State Fire Marshal within 30 days of the annual inspection.
Item | Activity | Frequency | Service | Section #/Table Control Equipment Fire Alarm Systems Unmonitored for Alarm Supervisory, Trouble Signals Fuses | Inspection | *Weekly | No damage or missing parts | Table 10.3.1 Testing | Quarterly | Remove fuse & verify rating & supervision | Table 10.4.4 Interfaced Equip | Inspection | *Weekly | Wiring connections secure/No damage | Table 10.3.1 Testing | Quarterly | Verify integrity & signals by operational test | Table 10.4.4 Lamps & LEDs | *Weekly | *Weekly | All lamps and LEDs illuminated | Table 10.3.1 Quarterly | Quarterly | All lamps and LEDs illuminated | Table 10.4.4 Primary (Main) Power Supply | Inspection | *Weekly | Secured/Marked/No damage | Table 10.3.1 Testing | Quarterly | Disconnect secondary power, max load test | Table 10.4.4 Functions | Testing | Quarterly | Full Function Test | Table 10.4.4 Transponders | Testing | Quarterly | Full Function Test | Table 10.4.4 Fire Alarm Systems Monitored for Alarm Supervisory, Trouble Signals Fuses | Inspection | *Weekly | No damage or missing parts | Table 10.3.1 Testing | Quarterly | Remove fuse & verify rating & supervision | Table 10.4.4 Interfaced Equip | Inspection | Annually | No damage or missing parts | Table 10.3.1 Testing | Annually | Verify integrity & signals by operational test | Table 10.4.4 Lamps & LEDs | Inspection | Annually | No damage or missing parts | Table 10.3.1 Testing | Annually | All lamps and LEDs illuminated | Table 10.4.4 Primary (Main) Power Supply | Inspection | Annually | No damage or missing parts | Table 10.3.1 Testing | Annually | Disconnect secondary power, max load test | Table 10.4.4 Functions | Testing | Annually | Full Function Test | Table 10.4.4 Transponders | Testing | Annually | Full Function Test | Table 10.4.4 Batteries Lead-Acid | Inspection | *Monthly | Electrolyte level/connections, No corrosion | Table 10.3.1 Testing | 2 Times/Year | Discharge, Load Voltage, Specific Gravity | Table 10.4.4 Testing | Annually | Charger Test | Table 10.4.4 Nickel-Cadmium | Inspection | 2 Times/Year | No corrosion/leakage, Connections tight | Table 10.3.1 Testing | 2 Times/Year | Load Voltage | Table 10.4.4 Testing | Annually | Charger Test, Discharge (30 min) Test | Table 10.4.4 Primary (Dry Cell) | Inspection | *Monthly | No corrosion/leakage, Connections tight | Table 10.3.1 Testing | Monthly | Load Voltage | Table 10.4.4 Sealed Lead-Acid | Inspection | *2 Times/Year | No corrosion/leakage, Connections tight | Table 10.3.1 Testing | 2 Times/Year | Load Voltage | Table 10.4.4 Testing | Annually | Charger Test, Discharge (30 min) Test | Table 10.4.4 Transient Suppressors Lightning Protection Equipment Inspection | *2 Times/Year | Per mfr/After every lightning strikes/storms | Table 10.3.1 & NFPA 780 Testing | Per mfr and NFPA 780 Remote Annunciators Inspection | *2 Times/Year | Secured/No damage or missing parts | Table 10.3.1 Testing | Annual | Verify operation & identification | Table 10.4.4 Initiating Devices Air Sampling | Inspection | *2 Times/Year | Secured/No damage or missing parts | Table 10.3.1 Testing | Annually | Verify alarm & airflow via ports per mfr | Table 10.4.4 Duct Detectors | Inspection | *2 Times/Year | Secured/No damage or missing parts | Table 10.3.1 Testing | Annually | Verify per manufacturer | Table 10.4.4 Electromechanical Releasing Device Inspection | *2 Times/Year | Secured/No damage or missing parts | Table 10.3.1 Nonrestorable | Testing | Annually | Remove link, ensure operation, lubricate | Table 10.4.4 Restorable | Testing | Annually | Remove link, ensure operation, lubricate | Table 10.4.4 Suppression System Switches Inspection | *2 Times/Year | Secured/No damage or missing parts | Table 10.3.1 Testing | Annually | Mechanical/electrical operation of switch Verify signal receipt at panel | Table 10.4.4 Fire Alarm Boxes | Inspection | *2 Times/Year | Secured/No damage or missing parts | Table 10.3.1 Testing | Annually | Operate per manufacturer | Table 10.4.4 Heat Detectors/All | Inspection | *2 Times/Year | Secured/No damage or missing parts | Table 10.3.1 Fixed-Temp | Testing | Annually | Heat test per manufacturer | Table 10.4.4 Rate-of-Rise, Rate-of-Compensation, Restorable Line, Spot Type (excluding Pneumatic Tub Type) Fixed-Temp Testing | Annually | Mechanical/electrical tests/Loop resistance | Table 10.4.4 Nonrestorable Line Type Fixed-Temp. Testing | After 15 Years | Replace all devices or Lab test 2 per 100 | Table 10.4.4 Nonrestorable Spot Type Testing | Annually | Mechanical/electrical function tests | Table 10.4.4 (General) Restorable Line Testing | Annually | Heat source or pressure pump | Table 10.4.4 Radiant Energy Fire Detectors Inspection | *Quarterly | No damage/obstructions/proper position | Table 10.3.1 Testing | 2 Times/Year | Per manufacturer and Sensitivity Tests | Table 10.4.4 Smoke Detectors | Inspection | *2 Times/Year | Secured/No damage or missing parts | Table 10.3.1 Testing | Annually | Functional Test | Table 10.4.4 Testing | 1st Year and Alternating Yrs Sensitivity Test | (IF within listed and marked sensitivity range) | Table 10.4.4 Supervisory Signal Devices Inspection | *Quarterly | Secured/No damage or missing parts | Table 10.3.1 Control Valve | Testing | Quarterly | Operate valve per mfr/Verify signal receipt | Table 10.4.4 High-/Low-Air | Testing | Quarterly | Operate valve per mfr/Verify signal receipt | Table 10.4.4 Room Temp | Testing | Quarterly | Operate switch/Verify signal receipt | Table 10.4.4 Water Level | Testing | Quarterly | Operate switch/Verify signal receipt | Table 10.4.4 Water Temp | Testing | Quarterly | Operate switch/Verify signal receipt | Table 10.4.4 Water Flow | Testing | Quarterly | Flow water per NFPA 25 | Table 10.4.4 Valve Tamper Sw | Testing | 2 Times/Year | Operate switch per mfr/Verify signal receipt | Table 10.4.4 Waterflow Devices Inspection | *Quarterly | Secured/No damage or missing parts | Table 10.3.1 Testing | 2 Times/Year | Operate switch per mfr/Verify signal receipt | Table 10.4.4 Fire-Gas & Other | Testing | Annually | Per manufacturer | Table 10.4.4 Guard’s Tour Equipment Inspection | *2 Times/Year | No damage or missing parts/equipment | Table 10.3.1 Testing | Annual | Per manufacturer | Table 10.4.4 Interface Equipment Inspection | *2 Times/Year | Secured/No damage or missing parts | Table 10.3.1 Testing | Annual | Operational test/Verify signal receipt | Table 10.4.4 Alarm Notification Appliances Audible Devices | Inspection | *2 Times/Year | Secured/No damage or missing parts | Table 10.3.1 Testing | Annual | Measure sound level IAW ANSI S-1.4a | Table 10.4.4 Speakers | Inspection | *2 Times/Year | Secured/No damage or missing parts | Table 10.3.1 Testing | Annual | Measure sound level IAW ANSI S-1.4a Verify Voice Clarity | Table 10.4.4 Visible Devices | Inspection | *2 Times/Year | Secured/No damage or missing parts | Table 10.3.1 Testing | Annual | Per manufacturer | Table 10.4.4 Supervising Station Fire Alarm Systems - Transmitters All Equipment | Testing | Annual | Per mfr/operational test/verify signal receipt | Table 10.4.4 DACT | Inspection | *2 Times/Year | Secured/No damage or missing parts | Table 10.3.1 Testing | Annual | 2 lines/line seizure/trouble signal w/in 90 sec | Table 10.4.4 DART | Inspection | *2 Times/Year | Secured/No damage or missing parts | Table 10.3.1 Testing | Annual | 3 rounds-3 impulses/end-end metallic/etc | Table 10.4.4 McCulloh | Inspection | *2 Times/Year | Secured/No damage or missing parts | Table 10.3.1 Testing | Annual | 2 lines/line seizure/trouble signal w/in 90 sec | Table 10.4.4 RAT | Inspection | *2 Times/Year | Secured/No damage or missing parts | Table 10.3.1 Testing | Annual | Fault indication/trouble signal | Table 10.4.4 Supervising Station Fire Alarm Systems - Receivers All Equipment | Testing | Monthly | Per mfr/operational test/verify signal receipt | Table 10.4.4 DACR | Inspection | *Monthly | Secured/No damage or missing parts | Table 10.3.1 Testing | Annual | Trouble signal/verify 24-hour signals | Table 10.4.4 DARR | Inspection | *2 Times/Year | Secured/No damage or missing parts | Table 10.3.1 Testing | Monthly | Verify signals for all 4 trouble conditions/etc | Table 10.4.4 McCulloh | Inspection | *2 Times/Year | Secured/No damage or missing parts | Table 10.3.1 Testing | Annual | 2 lines/line seizure/trouble signal w/in 90 sec | Table 10.4.4 Two-Way RF Multiplex Inspection | *2 Times/Year | Secured/No damage or missing parts | Table 10.3.1 Testing | Monthly | Per mfr/operational test/verify signal receipt | Table 10.4.4 RASSR & RARSR | Inspection | *2 Times/Year | Secured/No damage or missing parts | Table 10.3.1 Testing | Monthly | Verify signals for all 3 trouble conditions | Table 10.4.4 Private Microwave Inspection | *2 Times/Year | Secured/No damage or missing parts | Table 10.3.1 Testing | Monthly | Verify signals for all 4 trouble conditions/etc | Table 10.4.4 Engine-Driven Generator Inspection | *Weekly | No damage or leakage | Table 10.3.1 Testing | *Weekly | Verify operation | NFPA 110 Uninterrupted Power Supply (UPS) Testing | *Per manufacturer and NFPA 111 | Table 10.4.4 Secondary (Standby) Power Supply Testing | Annually | Disconnect primary/verify trouble signal/etc | Table 10.4.4 Control Panel Trouble Signals Testing | Annually | Audible/Visible, Disconnect Switches, Ground-Faults, Signal Transmission Off-Site | Table 10.4.4 Conductors Metallic | Testing | Annually | Stray Voltage, Short Circuit Faults, Ground Faults, Loop Resistance | Table 10.4.4 Nonmetallic Fiber Optics/Fiber Optics Cable Power Testing | Annually | Circuit Integrity, Supervision | Table 10.4.4 Emergency Voice/Alarm Communications Equipment Inspection | Annually | No damage or missing parts | Table 10.3.1 Phone Set, Phone Jacks, Amplifier/Tone Generators, Call-In Signal Silence, Off-Hook Indicator (Ring Down), System Performance Testing | Annually | Full Function Test | Table 10.4.4 Special Hazard Equipment Abort Switches, Cross-Zone Detection Circuits Matrix-Type Circuit, Release Solenoid, Squibb Release Circuit, Verified/Sequential/Counting Zone Circuit, All other devices or circuits or combinations thereof. Testing | Annually | Operate switches/sensors and verify | Table 10.4.4 Special Procedures Inspection | 2 Times/Year | No damage or missing parts | Table 10.3.1 Testing | Annually | Alarm Verification/Multiplex Systems | Table 10.4.4 Low Power Radio (Wireless Systems) Testing | Monthly | Per manufacturer | Table10.4.4
Inspection: A visual examination to verify an item is in operating condition and free of physical damage.
Testing: A procedure used to determine the status of a system operating as intended by conducting physical checks.
Maintenance: Work performed to keep equipment operable or to make repairs.
* Servicing may be performed by an owner, but must be performed at least annually by a licensed company
29 DE Reg. 931 (05/01/26)